Rinnai's Canadian I-Series+ combis put space heating and on-demand domestic hot water in one wall-hung condensing appliance: the five models up to 150 MBH input (IP060160C through IP150199C) are documented here in full from the EN I&O manual 800000190(02), and the two larger combis (IP175199C, IP199199C) are on rinnai.ca but only as draft models here, because their I&O content is raster-only pending review.

Current seriesSold in CanadaNatural gasPropaneresidential

Series facts

Type
combi
Efficiency
96% AFUE
Fuel
Natural gas or propane per the manual; units ship configured for natural gas and gas-supply pressure is NG 3.5-10.5 in. W.C. or propane 8.0-13.5 in. W.C. per spec Table 2.
Venting
Vent connection is 2" nominal PVC/polypropylene (twin pipe) or 3" x 5" concentric, with direct-vent and room-air options; maximum equivalent lengths are per model in the I&O manual (Tables 17 and 20), so the manual for the specific model governs — IP090099C, for example, allows 100 equivalent ft in 2" below 2,000 ft elevation.
Models documented
7

"Up to 96% AFUE" per Rinnai Canada marketing copy on the I-SERIES+ pages and the Canadian brochure. The I&O manual spec tables print no AFUE figure and no per-model rating is published, so this is the manufacturer's claim, not a measured per-model figure.

About the i-Series+ Combi

The I-Series+ combi is the Canadian version of Rinnai's current residential combination boiler: one wall-hung, indoor, gas-fired condensing appliance that heats the building and produces domestic hot water on demand with no storage tank. Model codes read CH input first, then DHW input: IP060160C means a 60,000 BTU/h central-heating input with a 160,000 BTU/h DHW input, and the DHW side is larger than the heating side on every model except IP090099C, where both sides are 90 MBH and 99 MBH.

Five combis up to 150 MBH input are covered in full here — IP060160C, IP090099C, IP090199C, IP120199C and IP150199C — with specifications and input figures from the English I&O manual, doc 800000190(02) (10/2024), section 3.4 Table 2. All five fire down to a 15,000 BTU/h minimum input, carry Canadian CRN 2089.9CL certification, and are CSA/ANSI Z21.13 and CSA 4.9 listed. A sixth code, IP090160C, appears in the manual's model lists but is not on the rinnai.ca sales grid.

The two larger combis, IP175199C and IP199199C (175,000 and 199,000 BTU/h CH input with 199,000 BTU/h DHW), are sold in Canada — product pages carry a 2024 launch and French documentation — but their English I&O manual on rinnai.ca is raster-only, so Boilers.ca documents them as draft models pending review of the scanned text rather than publishing spec figures as final.

The control shows fault codes as plain numbers or letters (021, 110, LC, FFF, SS) with no E prefix, and section 12.11 of the I&O manual prints the full table with combi-only rows such as 021 (too-long DHW continuous operation), 651 (water flow control) and 661 (by-pass) marked. Parameter 08 selects whether the boiler permits DHW priority or simultaneous central-heating and DHW operation, and the same control family's codes must be read from the boiler manuals because Rinnai tankless heaters share short numeric code styles but not code tables.

Highlights

  • Canadian combi codes read CH input / DHW input: IP060160C = 60 MBH CH with 160 MBH DHW
  • Five models to 150 MBH input documented from EN I&O manual 800000190(02) (10/2024)
  • 15,000 BTU/h minimum input across the series; CRN 2089.9CL (Canada)
  • IP175199C and IP199199C sold in Canada but draft-only here (raster I&O manual)
  • Codes print without an E prefix (021, 110, LC, FFF, SS); combi-only rows marked in the manual
  • Parameter 08 sets DHW priority or simultaneous CH + DHW operation

Rinnai Limited Warranty (I&O manual warranty section, Table 56): 12-year heat exchanger, 5-year parts and components, and 1-year reasonable labour for residential applications in the US and Canada, first installation site only; registration within 90 days serves as proof of purchase.

Models

i-Series+ Combi models

One canonical page per model with input, output and efficiency kept separate.

CurrentSold in Canada
Input
15–60 MBH
Output (max)
AFUE
96 %

The Rinnai IP060160C is the smallest I-Series+ combi: 15 to 60 MBH central-heating input with DHW input to 160 MBH and 7.9 GPM maximum hot-water flow in one wall-hung condensing appliance, rated up to 96% AFUE in Rinnai's Canadian marketing.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–90 MBH
Output (max)
AFUE
96 %

The Rinnai IP090099C is the I-Series+ combi with the closest CH/DHW pair: 15 to 90 MBH heating input and a 99 MBH DHW input (5.3 GPM maximum flow), rated up to 96% AFUE in Rinnai's Canadian marketing.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–90 MBH
Output (max)
AFUE
96 %

The Rinnai IP090199C pairs a 90 MBH heating input with a 199 MBH DHW input: 15 to 90 MBH central heating plus near-tankless hot-water headroom in the small 73 lb chassis, rated up to 96% AFUE in Rinnai's Canadian marketing.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–120 MBH
Output (max)
AFUE
96 %

The Rinnai IP120199C lifts heating to 120 MBH of input while keeping the 199 MBH DHW side: 15 to 120 MBH central heating with 9.8 GPM maximum hot-water flow, in the heavier 76.1 lb small chassis.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–150 MBH
Output (max)
AFUE
96 %

The Rinnai IP150199C is the top of the fully documented I-Series+ combi range: 15 to 150 MBH central-heating input with a 199 MBH DHW side (9.8 GPM maximum), the largest small-chassis combi at 76.1 lb.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–175 MBH
Output (max)
AFUE
96 %

The Rinnai IP175199C is the 175k I-Series+ combi — 175 MBH of central-heating input with a 199 MBH DHW side on the large chassis, documented from the EN 175k+ combi I&O manual at 123.5 lb. It is named in Health Canada recall RA-77507.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–199 MBH
Output (max)
AFUE
96 %

The Rinnai IP199199C is the top I-Series+ combi — 199 MBH of central-heating input with a 199 MBH DHW side on the large chassis, documented from the EN 175k+ combi I&O manual at 123.5 lb. It is named in Health Canada recall RA-77507.

Natural gasPropaneCombi

Compare models in this series

Comparison of Rinnai IP060160C and Rinnai IP090099C and Rinnai IP090199C and Rinnai IP120199C and Rinnai IP150199C and Rinnai IP175199C and Rinnai IP199199C
SpecificationRinnai IP060160CRinnai IP090099CRinnai IP090199CRinnai IP120199CRinnai IP150199CRinnai IP175199CRinnai IP199199C
Heating input, minimum15 MBH15 MBH15 MBH15 MBH15 MBH15 MBH15 MBH
Heating input, maximum60 MBH90 MBH90 MBH120 MBH150 MBH175 MBH199 MBH
output-max
Efficiency (AFUE)96 %96 %96 %96 %96 %96 %96 %
turndown
Max. equivalent vent length, 3"160 ft160 ft160 ft160 ft160 ft
Max. equivalent vent length, 2"75 ft100 ft75 ft75 ft75 ft75 ft
Weight73 lb73 lb73 lb76.1 lb76.1 lb123.5 lb123.5 lb

Read the full comparison: Rinnai IP060160C vs IP090099C

Read the full comparison: Rinnai IP090099C vs IP090199C

Read the full comparison: Rinnai IP090199C vs IP120199C

Read the full comparison: Rinnai IP120199C vs IP150199C

Read the full comparison: Navien NCB-250/150H vs Rinnai IP150199C

Error codes and alerts

i-Series+ Combi alerts

  • 021i-Series+ front-panel control
  • 100i-Series+ front-panel control
  • 110i-Series+ front-panel control
  • 120i-Series+ front-panel control
  • 140i-Series+ front-panel control
  • 150i-Series+ front-panel control
  • 161i-Series+ front-panel control
  • 170i-Series+ front-panel control
  • 180i-Series+ front-panel control
  • 190i-Series+ front-panel control
  • 210i-Series+ front-panel control
  • 220i-Series+ front-panel control
  • 250i-Series+ front-panel control
  • 303i-Series+ front-panel control
  • 310i-Series+ front-panel control
  • 321i-Series+ front-panel control
  • 331i-Series+ front-panel control
  • 341i-Series+ front-panel control
  • 353i-Series+ front-panel control
  • 363i-Series+ front-panel control
  • 380i-Series+ front-panel control
  • 393i-Series+ front-panel control
  • 400i-Series+ front-panel control
  • 430i-Series+ front-panel control
  • 443i-Series+ front-panel control
  • 520i-Series+ front-panel control
  • 540i-Series+ front-panel control
  • 610i-Series+ front-panel control
  • 631i-Series+ front-panel control
  • 651i-Series+ front-panel control
  • 661i-Series+ front-panel control
  • 670i-Series+ front-panel control
  • 681i-Series+ front-panel control
  • 700i-Series+ front-panel control
  • 710i-Series+ front-panel control
  • 720i-Series+ front-panel control
  • 763i-Series+ front-panel control
  • 890i-Series+ front-panel control
  • LCi-Series+ front-panel control
  • FFFi-Series+ front-panel control
  • SSi-Series+ front-panel control
  • SEi-Series+ front-panel control
  • 021i-Series+ front-panel control
  • 100i-Series+ front-panel control
  • 120i-Series+ front-panel control
  • 140i-Series+ front-panel control
  • 150i-Series+ front-panel control
  • 210i-Series+ front-panel control
  • 250i-Series+ front-panel control
  • 303i-Series+ front-panel control
  • 321i-Series+ front-panel control
  • 331i-Series+ front-panel control
  • 353i-Series+ front-panel control
  • 380i-Series+ front-panel control
  • 393i-Series+ front-panel control
  • 400i-Series+ front-panel control
  • 430i-Series+ front-panel control
  • 443i-Series+ front-panel control
  • 520i-Series+ front-panel control
  • 540i-Series+ front-panel control
  • 631i-Series+ front-panel control
  • 650i-Series+ front-panel control
  • 670i-Series+ front-panel control
  • 700i-Series+ front-panel control
  • 720i-Series+ front-panel control
  • 763i-Series+ front-panel control
  • 890i-Series+ front-panel control
  • LCi-Series+ front-panel control
  • FFFi-Series+ front-panel control
  • 55i-Series+ front-panel control

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

How do I read a model number like IP090199C?

The two numbers are the central-heating input and the domestic hot water input in BTU/h: IP090199C fires up to 90,000 BTU/h for space heating and up to 199,000 BTU/h while making hot water. The trailing C marks the combi line on rinnai.ca.

Why is only part of the combi line documented on Boilers.ca?

The five combis up to 150 MBH input have a full English I&O manual with a readable text layer, so their records are published. The IP175199C and IP199199C manuals are raster-only scans at this time, so those two models are held as drafts until a reviewer verifies the scanned text.

Does the combi run heating and hot water at the same time?

It can. Parameter 08 selects between permitting DHW priority and simultaneous central-heating and DHW operation, and parameter 18 sets the maximum continuous DHW running time in either mode. Installation parameters are set by a licensed professional.