Skip to content
Boilers.caby ROMA Heating & Cooling

Triangle Tube · Instinct

Triangle Tube Instinct 155C (floor combi)

The Instinct 155C floor combi (INSFS155C) delivers the wall combi's 19.375 to 155 MBH and 4.0 GPM DHW performance in a floor-standing 181 lb cabinet. Discontinued with the November 3, 2025 cessation.

DiscontinuedHistorically in Canada

Key figures

Max input
155 MBH
Max CSA output
AFUE
95 %
Min input
19.375 MBH
Natural gasPropaneCombiresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Triangle Tube Instinct 155C (floor combi) in practice

The INSFS155C is the floor version of the 155C combi: the same 19,375 to 155,000 BTU/h input at 95% AFUE with an 8:1 turndown, 142 MBH DOE capacity and 123 MBH net AHRI, plus the plate heat exchanger whose DHW performance the product page describes as identical to the wall combi — 4.0 GPM at a 70°F rise.

The floor form factor changes the numbers that matter on site: 181 lb, a 22" x 41" x 22" cabinet, 1" MNPT supply/return connections (1 1/4" FPT with the 548 Caleffi Separator), a 3/4" MNPT gas connection and 3" venting to 100 ft. The DHW side keeps the 150 °F maximum flow temperature, 0.5 GPM minimum flow and 150 psi maximum operating pressure of the combi line. Triangle Tube ceased operations November 3, 2025; this model is documented for the installed base.

Best suited to

  • Basement installs that want combi hot water without a wall-mounted unit
  • Floor-standing plants needing the 155-class heating range and 4.0 GPM DHW at 70°F
  • Mechanical rooms where the 22-inch cabinet footprint fits the floor plan

Applicability and support

Model number
INSFS155C
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Triangle Tube. Units are shown with every value; notes flag conflicting sources or missing figures.

Triangle Tube Instinct 155C (floor combi) specifications
SpecificationValueNote
Input
Heating input, minimum19.375 MBH19,375 to 155,000 BTU/h as printed.
Heating input, maximum155 MBH19,375 to 155,000 BTU/h as printed.
Output
DOE heating capacity142 MBHPer the product-page spec table.
Net AHRI rating123 MBHPer the product-page spec table.
Efficiency
Efficiency (AFUE)95 %95% AFUE per the product-page spec table.
Domestic hot water
Maximum DHW flow temperature150 °F (65 °C)Per the product page.
DHW output at 70°F rise4 GPMPerformance identical to the wall combi per the product page.
DHW minimum flow0.5 GPM
DHW maximum operating pressure150 psi
Venting and air
Vent/air diameter3" connection; 3-in-1 adapter accepts PVC, polypropylene or stainless steelPer the product-page spec table.
Maximum vent length, 3"100 ftPer the product page and vent supplement 241576.
Physical and connections
Weight181 lb
Width22 in
Height41 in
Depth22 in
Supply/return connections1" MNPT1 1/4" FPT when using the 548 Caleffi Separator, per the product-page footnote.
Gas connection3/4" MNPT
Operating limits and other
FuelNatural gas or propane
Turndown ratio8:1
Maximum CH flow temperature185 °FPer the product page.

Frequently asked questions

Is the floor 155C's hot water output the same as the wall 155C?

The product page states the floor combi's performance is identical to the wall combi's, which publishes 4.0 GPM of DHW at a 70°F rise. What differs is the package: 181 lb in a 22 x 41 x 22-inch floor cabinet.

Which manual covers the INSFS155C?

The floor-series installation manual 242194 (Rev. A02, September 2025) covers the floor solos and combis, including the INSFS155C; the wall manual 241573 covers the wall-hung INS models.

Questions about the Triangle Tube Instinct 155C (floor combi)?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate