Weil-McLain ECO Tec 199-H
The ECO Tec 199-H tops the heat-only line at 199 MBH input with 184 MBH DOE heating capacity and a 160 MBH net AHRI rating at 95.0% AFUE, weighing 127 lb with 3.8 gallons of water content.
Key figures
- Max input
- 199 MBH
- Max CSA output
- 184 MBH
- AFUE
- 95 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Weil-McLain ECO Tec 199-H in practice
The 199-H is the largest ECO Tec heat-only size: 199 MBH CSA input, 184 MBH DOE heating capacity and a 160 MBH net AHRI rating at 95.0% AFUE with 10:1 modulation. It holds 3.8 gallons of boiler water and weighs 127 lb, and its 2" venting is the one ECO Tec restriction — the manual allows only 50 equivalent feet in 2" for the 199, against 100 feet for every other size.
Installation is otherwise shared with the line: Category IV direct vent in 2" or 3" PVC, CPVC, polypropylene or AL29-4C stainless steel, 1" NPT heating connections, 1/2" NPT gas, and no altitude modifications to 2,000 ft. It is heating-only, so hot water comes from an indirect tank or separate appliance.
Best suited to
- Larger homes and small multi-suite buildings above 150 MBH of load
- Systems that can run 3" venting and avoid the 199's 50-ft 2" limit
- Heat-only projects needing the ECO Tec line's top capacity
Applicability and support
- Model number
- ECO Tec 199-H
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, maximum | 199 MBH | CSA input (maximum). |
| Output | ||
| DOE heating capacity | 184 MBH | DOE heating capacity at maximum input; the manuals also call this CSA Output. |
| Net AHRI water rating | 160 MBH | Net AHRI rating per the boiler manual ratings table. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the boiler manual ratings table. |
| Venting and air | ||
| Venting | 2" or 3" PVC, CPVC, polypropylene or AL29-4C stainless steel (Category IV) | Canada: install per CAN/CSA B149.1 or B149.2 with a ULC S636-compliant vent kit. |
| Max. equivalent vent/air length | 100 ft in 2" or 3" — 50 ft maximum in 2" for the 199 size | |
| Physical and connections | ||
| Weight | 127 lb | Boiler weight per the Weil-McLain product spec table. |
| Dimensions (L x W x H) | 19" x 20" x 33" | |
| Gas connection | 1/2" NPT male | |
| Heating water connections | 1" NPT male | Relief valve/air vent connection is 3/4" NPT. |
| Operating limits and other | ||
| Turndown | 10:1 | 10:1 turndown per the CA page and brochure. |
| Boiler water content | 3.8 gal | |
| Altitude rating | 2,000 ft | No modifications from sea level to 2,000 ft; the boiler auto-derates about 4% per 1,000 ft above sea level. |
| Fuel | Natural gas or propane | Propane requires a conversion kit per the CA product page. |
Manuals
- ECO Tec Series 2 Boiler Manual, 550-100-270/0924550-100-270/0924 · 2024-09
Alerts documented for this model
- control-not-receiving-24v-power
- control-not-receiving-120v-power
- display-communication-lost
- TEMP RISE TOO QUICKLY
- Communication errors
- Control fault
- LOW WTR CUTOFF OPEN
- RETURN > SUPPLY
- Boiler Output sensor or Flue sensor
- FLUE TEMP TOO HIGH
- LIMIT OPEN
- HIGH TEMP LIMIT
- FALSE FLAME
- GAS RELAY FAULT 1-4
- IGNITION 1 FAULT
- IGNITION 2 FAULT
- FLAME LOSS FAULT
- AIR PRESSURE Switch Open
- Closure Switch fault
- Configuration fault
- DHW Outlet > Boiler Out
- Internal Clock Fault
- Supply 60F > Return
- Flue 1 Sensor Open
- Flue 1 Sensor Short
- Flue 2 Sensor Open
- Flue 2 Sensor Short
- Boiler Out 1 Sensor Open
- Boiler Out 1 Sensor Short
- Boiler Out 2 Sensor Open
- Boiler Out 2 Sensor Short
- Boiler In Sensor Open
- Boiler In Sensor Short
- Blower Fault 1
- Blower Fault 2
- Blower Fault 3
- Wrong J6 Jumper
- Hardware A2D Fault
- Flame Circuit Fault
- Supply Sensor
- Return Sensor
- DHW Outlet Sensor
- Outdoor Sensor Error
- Exceeded Flow Rate
- Target Reduced - Flue
- Target Reduced - Boiler
- Target Reduced - Flow
- Clock Fault
- Software Incompatible
- Virtual Input Active
- Unconfigured Net 1 or Net 2 Demand
Frequently asked questions
Can the ECO Tec 199-H vent in 2" pipe?
Yes, but only to 50 equivalent feet — the manual limits the 199 size to 50 ft in 2" while other sizes reach 100 ft. In 3" pipe the 199 is allowed the full 100 ft.
What rating does the 199-H carry?
199 MBH input, 184 MBH DOE heating capacity, 160 MBH net AHRI and 95.0% AFUE per the boiler manual.
Is there an ECO Tec 199 combi?
Yes — the ECO Tec 199-C adds the integrated DHW module to the same 199 MBH platform.
Questions about the Weil-McLain ECO Tec 199-H?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
Sources and verification
- Weil-McLain Canada — ECO Tec (Heat Only) · accessed September 7, 2026
- ECO Tec Series 2 Boiler Manual 550-100-270/0924 · 550-100-270/0924 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.