Skip to content
Boilers.caby ROMA Heating & Cooling

Viessmann · Vitodens 100-W (B1HE / B1KE)

Viessmann Vitodens 100-W B1KE-199

The Vitodens 100-W B1KE-199 is the largest combi in Viessmann Canada's 100-W series: 19.9 to 199 MBH heating input at 95% AFUE, with on-demand DHW at 4.7 USG/min continuous draw for homes with higher hot-water demand.

CurrentSold in Canada

Key figures

Max input
199 MBH
Max CSA output
AFUE
95 %
Min input
19.9 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitodens 100-W B1KE-199 in practice

The B1KE-199 combines the 199 MBH heating range with on-demand domestic hot water through a plate heat exchanger, making it the single-appliance answer for a larger home that wants combi simplicity. Its continuous DHW draw of 4.7 USG/min at a 77°F rise is about 40% higher than the B1KE-120's 3.3 USG/min, which covers busier bathroom use.

Heating input runs 19.9 to 199 MBH (5.8 to 58.3 kW) at 95% AFUE, and the boiler weighs 190 lb (86 kg) in the 17.75 x 21.75 x 39 inch cabinet shared with the B1HE-150 and B1HE-199 — so the wall, doorways and lifting plan are those of the larger 100-W models.

As with any combi, the sizing question is really about DHW: a house whose heat loss sits well below 199 MBH may still choose the B1KE-199 for its hot-water delivery, but the higher 19.9 MBH minimum fire should be weighed against a heating-only model with an indirect tank.

Best suited to

  • Larger homes wanting one wall-hung gas appliance for heat and hot water
  • Households whose simultaneous DHW demand exceeds the B1KE-120's 3.3 USG/min
  • Projects replacing both a boiler and a tank in the 100-W family footprint

Applicability and support

Model number
B1KE-199
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitodens 100-W B1KE-199 specifications
SpecificationValueNote
Input
Heating input, minimum (natural gas)19.9 MBH5.8 kW
Heating input, maximum (natural gas)199 MBH58.3 kW
Efficiency
Efficiency (AFUE)95 %95% AFUE on all models per the Canadian product page.
Domestic hot water
Continuous DHW draw at 77°F rise4.7 USG/minAt a 77°F (43K) rise, per the Canadian product page.
Domestic hot waterCombi: on-demand DHW via an integrated plate heat exchanger
Venting and air
Maximum vent run180 ftAs published; see the technical data manual for per-size and pipe-material limits.
Physical and connections
Weight190 lb86 kg
Width17.75 in450 mm
Depth21.75 in550 mm
Height39 in989 mm
Operating limits and other
FuelNatural gas or liquid propaneNo mechanical fuel-conversion adjustment required per the Canadian product page.
Turndown ratioup to 10:1Manufacturer claim; natural gas at high fire.

Frequently asked questions

How much more hot water does the B1KE-199 deliver than the B1KE-120?

Continuous DHW draw rises from 3.3 to 4.7 USG/min at a 77°F rise, per Viessmann Canada, and the heating input rises from 120 to 199 MBH.

How heavy is the B1KE-199?

190 lb (86 kg) per Viessmann Canada, versus 110 lb for the B1KE-120. It also stands 39 inches tall against 33.75 inches for the 120.

Is a 199 MBH combi too large for a typical home?

For heating alone, often yes — most homes do not need 199 MBH. But combis are sized for hot-water delivery as well: if the DHW demand exceeds the 120's 3.3 USG/min continuous draw, the 199 may be the correct combi despite the higher minimum fire.

Questions about the Viessmann Vitodens 100-W B1KE-199?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate