Weil-McLain ECO Tec 110-H
The ECO Tec 110-H steps the heat-only line to 110 MBH input with 100 MBH DOE heating capacity at 95.0% AFUE, modulating 10:1 in the same 104 lb, 19 x 20 x 33 inch cabinet as the 80-H.
Key figures
- Max input
- 110 MBH
- Max CSA output
- 100 MBH
- AFUE
- 95 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Weil-McLain ECO Tec 110-H in practice
The 110-H fires to 110 MBH CSA input for 100 MBH of DOE heating capacity and an 87 MBH net AHRI rating, all at 95.0% AFUE. It shares the 80-H's cabinet and 2.2-gallon water content but steps to the full 10:1 modulation of the mid-size ECO Tec units, and it weighs the same 104 lb.
Venting matches the rest of the line: 2" or 3" PVC, CPVC, polypropylene or AL29-4C stainless steel to 100 equivalent feet from the 3" boiler connection, with an adapter available for 2" pipe. Heat-only operation means domestic hot water is produced by an indirect tank or a separate appliance.
Best suited to
- Homes whose heat-loss calculation sits around 80-110 MBH
- Buyers who want 10:1 modulation in the smallest ECO Tec cabinet
- Heat-only projects with an indirect tank for hot water
Applicability and support
- Model number
- ECO Tec 110-H
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, maximum | 110 MBH | CSA input (maximum). |
| Output | ||
| DOE heating capacity | 100 MBH | DOE heating capacity at maximum input; the manuals also call this CSA Output. |
| Net AHRI water rating | 87 MBH | Net AHRI rating per the boiler manual ratings table. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the boiler manual ratings table. |
| Venting and air | ||
| Venting | 2" or 3" PVC, CPVC, polypropylene or AL29-4C stainless steel (Category IV) | Canada: install per CAN/CSA B149.1 or B149.2 with a ULC S636-compliant vent kit. |
| Max. equivalent vent/air length | 100 ft in 2" or 3" (vent and air each) | |
| Physical and connections | ||
| Weight | 104 lb | Boiler weight per the Weil-McLain product spec table. |
| Dimensions (L x W x H) | 19" x 20" x 33" | |
| Gas connection | 1/2" NPT male | |
| Heating water connections | 1" NPT male | Relief valve/air vent connection is 3/4" NPT. |
| Operating limits and other | ||
| Turndown | 10:1 | 10:1 turndown per the CA page and brochure. |
| Boiler water content | 2.2 gal | |
| Altitude rating | 2,000 ft | No modifications from sea level to 2,000 ft; the boiler auto-derates about 4% per 1,000 ft above sea level. |
| Fuel | Natural gas or propane | Propane requires a conversion kit per the CA product page. |
Manuals
- ECO Tec Series 2 Boiler Manual, 550-100-270/0924550-100-270/0924 · 2024-09
Alerts documented for this model
- control-not-receiving-24v-power
- control-not-receiving-120v-power
- display-communication-lost
- TEMP RISE TOO QUICKLY
- Communication errors
- Control fault
- LOW WTR CUTOFF OPEN
- RETURN > SUPPLY
- Boiler Output sensor or Flue sensor
- FLUE TEMP TOO HIGH
- LIMIT OPEN
- HIGH TEMP LIMIT
- FALSE FLAME
- GAS RELAY FAULT 1-4
- IGNITION 1 FAULT
- IGNITION 2 FAULT
- FLAME LOSS FAULT
- AIR PRESSURE Switch Open
- Closure Switch fault
- Configuration fault
- DHW Outlet > Boiler Out
- Internal Clock Fault
- Supply 60F > Return
- Flue 1 Sensor Open
- Flue 1 Sensor Short
- Flue 2 Sensor Open
- Flue 2 Sensor Short
- Boiler Out 1 Sensor Open
- Boiler Out 1 Sensor Short
- Boiler Out 2 Sensor Open
- Boiler Out 2 Sensor Short
- Boiler In Sensor Open
- Boiler In Sensor Short
- Blower Fault 1
- Blower Fault 2
- Blower Fault 3
- Wrong J6 Jumper
- Hardware A2D Fault
- Flame Circuit Fault
- Supply Sensor
- Return Sensor
- DHW Outlet Sensor
- Outdoor Sensor Error
- Exceeded Flow Rate
- Target Reduced - Flue
- Target Reduced - Boiler
- Target Reduced - Flow
- Clock Fault
- Software Incompatible
- Virtual Input Active
- Unconfigured Net 1 or Net 2 Demand
Frequently asked questions
How is the 110-H different from the 80-H?
The 110-H adds 30 MBH of input ceiling (110 versus 80), gains 10:1 modulation instead of 8:1, and lifts DOE heating capacity from 74 to 100 MBH. Cabinet and weight are identical.
Is the ECO Tec 110-H a combi?
No. The 110-H is heating-only; the combi version is the ECO Tec 110-C with an integrated DHW module.
What net rating does the 110-H have?
The boiler manual lists an 87 MBH net AHRI water rating for the 110 at 95.0% AFUE.
Questions about the Weil-McLain ECO Tec 110-H?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Weil-McLain ECO Tec 80-H vs 110-HComparison
- Weil-McLain ECO Tec 110-H vs 150-HComparison
- NTI Trinity TRX120 vs Weil-McLain ECO Tec 110-HComparison
- Weil-McLain ECO Tec 80-HSame series
- Weil-McLain ECO Tec 150-HSame series
- Weil-McLain ECO Tec 199-HSame series
- Weil-McLain ECO Tec 110-CSame series
- Weil-McLain ECO Tec 150-CSame series
- Weil-McLain ECO Tec 199-CSame series
- ECO Tec series hub
- Buying guide
Sources and verification
- Weil-McLain Canada — ECO Tec (Heat Only) · accessed September 7, 2026
- ECO Tec Series 2 Boiler Manual 550-100-270/0924 · 550-100-270/0924 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.