Rinnai IP175199C
The Rinnai IP175199C is the 175k I-Series+ combi — 175 MBH of central-heating input with a 199 MBH DHW side on the large chassis, documented from the EN 175k+ combi I&O manual at 123.5 lb. It is named in Health Canada recall RA-77507.
Key figures
- Max input
- 175 MBH
- Max CSA output
- —
- AFUE
- 96 %
- Min input
- 15 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Rinnai IP175199C in practice
The IP175199C is the first of the two large-chassis I-Series+ combis, fired to 175,000 BTU/h for central heating and 199,000 BTU/h for domestic hot water. Rinnai Canada's product page and the English I&O manual disagree on three published figures, and Boilers.ca records each conflict on the spec row rather than resolving it silently: the manual spec table prints 123.5 lb (56 kg) and a 34.88 in body height (37.87 in or 40.67 in overall with fittings) where the page prints 64 lb and 45.3 in, and the manual's 9.8 GPM maximum DHW flow (5.1 GPM at a 70°F rise) appears as 7.9 GPM on the page.
This model is named in Health Canada recall RA-77507 (updated 2025-06-05): IP175199C units sold between September 2024 and February 2025 with serial numbers beginning in S may have a boiler door that fails to seal, a carbon-monoxide hazard; Health Canada directs owners to a free repair through Rinnai America at 800-621-9419. Product-page copy dates the 175k+ Canadian launch to 2024.
Best suited to
- Homes whose heat-loss calculation approaches 175 MBH of central-heating input
- Households wanting the large-chassis combi: 199 MBH of DHW headroom beside a 175 MBH heating side
- Owners who need more heating reach than the 150 MBH small-chassis combis provide
Applicability and support
- Model number
- IP175199C
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Rinnai. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 15 MBH | 15,000 BTU/h minimum input; printed on the product page and in the EN I&O manual spec table. |
| Heating input, maximum | 175 MBH | Central-heating maximum input per the EN I&O manual spec table; the product page prints only a 199,000 BTU/h maximum without splitting CH/DHW. |
| Efficiency | ||
| Efficiency (AFUE) | 96 % | Up to 96% AFUE per Rinnai Canada marketing copy and the Canadian brochure; no per-model AFUE figure is printed in the I&O manual spec tables. |
| Domestic hot water | ||
| DHW input, maximum | 199 MBH | 199,000 BTU/h per the product page and the EN I&O manual spec table. |
| Maximum DHW flow rate | 9.8 GPM | 9.8 GPM (37 L/min) per the EN I&O manual spec table (5.1 GPM at a 70°F rise per the manual). The product page prints 7.9 GPM — a page/manual discrepancy; the manual figure is used here. |
| Domestic hot water | On demand inside the combi | DHW input and flow figures above; DHW temperature setting range 98°F-140°F (37°C-60°C) per spec Table 2. |
| Venting and air | ||
| Venting | 2" nominal PVC/polypropylene or 3" x 5" concentric | Vent connection per the I&O manual; direct-vent (concentric or twin-pipe) and room-air options are covered in the manual's venting section. |
| Max. equivalent vent length, 2" | 75 ft | Twin-pipe 2" maximum equivalent length per the 175k+ combi I&O manual (Table 20). |
| Max. equivalent vent length, 3" | 160 ft | Twin-pipe 3" maximum equivalent length per the 175k+ combi I&O manual (Table 20). |
| Physical and connections | ||
| Weight | 123.5 lb | 123.5 lb (56 kg) per the EN I&O manual spec table. The product page prints 64 lb (29.09 kg) — a page/manual discrepancy; the manual figure is used here. |
| Water content (CH) | 2.4 gal | Central-heating water content per spec Table 2. |
| Gas connection | 3/4" NPT | Per spec Table 3. |
| Heating water connections | 1" NPT | CH supply and return per spec Table 3. |
| DHW connections | 3/4" NPT | DHW cold inlet and hot outlet per spec Table 3. |
| Width | 19.45 in (494 mm) | Per the I&O manual dimension figure and the product page. |
| Depth | 15.48 in (393.3 mm) | Per the I&O manual dimension figure and the product page. |
| Operating limits and other | ||
| Fuel | Natural gas or propane | Gas supply pressure per spec Table 2: NG 3.5-10.5 in. W.C. (0.87-2.61 kPa); propane 8.0-13.5 in. W.C. (1.99-3.36 kPa). |
| CH water pressure | 13 – 45 psi | CH pressure per the EN I&O manual spec table for 175k+ combis: minimum 13 PSI, maximum 55 PSI (379 kPa); recommended 17-26 PSI; 30 PSI relief valve included. |
Alerts documented for this model
Frequently asked questions
Why does Boilers.ca list 123.5 lb when the Rinnai page says 64 lb?
The EN I&O manual spec table prints 123.5 lb (56 kg) for the IP175199C and the product page prints 64 lb (29.09 kg). Boilers.ca uses the manual figure and records the page value as a documented discrepancy rather than silently dropping it — the page's 45.3 in height likewise differs from the manual's 34.88 in body height.
Is the IP175199C affected by a recall?
Yes — Health Canada recall RA-77507 covers the IP175199C, IP199199C, IP175S and IP199S sold between September 2024 and February 2025 with S-prefix serial numbers. Follow the Health Canada alert for the free repair process.
Which chassis does the IP175199C use?
The large I-Series+ chassis: 19.45 in wide and 15.48 in deep per the product page and the manual, with the body height at 34.88 in per the manual (the page lists 45.3 in).
Questions about the Rinnai IP175199C?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Rinnai Canada — IP175199C product page · accessed September 7, 2026
- Health Canada — Rinnai i-Series Plus Boilers recalled due to poisoning hazard (RA-77507) · accessed September 7, 2026
Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.