Rinnai i-Series+ 140 — Heat Exchanger Overheat
140
Heat Exchanger Overheat. The overheat switch has tripped, so check for scale buildup, pump lockup, closed CH valves, and freezing conditions.
Applies to
This overheating code is displayed by the i-Series+ front-panel control on i-Series+ combi models up to 150K BTU (IP060160C, IP090099C, IP090199C, IP120199C, IP150199C), as documented in Installation and Operation Manual, doc 800000190 — i-Series+ 150K BTU and smaller combi boilers (hosted on the Rinnai Canada IP060160C product page) (800000190 (02)). Codes can differ between controller generations, so always check the manual that matches your unit.
- Rinnai i-Series+ Combi
- Rinnai IP060160C
- Rinnai IP090099C
- Rinnai IP090199C
- Rinnai IP120199C
- Rinnai IP150199C
- Rinnai IP175199C
- Rinnai IP199199C
Controller: i-Series+ front-panel control. Source manual: 800000190 (02) (2024-10).
Why a code is not a diagnosis
An over-temperature code protects the heat exchanger or venting; it does not reveal whether the cause is low water flow, a failed pump, trapped air, fouling or a sensor fault.
Safe things to observe
- Note the code and whether rooms or hot water are still working.
- If you see steam, melted wiring or smell burning, switch the appliance off at its service switch and call a technician.
Do not
- Do not reset the appliance repeatedly while the cause is unknown.
- Do not remove covers or bypass any high-limit device.
How professional service helps
- A technician checks pump operation, flow, system pressure and the cleanliness of the heat exchanger.
- Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Heat exchanger
The heat exchanger is where a boiler transfers heat from the burner flame to the water that heats your home.
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
- Gas Boiler Replacement
ROMA replaces old, failed or inefficient gas boilers in Greater Vancouver, handling removal, venting and gas-supply changes,…
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for Rinnai i-Series+ Combi.
Frequently asked questions
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Installation and Operation Manual, doc 800000190 — i-Series+ 150K BTU and smaller combi boilers (hosted on the Rinnai Canada IP060160C product page) · 800000190 (02) · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.