Viessmann Vitodens 100-W F.446 — Burner in a Fault State
F.446
Burner in a fault state. A deviation has occurred at the boiler supply temperature sensor or high limit safety cut-out; check the sensor, its plug-in connection and lead, then reset the boiler.
Applies to
This overheating code is displayed by the HMU-BCU control (3.5" display) on Vitodens 100-W B1HE heating-only and B1KE combi models (B1HE-85, B1HE-120, B1HE-150, B1HE-199, B1KE-120, B1KE-199), as documented in Installation and Service Instructions — Vitodens 100-W B1HE/B1KE, doc 6167 818 - 22, troubleshooting fault messages (6167 818 - 22). Codes can differ between controller generations, so always check the manual that matches your unit.
- Viessmann Vitodens 100-W (B1HE / B1KE)
- Viessmann Vitodens 100-W B1HE-85
- Viessmann Vitodens 100-W B1HE-120
- Viessmann Vitodens 100-W B1HE-150
- Viessmann Vitodens 100-W B1HE-199
- Viessmann Vitodens 100-W B1KE-120
- Viessmann Vitodens 100-W B1KE-199
Controller: HMU-BCU control (3.5" display). Source manual: 6167 818 - 22 (2026-02).
Why a code is not a diagnosis
An over-temperature code protects the heat exchanger or venting; it does not reveal whether the cause is low water flow, a failed pump, trapped air, fouling or a sensor fault.
Safe things to observe
- Note the code and whether rooms or hot water are still working.
- If you see steam, melted wiring or smell burning, switch the appliance off at its service switch and call a technician.
Do not
- Do not reset the appliance repeatedly while the cause is unknown.
- Do not remove covers or bypass any high-limit device.
How professional service helps
- A technician checks pump operation, flow, system pressure and the cleanliness of the heat exchanger.
- Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Burner assembly
The burner assembly is where gas and air meet and burn inside a boiler, and its condition decides whether combustion is clean or makes carbon…
What a technician checks →High-limit switch
A high-limit switch shuts the burner off when boiler water gets hotter than it should, protecting the heat exchanger and the system from overheating.
What a technician checks →Boiler sensors (thermistors)
Boiler sensors are small temperature probes, usually thermistors, that tell the control how hot the water and flue gases are so it can fire safely…
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for Viessmann Vitodens 100-W (B1HE / B1KE).
Frequently asked questions
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Installation and Service Instructions — Vitodens 100-W B1HE/B1KE, doc 6167 818 - 22, troubleshooting fault messages · 6167 818 - 22 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.