Weil-McLain ECO Tec 150-H
The ECO Tec 150-H is the first ECO Tec size to grow the heat exchanger: 150 MBH input, 139 MBH DOE heating capacity and a 121 MBH net AHRI rating at 95.0% AFUE, in a 117 lb unit with 3.1 gallons of water content.
Key figures
- Max input
- 150 MBH
- Max CSA output
- 139 MBH
- AFUE
- 95 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Weil-McLain ECO Tec 150-H in practice
The 150-H fires to 150 MBH CSA input for 139 MBH of DOE heating capacity and a 121 MBH net AHRI rating at 95.0% AFUE, with the 10:1 modulation shared by the 110-199 sizes. Its 3.1-gallon water content and 117 lb weight sit between the 110 and the 199 in the ECO Tec line.
It is a Category IV direct-vent boiler in the shared 19 x 20 x 33 inch cabinet, vented in 2" or 3" PVC, CPVC, polypropylene or AL29-4C stainless steel to 100 equivalent feet. Heat-only duty means domestic hot water is handled by an indirect tank or separate appliance.
Best suited to
- Homes with heat-loss calculations in the 110-150 MBH band
- Systems with baseboard or radiator emitters sized near 140 MBH of output
- Buyers who want mid-range ECO Tec capacity without the 199's 2" vent limit
Applicability and support
- Model number
- ECO Tec 150-H
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, maximum | 150 MBH | CSA input (maximum). |
| Output | ||
| DOE heating capacity | 139 MBH | DOE heating capacity at maximum input; the manuals also call this CSA Output. |
| Net AHRI water rating | 121 MBH | Net AHRI rating per the boiler manual ratings table. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the boiler manual ratings table. |
| Venting and air | ||
| Venting | 2" or 3" PVC, CPVC, polypropylene or AL29-4C stainless steel (Category IV) | Canada: install per CAN/CSA B149.1 or B149.2 with a ULC S636-compliant vent kit. |
| Max. equivalent vent/air length | 100 ft in 2" or 3" (vent and air each) | |
| Physical and connections | ||
| Weight | 117 lb | Boiler weight per the Weil-McLain product spec table. |
| Dimensions (L x W x H) | 19" x 20" x 33" | |
| Gas connection | 1/2" NPT male | |
| Heating water connections | 1" NPT male | Relief valve/air vent connection is 3/4" NPT. |
| Operating limits and other | ||
| Turndown | 10:1 | 10:1 turndown per the CA page and brochure. |
| Boiler water content | 3.1 gal | |
| Altitude rating | 2,000 ft | No modifications from sea level to 2,000 ft; the boiler auto-derates about 4% per 1,000 ft above sea level. |
| Fuel | Natural gas or propane | Propane requires a conversion kit per the CA product page. |
Manuals
- ECO Tec Series 2 Boiler Manual, 550-100-270/0924550-100-270/0924 · 2024-09
Alerts documented for this model
- control-not-receiving-24v-power
- control-not-receiving-120v-power
- display-communication-lost
- TEMP RISE TOO QUICKLY
- Communication errors
- Control fault
- LOW WTR CUTOFF OPEN
- RETURN > SUPPLY
- Boiler Output sensor or Flue sensor
- FLUE TEMP TOO HIGH
- LIMIT OPEN
- HIGH TEMP LIMIT
- FALSE FLAME
- GAS RELAY FAULT 1-4
- IGNITION 1 FAULT
- IGNITION 2 FAULT
- FLAME LOSS FAULT
- AIR PRESSURE Switch Open
- Closure Switch fault
- Configuration fault
- DHW Outlet > Boiler Out
- Internal Clock Fault
- Supply 60F > Return
- Flue 1 Sensor Open
- Flue 1 Sensor Short
- Flue 2 Sensor Open
- Flue 2 Sensor Short
- Boiler Out 1 Sensor Open
- Boiler Out 1 Sensor Short
- Boiler Out 2 Sensor Open
- Boiler Out 2 Sensor Short
- Boiler In Sensor Open
- Boiler In Sensor Short
- Blower Fault 1
- Blower Fault 2
- Blower Fault 3
- Wrong J6 Jumper
- Hardware A2D Fault
- Flame Circuit Fault
- Supply Sensor
- Return Sensor
- DHW Outlet Sensor
- Outdoor Sensor Error
- Exceeded Flow Rate
- Target Reduced - Flue
- Target Reduced - Boiler
- Target Reduced - Flow
- Clock Fault
- Software Incompatible
- Virtual Input Active
- Unconfigured Net 1 or Net 2 Demand
Frequently asked questions
What does the 150-H deliver over the 110-H?
The 150-H raises input from 110 to 150 MBH, DOE heating capacity from 100 to 139 MBH, and the net AHRI rating from 87 to 121 MBH; water content grows from 2.2 to 3.1 gallons and weight from 104 to 117 lb.
Is the 150-H a combi boiler?
No, it is heating-only. The combi version is the ECO Tec 150-C.
Can the 150-H use 2" venting?
Yes — 2" or 3" venting is allowed to 100 equivalent feet for the 150 size, unlike the 199 which drops to 50 feet in 2" pipe.
Questions about the Weil-McLain ECO Tec 150-H?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Weil-McLain ECO Tec 110-H vs 150-HComparison
- Weil-McLain ECO Tec 150-H vs 199-HComparison
- Weil-McLain ECO Tec 150-H vs 150-CComparison
- NTI Trinity TFTN150 vs Weil-McLain ECO Tec 150-HComparison
- Weil-McLain ECO Tec 150-H vs Lochinvar Knight WHB155Comparison
- Burnham Alpine ALP150B vs Weil-McLain ECO Tec 150-HComparison
- Weil-McLain ECO Tec 80-HSame series
- Weil-McLain ECO Tec 110-HSame series
- Weil-McLain ECO Tec 199-HSame series
- Weil-McLain ECO Tec 110-CSame series
- Weil-McLain ECO Tec 150-CSame series
- Weil-McLain ECO Tec 199-CSame series
- ECO Tec series hub
- Buying guide
Sources and verification
- Weil-McLain Canada — ECO Tec (Heat Only) · accessed September 7, 2026
- ECO Tec Series 2 Boiler Manual 550-100-270/0924 · 550-100-270/0924 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.