Weil-McLain ECO Tec 110-C
The ECO Tec 110-C is the entry combi of the Canadian ECO Tec line: the 110 MBH heat-only platform plus an integrated brazed plate DHW module for on-demand hot water, rated 95.0% AFUE at 114 lb.
Key figures
- Max input
- 110 MBH
- Max CSA output
- 100 MBH
- AFUE
- 95 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Weil-McLain ECO Tec 110-C in practice
The 110-C is the smallest ECO Tec with a domestic hot water module: it carries the same heating ratings as the 110-H — 110 MBH input, 100 MBH DOE heating capacity, 87 MBH net AHRI at 95.0% AFUE — and adds the brazed plate DHW section that produces hot water on demand, so no separate tank is required for the hot water side.
The CA product page markets the ECO Tec combi range at up to 5.4 GPM of DHW at a 70°F rise, a claim Weil-McLain's brochure ties to the 199 size; the combi models fire to the same 110 MBH ceiling on both heating and DHW duty. At 114 lb the 110-C is 10 lb heavier than the 110-H, in the same 19 x 20 x 33 inch cabinet with 2" or 3" venting to 100 ft.
Best suited to
- Homes that want one gas appliance for heat and hot water
- Heat-loss loads up to about 110 MBH with modest hot-water demand
- Replacing a boiler plus tank with a single condensing combi
Applicability and support
- Model number
- ECO Tec 110-C
- Canadian availability
- available
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, maximum | 110 MBH | CSA input (maximum). |
| Output | ||
| DOE heating capacity | 100 MBH | DOE heating capacity at maximum input; the manuals also call this CSA Output. |
| Net AHRI water rating | 87 MBH | Net AHRI rating per the boiler manual ratings table. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the boiler manual ratings table. |
| Domestic hot water | ||
| Domestic hot water | Integrated combi: built-in DHW module with brazed plate heat exchanger | |
| Venting and air | ||
| Venting | 2" or 3" PVC, CPVC, polypropylene or AL29-4C stainless steel (Category IV) | Canada: install per CAN/CSA B149.1 or B149.2 with a ULC S636-compliant vent kit. |
| Max. equivalent vent/air length | 100 ft in 2" or 3" (vent and air each) | |
| Physical and connections | ||
| Weight | 114 lb | Boiler weight per the Weil-McLain product spec table. |
| Dimensions (L x W x H) | 19" x 20" x 33" | |
| Gas connection | 1/2" NPT male | |
| Heating water connections | 1" NPT male | Relief valve/air vent connection is 3/4" NPT. |
| Operating limits and other | ||
| Turndown | 10:1 | 10:1 turndown per the CA page and brochure. |
| Boiler water content | 2.2 gal | |
| Altitude rating | 2,000 ft | No modifications from sea level to 2,000 ft; the boiler auto-derates about 4% per 1,000 ft above sea level. |
| Fuel | Natural gas or propane | Propane requires a conversion kit per the CA product page. |
Manuals
- ECO Tec Series 2 Boiler Manual, 550-100-270/0924550-100-270/0924 · 2024-09
Alerts documented for this model
- control-not-receiving-24v-power
- control-not-receiving-120v-power
- display-communication-lost
- TEMP RISE TOO QUICKLY
- Communication errors
- Control fault
- LOW WTR CUTOFF OPEN
- RETURN > SUPPLY
- Boiler Output sensor or Flue sensor
- FLUE TEMP TOO HIGH
- LIMIT OPEN
- HIGH TEMP LIMIT
- FALSE FLAME
- GAS RELAY FAULT 1-4
- IGNITION 1 FAULT
- IGNITION 2 FAULT
- FLAME LOSS FAULT
- AIR PRESSURE Switch Open
- Closure Switch fault
- Configuration fault
- DHW Outlet > Boiler Out
- Internal Clock Fault
- Supply 60F > Return
- Flue 1 Sensor Open
- Flue 1 Sensor Short
- Flue 2 Sensor Open
- Flue 2 Sensor Short
- Boiler Out 1 Sensor Open
- Boiler Out 1 Sensor Short
- Boiler Out 2 Sensor Open
- Boiler Out 2 Sensor Short
- Boiler In Sensor Open
- Boiler In Sensor Short
- Blower Fault 1
- Blower Fault 2
- Blower Fault 3
- Wrong J6 Jumper
- Hardware A2D Fault
- Flame Circuit Fault
- Supply Sensor
- Return Sensor
- DHW Outlet Sensor
- Outdoor Sensor Error
- Exceeded Flow Rate
- Target Reduced - Flue
- Target Reduced - Boiler
- Target Reduced - Flow
- Clock Fault
- Software Incompatible
- Virtual Input Active
- Unconfigured Net 1 or Net 2 Demand
Frequently asked questions
What does the C stand for in ECO Tec 110-C?
The C marks the combi variant: the heat-only 110-H ratings with an added DHW module for on-demand domestic hot water.
How much hot water does the 110-C deliver?
Weil-McLain publishes DHW delivery for the ECO Tec combi range as up to 5.4 GPM at a 70°F rise on the largest (199) size; the exact flow of the 110-C depends on the DHW temperature rise.
Is the 110-C heavier than the 110-H?
Yes — 114 lb against 104 lb for the heat-only 110-H, per the Weil-McLain spec table.
Questions about the Weil-McLain ECO Tec 110-C?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
Sources and verification
- Weil-McLain Canada — ECO Tec (Combi) · accessed September 7, 2026
- ECO Tec Series 2 Boiler Manual 550-100-270/0924 · 550-100-270/0924 · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.