Lochinvar Noble Air Pressure Switch — Air Pressure Switch Contacts are Open
Air Pressure Switch
Air pressure switch contacts are open. The air pressure switch contacts are open, so check the switch wiring to the common and normally closed terminals, air intake lengths and obstructions, the reference hoses, the burner, and the heat exchanger, and replace a faulty air pressure switch. The table classifies it as Lockout (manual reset).
Applies to
This venting or air-supply fault code is displayed by the SMART CONTROL on Noble fire-tube models (NKB080–199 boilers, NKC110–199 and NCF110–199 combis), as documented in Noble Installation & Service Manual, doc 100275091 Rev AN — fault tables (100275091 Rev AN). Codes can differ between controller generations, so always check the manual that matches your unit.
- Lochinvar Noble Fire Tube (NKB/NKC/NCF)
- Lochinvar Noble NKB080
- Lochinvar Noble NKB110
- Lochinvar Noble NKB150
- Lochinvar Noble NKB199
- Lochinvar Noble NKC110
- Lochinvar Noble NKC150
- Lochinvar Noble NKC199
- Lochinvar Noble NCF110
- Lochinvar Noble NCF150
- Lochinvar Noble NCF199
Controller: SMART CONTROL. Source manual: 100275091 Rev AN.
Why a code is not a diagnosis
A venting or air-supply code points at the combustion-air path: a blocked terminal, a restricted flue, a failed fan, or a condensate restriction. It does not say which, and running an appliance with a blocked flue is unsafe.
Safe things to observe
- If a carbon-monoxide alarm sounds anywhere in the building, leave immediately and call 911 from outside.
- From a safe distance, check that the vent terminal and combustion-air inlet are not blocked.
- Do not run the appliance while a blockage is suspected.
Do not
- Do not put anything into the vent or air-intake openings.
- Do not remove or modify vent pipe.
How professional service helps
- A technician inspects the full vent and combustion-air path, clears blockages and checks the fan.
- Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Parts and service
Parts commonly involved
These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.
Heat exchanger
The heat exchanger is where a boiler transfers heat from the burner flame to the water that heats your home.
What a technician checks →Air pressure switch
An air pressure switch proves that the combustion fan is moving air and that the vent path is clear before the boiler is allowed to fire.
What a technician checks →Burner assembly
The burner assembly is where gas and air meet and burn inside a boiler, and its condition decides whether combustion is clean or makes carbon…
What a technician checks →Boiler venting (flue and air intake)
A condensing boiler vents cool, wet flue gases through dedicated plastic pipe that must meet ULC S636 in Canada and the boiler manufacturer's own…
What a technician checks →
Service for this alert
- Gas Boiler Repair
Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…
- Emergency Boiler Repair
Priority gas boiler repair for homes and buildings in Greater Vancouver with no heat, no hot water, a locked-out boiler or a leak.
- Gas Boiler Replacement
ROMA replaces old, failed or inefficient gas boilers in Greater Vancouver, handling removal, venting and gas-supply changes,…
Every boiler part explained — what it does, how it fails and what a technician checks.
Documented for Lochinvar Noble Fire Tube (NKB/NKC/NCF).
Frequently asked questions
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Noble Installation & Service Manual, doc 100275091 Rev AN — fault tables · 100275091 Rev AN · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.