Triangle Tube Instinct 155C (wall combi)
The Instinct 155C (INS155C) is the wall-hung Instinct combi at 155-class size: 19.375 to 155 MBH heating input plus a large plate heat exchanger delivering 4.0 GPM of DHW at a 70°F rise, rated 95% AFUE. Discontinued with the November 3, 2025 cessation.
Key figures
- Max input
- 155 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 19.375 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Triangle Tube Instinct 155C (wall combi) in practice
The 155C is the smaller of the two Instinct wall combis: the same 19,375 to 155,000 BTU/h firing range as the 155S solo, at 95% AFUE with an 8:1 turndown, plus a large plate heat exchanger that produces domestic hot water on demand — the product page markets 5+ GPM of hot water while fully condensing in DHW mode across the combi line. Published DHW delivery on the 155C is 4.0 GPM at a 70°F rise (3.7 GPM at 75°F, 3.5 GPM at 80°F).
Compared with the 155S solo, the combi cabinet grows 7" taller (33" against 26") and heavier at 110 lb, and its page prints no 2" vent run — 3" venting to 100 ft is the listed allowance. The DHW side is rated for a 150 °F maximum flow temperature, a 0.5 GPM minimum flow and 150 psi maximum operating pressure. Triangle Tube ceased operations November 3, 2025; this model is documented for the installed base.
Best suited to
- Homes that want a single wall-hung appliance for heating and on-demand hot water
- Projects sized near 155 MBH where the combi's 4.0 GPM DHW delivery at 70°F fits the draw pattern
- Retrofits replacing a boiler plus tank in the same wall footprint
Applicability and support
- Model number
- INS155C
- Canadian availability
- historical
- Production status
- discontinued
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Series terms
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Triangle Tube. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Heating input, minimum | 19.375 MBH | 19,375 to 155,000 BTU/h as printed. |
| Heating input, maximum | 155 MBH | 19,375 to 155,000 BTU/h as printed. |
| Output | ||
| DOE heating capacity | 142 MBH | Per the product-page spec table. |
| Net AHRI rating | 123 MBH | Per the product-page spec table. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95% AFUE per the product-page spec table. |
| Domestic hot water | ||
| Maximum DHW flow temperature | 150 °F (65 °C) | Per the product page. |
| DHW output at 70°F rise | 4 GPM | Per the product page. |
| DHW output at 75°F rise | 3.7 GPM | Per the product page. |
| DHW output at 80°F rise | 3.5 GPM | Per the product page. |
| DHW minimum flow | 0.5 GPM | |
| DHW maximum operating pressure | 150 psi | |
| Venting and air | ||
| Maximum vent length, 3" | 100 ft | Per the product page and vent supplement 241576; the combi page prints no 2" run. |
| Vent/air diameter | 3" connection; 3-in-1 adapter accepts PVC, polypropylene or stainless steel | Per the product-page spec table. |
| Physical and connections | ||
| Water volume | 3 gal | |
| Weight | 110 lb | |
| Width | 21.75 in | The combi cabinet is 7" taller than the wall solo. |
| Height | 33 in | |
| Depth | 16.5 in | |
| Supply/return connections | 1" MNPT | |
| Gas connection | 3/4" MNPT | |
| Operating limits and other | ||
| Fuel | Natural gas or propane | |
| Turndown ratio | 8:1 | |
| Maximum CH flow temperature | 185 °F | Per the product page. |
Manuals
- Instinct Wall (WHB) Installation & Maintenance Manual — Solo 110-155-199 & Combi 155-199241573 Rev. A03 · 2025-09
Alerts documented for this model
Frequently asked questions
How much hot water can the Instinct 155C deliver?
The product page publishes 4.0 GPM of DHW output at a 70°F temperature rise, 3.7 GPM at 75°F and 3.5 GPM at 80°F, with a 0.5 GPM minimum flow and 150 psi maximum operating pressure on the DHW side.
What is the difference between the 155C and the 155S?
Both fire 19,375 to 155,000 BTU/h at 95% AFUE, but the 155C adds the plate heat exchanger and DHW module for on-demand hot water, stands 7" taller (33" versus 26"), and weighs 110 lb against 95 lb.
Questions about the Triangle Tube Instinct 155C (wall combi)?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Triangle Tube Instinct 110S (wall)Same series
- Triangle Tube Instinct 155S (wall)Same series
- Triangle Tube Instinct 199S (wall)Same series
- Triangle Tube Instinct 110S (floor)Same series
- Triangle Tube Instinct 155S (floor)Same series
- Triangle Tube Instinct 199S (floor)Same series
- Triangle Tube Instinct 199C (wall combi)Same series
- Triangle Tube Instinct 155C (floor combi)Same series
- Triangle Tube Instinct 199C (floor combi)Same series
- Instinct series hub
- Buying guide
Sources and verification
- Instinct Wall Installation & Maintenance Manual, 241573 Rev. A03 (09/2025) · accessed September 7, 2026
- Instinct Wall & Floor Vent Supplement, 241576 Rev. A02 (09/2025) · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.