Weil-McLain EG-40

The EG-40 raises the EG line to 125 MBH input with 106/103 MBH water/steam DOE heating capacity, 321 sq ft of steam coverage and 84%/82% AFUE; discontinued in Canada, still sold in the US as EG Series 6 and Series 7.

DiscontinuedHistorically in Canada

Key figures

Max input
125 MBH
Max CSA output
AFUE
Min input
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Weil-McLain EG-40 in practice

The EG-40 is rated 125 MBH CSA input and produces 106 MBH of DOE water heating capacity and 103 MBH in steam, with net AHRI ratings of 92 MBH water and 77 MBH steam covering 321 sq ft. It keeps the range's 84% water / 82% steam AFUE and ships at approximately 505 lb.

It uses the same atmospheric cast iron construction with Category I, B-vent vertical venting, a draft hood, an automatic vent damper and a 6" I.D. chimney collar. The connections are a 3" supply, 2-1/2" return, 1/2" gas and 3/4" relief, with 14.8 gal of water content and 9.8 gal to the steam waterline. The EG is discontinued in Canada; US sales continue as Series 6 and Series 7.

Best suited to

  • Mid-size water or steam loads near 125 MBH
  • Buildings with a 6" chimney and atmospheric venting
  • Comparing EG generations across the Canadian/US split

Applicability and support

Model number
EG-40
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Weil-McLain. Units are shown with every value; notes flag conflicting sources or missing figures.

Weil-McLain EG-40 specifications
SpecificationValueNote
Input
Input, maximum125 MBHCSA input per the US EG Series 6/7 spec tables and the EG Series 7 manual ratings table (Table 20).
Output
DOE heating capacity, water106 MBHWater heating capacity per manual Table 20; matches the CA discontinued page's output figure.
DOE heating capacity, steam103 MBHSteam heating capacity per manual Table 20.
Net AHRI rating, water92 MBHNet AHRI water rating based on a 1.15 piping and pick-up allowance per the manual ratings notes.
Net AHRI rating, steam77 MBHNet AHRI steam rating based on a 1.333 pick-up allowance per the manual ratings notes.
Net AHRI steam rating, area321 sq ftSteam square-foot rating per manual Table 20; the CA discontinued page's published range ends at 750 sq ft, which does not match the EG-75's 733 sq ft.
Efficiency
AFUE, water84 %84.0% AFUE in water per manual Table 21 and the US spec tables.
AFUE, steam82 %82.0% AFUE in steam per manual Table 21 and the US spec tables.
Venting and air
VentingCategory I, B-vent — vertical vent only, natural draft with draft hood and automatic vent damper; 6" I.D. chimney x 20 ftPer the US spec tables (chimney size) and the CA discontinued page (Cat. 1, B-vent, vertical vent only).
Physical and connections
Supply connection3"Supply tapping O is 1 x 3" on every EG/PEG size per the Series 7 manual connections section.
Return connection2-1/2"Return tapping P is 1 x 2-1/2" on every EG/PEG size per the Series 7 manual connections section.
Gas connection1/2"Gas connection F is 1/2" on EG/PEG-30 through -55 per the Series 7 manual.
Relief valve3/4" tappingWater boilers use a 3/4" tapping on the side with a 30 psi relief valve; steam boilers use a 15 psi relief valve on a top tapping per the Series 7 manual.
Weight505 lbApproximate shipping weight per the US spec tables and manual Table 20.
Operating limits and other
Boiler water content14.8 galWater content per manual Table 20.
Steam-to-waterline content9.8 galSteam-to-waterline water content per manual Table 20.

Frequently asked questions

What are the EG-40's ratings?

125 MBH CSA input, 106 MBH DOE water heating capacity, 103 MBH steam, 92 MBH net AHRI water, 77 MBH net AHRI steam (321 sq ft), and 84% water / 82% steam AFUE per the US spec tables and manual.

What are the EG-40's connections?

A 3" supply tapping, 2-1/2" return, 1/2" gas connection and 3/4" relief tapping, per the EG Series 7 manual connections section.

Is the EG-40 available in Canada?

No. The EG / EG Steam page on weil-mclain.ca is in the Discontinued menu; the US still sells the EG-40 as part of EG Series 6 and Series 7.

Questions about the Weil-McLain EG-40?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate