Skip to content
Boilers.caby ROMA Heating & Cooling

Rinnai · i-Series+ Combi

Rinnai IP060160C

The Rinnai IP060160C is the smallest I-Series+ combi: 15 to 60 MBH central-heating input with DHW input to 160 MBH and 7.9 GPM maximum hot-water flow in one wall-hung condensing appliance, rated up to 96% AFUE in Rinnai's Canadian marketing.

CurrentSold in Canada

Key figures

Max input
60 MBH
Max CSA output
AFUE
96 %
Min input
15 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Rinnai IP060160C in practice

The IP060160C is Rinnai's entry I-Series+ combi: a wall-hung condensing boiler that heats from 15,000 to 60,000 BTU/h of input and fires up to 160,000 BTU/h for on-demand domestic hot water at up to 7.9 GPM. It is the smallest of the five combis documented in full on Boilers.ca, with specifications from the English I&O manual, doc 800000190(02) (10/2024).

Weighing 73 lb in the small chassis (18.5 in wide, 11.5 in deep), the unit carries 0.75 gal of CH water and includes a 30 PSI CH pressure relief valve; venting is 2" PVC/polypropylene twin pipe (75 equivalent ft maximum) or the 3" x 5" concentric option, and supply connections are 3/4" NPT gas and DHW with 1" NPT heating connections.

Rinnai Canada's I-Series+ marketing claims up to 96% AFUE for the family; the manual's spec table prints no per-model AFUE figure, so the rating shown here is the manufacturer's claim. Central heating setpoint ranges 86°F-180°F and DHW 98°F-140°F per spec Table 2.

Best suited to

  • Homes whose heat-loss calculation fits under 60 MBH of central-heating input
  • Households wanting on-demand domestic hot water without a separate tank
  • Compact mechanical rooms: the 18.5 x 11.5 in chassis hangs on a wall

Applicability and support

Model number
IP060160C
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Rinnai. Units are shown with every value; notes flag conflicting sources or missing figures.

Rinnai IP060160C specifications
SpecificationValueNote
Input
Heating input, minimum15 MBHSpace-heating input; 15,000 BTU/h minimum input per spec Table 2.
Heating input, maximum60 MBHSpace-heating (CH) maximum input per spec Table 2.
Efficiency
Efficiency (AFUE)96 %Up to 96% AFUE per Rinnai Canada marketing copy and the Canadian brochure; no per-model AFUE figure is printed in the I&O manual spec tables.
Domestic hot water
DHW input, maximum160 MBH160,000 BTU/h maximum DHW input per spec Table 2.
Maximum DHW flow rate7.9 GPM7.9 GPM (30 L/min) per spec Table 2; 4.1 GPM at a 70°F rise. The product page lists 7.9 GPM.
Domestic hot waterOn demand inside the combiDHW input and flow figures above; DHW temperature setting range 98°F-140°F (37°C-60°C) per spec Table 2.
Venting and air
Venting2" nominal PVC/polypropylene or 3" x 5" concentricVent connection per the I&O manual; direct-vent (concentric or twin-pipe) and room-air options are covered in the manual's venting section.
Max. equivalent vent length, 2"75 ftTwin-pipe 2" PVC / 2" PP maximum equivalent length per the I&O manual (Table 20).
Physical and connections
Weight73 lb73.0 lb (33 kg) per the I&O manual spec Table 2; the product page lists 73 lb (33.11 kg).
Water content (CH)0.75 galCentral-heating water content per spec Table 2.
Gas connection3/4" NPTPer spec Table 3.
Heating water connections1" NPTCH supply and return per spec Table 3.
DHW connections3/4" NPTDHW cold inlet and hot outlet per spec Table 3.
Width18.5 in (470 mm)Per the I&O manual dimension figure and the product page.
Depth11.5 in (291 mm)Per the I&O manual dimension figure; the product page lists 292.1 mm.
Operating limits and other
FuelNatural gas or propaneGas supply pressure per spec Table 2: NG 3.5-10.5 in. W.C. (0.87-2.61 kPa); propane 8.0-13.5 in. W.C. (1.99-3.36 kPa).
CH water pressure13 – 45 psiMinimum 13 PSI (90 kPa), maximum 45 PSI (310 kPa); recommended 17-26 PSI; 30 PSI pressure relief valve included with the system (spec Table 2).

Frequently asked questions

What does IP060160C mean?

The code reads CH input over DHW input: 60,000 BTU/h for central heating and 160,000 BTU/h for domestic hot water. The product page describes it as "CH 60k / DHW 160k".

How much hot water can the IP060160C deliver?

Up to 7.9 GPM maximum DHW flow per the I&O manual spec table (4.1 GPM at a 70°F temperature rise), with DHW input reaching 160,000 BTU/h. Delivery depends on incoming water temperature.

Is the IP060160C vented in PVC?

Yes. The vent connection is 2" nominal PVC or polypropylene, with a maximum equivalent length of 75 ft in 2" twin-pipe per the I&O manual; a 3" x 5" concentric option is also listed.

Questions about the Rinnai IP060160C?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate