Viessmann · Vitodens 100-W (B1HE / B1KE)
Viessmann Vitodens 100-W B1HE-150
The Vitodens 100-W B1HE-150 is the 150 MBH heating-only model of Viessmann Canada's 100-W series: 15.5 to 150 MBH input at 95% AFUE, stepping up to a 179 lb, 39-inch-tall cabinet for larger detached homes.
Key figures
- Max input
- 150 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 15.5 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Viessmann Vitodens 100-W B1HE-150 in practice
The B1HE-150 fires from 15.5 to 150 MBH input (4.5 to 44.0 kW), which puts it in the range of larger detached homes and homes with a big indirect tank to recover. Along with the B1HE-199 it moves to the taller cabinet: 39 inches high and 21.75 inches deep at 179 lb (81 kg), so the mounting wall and lifting plan differ from the two smaller models.
It is heating-only — domestic hot water comes from an indirect tank — and it shares the MatriX-Plus cylinder burner, Inox-Radial stainless heat exchanger and 95% AFUE rating of the rest of the 100-W generation. The minimum fire rises to 15.5 MBH, so in a very low-load home the 120 or 85 would track mild weather more closely.
Viessmann Canada lists the series for natural gas or liquid propane with no mechanical conversion, zero clearance to combustibles and vent runs up to about 180 ft, so the 150 fits retrofit mechanical rooms where an old atmospheric boiler is coming out.
Best suited to
- Larger detached homes whose heat-loss calculation exceeds 120 MBH
- Homes with a high-recovery indirect tank and several heating zones
- Retrofits with up to about 180 ft of venting available
Applicability and support
- Model number
- B1HE-150
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum (natural gas) | 15.5 MBH | 4.5 kW |
| Input, maximum (natural gas) | 150 MBH | 44.0 kW |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95% AFUE on all models per the Canadian product page. |
| Domestic hot water | ||
| Domestic hot water | Not a combi; pair with an indirect tank | |
| Venting and air | ||
| Maximum vent run | 180 ft | As published; see the technical data manual for per-size and pipe-material limits. |
| Physical and connections | ||
| Weight | 179 lb | 81 kg |
| Width | 17.75 in | 450 mm |
| Depth | 21.75 in | 550 mm |
| Height | 39 in | 989 mm |
| Operating limits and other | ||
| Fuel | Natural gas or liquid propane | No mechanical fuel-conversion adjustment required per the Canadian product page. |
| Turndown ratio | up to 10:1 | Manufacturer claim; natural gas at high fire. |
Manuals
- Installation and Service Instructions — Vitodens 100-W B1HE and B1KE combi series, doc 6167 818 - 226167 818 - 22 · 2026-02
- Technical Data Manual — Vitodens 100-W B1HE/B1KE, doc 5472 801 - 095472 801 - 09 · 2026-02
Alerts documented for this model
- F.5
- F.7
- F.8
- F.13
- F.14
- F.49
- F.50
- F.59
- F.62
- F.63
- F.67
- F.68
- F.69
- F.70
- F.71
- F.72
- F.73
- F.74
- F.77
- F.89
- F.142
- F.160
- F.161
- F.163
- F.182
- F.183
- F.184
- F.185
- F.299
- F.342
- F.345
- F.346
- F.348
- F.349
- F.350
- F.351
- F.352
- F.353
- F.354
- F.355
- F.357
- F.359
- F.361
- F.366
- F.367
- F.369
- F.370
- F.372
- F.373
- F.377
- F.378
- F.379
- F.380
- F.381
- F.382
- F.383
- F.384
- F.385
- F.386
- F.387
- F.388
- F.395
- F.396
- F.399
- F.400
- F.401
- F.402
- F.403
- F.404
- F.405
- F.406
- F.408
- F.410
- F.416
- F.417
- F.418
- F.425
- F.430
- F.446
- F.447
- F.448
- F.449
- F.450
- F.451
- F.452
- F.453
- F.454
- F.455
- F.456
- F.457
- F.463
- F.464
- F.467
- F.468
- F.471
- F.473
- F.474
- F.527
- F.528
- F.540
Frequently asked questions
How heavy is the B1HE-150?
179 lb (81 kg) per Viessmann Canada, versus 108 lb for the 85 and 120 models. It is also taller (39 in vs 33.75 in) and deeper (21.75 in vs 19.75 in), which matters for the wall and the doorways on the way in.
When is 150 MBH the right size?
When the room-by-room heat-loss calculation plus the indirect-tank recovery load genuinely needs more than the 120 can deliver. If the load is lower, a smaller model with a lower minimum fire will condense more often.
Can the B1HE-150 be vented the same way as the smaller models?
The Canadian page quotes vent lengths up to about 180 ft for the series. Per-size and pipe-material limits are set out in the technical data manual, so the vent route should be checked against that document.
Questions about the Viessmann Vitodens 100-W B1HE-150?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Viessmann Vitodens 100-W B1HE-120 vs B1HE-150Comparison
- Viessmann Vitodens 100-W B1HE-150 vs B1HE-199Comparison
- IBC SL 20-160 G3 vs Viessmann Vitodens 100-W B1HE-150Comparison
- Viessmann Vitodens 100-W B1HE-85Same series
- Viessmann Vitodens 100-W B1HE-120Same series
- Viessmann Vitodens 100-W B1HE-199Same series
- Viessmann Vitodens 100-W B1KE-120Same series
- Viessmann Vitodens 100-W B1KE-199Same series
- Vitodens 100-W (B1HE / B1KE) series hub
- Buying guide
Sources and verification
- Viessmann Canada — Vitodens 100-W, B1HE/B1KE product page · accessed September 7, 2026
- Installation and Service Instructions — Vitodens 100-W B1HE/B1KE, doc 6167 818 - 22 · 6167 818 - 22 · accessed September 7, 2026
- Technical Data Manual — Vitodens 100-W B1HE/B1KE, doc 5472 801 - 09 · 5472 801 - 09 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.