Rinnai IP199199C

The Rinnai IP199199C is the top I-Series+ combi — 199 MBH of central-heating input with a 199 MBH DHW side on the large chassis, documented from the EN 175k+ combi I&O manual at 123.5 lb. It is named in Health Canada recall RA-77507.

CurrentSold in Canada

Key figures

Max input
199 MBH
Max CSA output
AFUE
96 %
Min input
15 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Rinnai IP199199C in practice

The IP199199C is the largest I-Series+ combi: both sides of the appliance fire to 199,000 BTU/h, giving the line its maximum central-heating and domestic-hot-water reach. Weight and height come from the EN I&O manual spec table — 123.5 lb (56 kg) and a 34.88 in body height (37.87 in or 40.67 in overall with fittings) — against a product page that prints 64 lb and 45.3 in; both conflicts are recorded on the spec rows rather than resolved silently. The 9.8 GPM maximum DHW flow is printed on the product page and in the manual spec table alike.

This model is named in Health Canada recall RA-77507 (updated 2025-06-05): units sold between September 2024 and February 2025 with serial numbers beginning in S may have a boiler door that fails to seal, a carbon-monoxide hazard, and Health Canada directs owners to a free repair through Rinnai America at 800-621-9419.

Best suited to

  • The largest central-heating loads the I-Series+ combi line serves, to 199 MBH of input
  • Owners who want maximum heating and hot-water reach from one wall-hung appliance
  • Large homes where an IP150199C or IP175199C would be undersized on the heating side

Applicability and support

Model number
IP199199C
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Rinnai. Units are shown with every value; notes flag conflicting sources or missing figures.

Rinnai IP199199C specifications
SpecificationValueNote
Input
Heating input, minimum15 MBH15,000 BTU/h minimum input; printed on the product page and in the EN I&O manual spec table.
Heating input, maximum199 MBHCentral-heating maximum input per the EN I&O manual spec table; the product page prints a 199,000 BTU/h maximum that does not split CH/DHW.
Efficiency
Efficiency (AFUE)96 %Up to 96% AFUE per Rinnai Canada marketing copy and the Canadian brochure; no per-model AFUE figure is printed in the I&O manual spec tables.
Domestic hot water
DHW input, maximum199 MBH199,000 BTU/h per the product page and the EN I&O manual spec table.
Maximum DHW flow rate9.8 GPM9.8 GPM (37 L/min) per the product page and the EN I&O manual spec table; 5.1 GPM at a 70°F rise per the manual.
Domestic hot waterOn demand inside the combiDHW input and flow figures above; DHW temperature setting range 98°F-140°F (37°C-60°C) per spec Table 2.
Venting and air
Venting2" nominal PVC/polypropylene or 3" x 5" concentricVent connection per the I&O manual; direct-vent (concentric or twin-pipe) and room-air options are covered in the manual's venting section.
Max. equivalent vent length, 2"75 ftTwin-pipe 2" maximum equivalent length per the 175k+ combi I&O manual (Table 20).
Max. equivalent vent length, 3"160 ftTwin-pipe 3" maximum equivalent length per the 175k+ combi I&O manual (Table 20).
Physical and connections
Weight123.5 lb123.5 lb (56 kg) per the EN I&O manual spec table. The product page prints 64 lb (29.09 kg) — a page/manual discrepancy; the manual figure is used here.
Water content (CH)2.4 galCentral-heating water content per spec Table 2.
Gas connection3/4" NPTPer spec Table 3.
Heating water connections1" NPTCH supply and return per spec Table 3.
DHW connections3/4" NPTDHW cold inlet and hot outlet per spec Table 3.
Width19.45 in (494 mm)Per the I&O manual dimension figure and the product page.
Depth15.48 in (393.3 mm)Per the I&O manual dimension figure and the product page.
Operating limits and other
FuelNatural gas or propaneGas supply pressure per spec Table 2: NG 3.5-10.5 in. W.C. (0.87-2.61 kPa); propane 8.0-13.5 in. W.C. (1.99-3.36 kPa).
CH water pressure13 – 45 psiCH pressure per the EN I&O manual spec table for 175k+ combis: minimum 13 PSI, maximum 55 PSI (379 kPa); recommended 17-26 PSI; 30 PSI relief valve included.

Frequently asked questions

What does IP199199C mean?

Central-heating input over DHW input, both 199,000 BTU/h — the maximum rating in the I-Series+ combi line.

Is the IP199199C affected by a recall?

Yes — Health Canada recall RA-77507 covers the IP199199C, IP175199C, IP175S and IP199S sold between September 2024 and February 2025 with S-prefix serial numbers. Follow the Health Canada alert for the free repair process.

What is this model's maximum DHW flow?

9.8 GPM (37 L/min) per the product page and the EN I&O manual spec table, with 5.1 GPM at a 70°F rise per the manual.

Questions about the Rinnai IP199199C?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.