Weil-McLain ECO Tec AIR PRESSURE Switch Open — Air Pressure Switch Connection is Open
AIR PRESSURE Switch Open
Air pressure switch connection is open. This fault occurs when the air pressure switch connection is open, and it must be reset using the Manual Reset screen on the display. The table classifies it as Reset using Manual Reset screen on display..
Applies to
This venting or air-supply fault code is displayed by the ECO Tec control (display messages) on ECO Tec Series 2 models (80–199 heating-only and 110–199 combi), as documented in ECO Tec Series 2 Boiler Manual, doc 550-100-270/0924 (550-100-270/0924). Codes can differ between controller generations, so always check the manual that matches your unit.
- Weil-McLain ECO Tec
- Weil-McLain ECO Tec 80-H
- Weil-McLain ECO Tec 110-H
- Weil-McLain ECO Tec 150-H
- Weil-McLain ECO Tec 199-H
- Weil-McLain ECO Tec 110-C
- Weil-McLain ECO Tec 150-C
- Weil-McLain ECO Tec 199-C
Controller: ECO Tec control (display messages). Source manual: 550-100-270/0924 (2024-09).
Why a code is not a diagnosis
A venting or air-supply code points at the combustion-air path: a blocked terminal, a restricted flue, a failed fan, or a condensate restriction. It does not say which, and running an appliance with a blocked flue is unsafe.
Safe things to observe
- If a carbon-monoxide alarm sounds anywhere in the building, leave immediately and call 911 from outside.
- From a safe distance, check that the vent terminal and combustion-air inlet are not blocked.
- Do not run the appliance while a blockage is suspected.
Do not
- Do not put anything into the vent or air-intake openings.
- Do not remove or modify vent pipe.
How professional service helps
- A technician inspects the full vent and combustion-air path, clears blockages and checks the fan.
- Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Air pressure switch
An air pressure switch proves that the combustion fan is moving air and that the vent path is clear before the boiler is allowed to fire.
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for Weil-McLain ECO Tec.
Frequently asked questions
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- ECO Tec Series 2 Boiler Manual, doc 550-100-270/0924 · 550-100-270/0924 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.