Triangle Tube Instinct 199C (wall combi)

The Instinct 199C (INS199C) is the top Instinct wall combi: 24.875 to 199 MBH heating input with 5.3 GPM of DHW at a 70°F rise, rated 95% AFUE in a 130 lb wall cabinet. Discontinued with the November 3, 2025 cessation.

DiscontinuedHistorically in Canada

Key figures

Max input
199 MBH
Max CSA output
AFUE
95 %
Min input
24.875 MBH
Natural gasPropaneCombiresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Triangle Tube Instinct 199C (wall combi) in practice

The 199C pairs the largest Instinct wall firing range — 24,875 to 199,000 BTU/h at 95% AFUE with an 8:1 turndown — with the combi's large plate heat exchanger, which the product page says keeps the boiler fully condensing in DHW mode. Its published DHW delivery of 5.3 GPM at a 70°F rise is the figure behind the line's '5+ GPM of hot water' claim, and it reaches 4.9 GPM at 75°F and 4.6 GPM at 80°F.

At 130 lb and 21.75" wide by 33" tall it is the heaviest wall-hung Instinct, holding 4 gallons of water with 1" MNPT supply/return connections and a 3/4" MNPT gas connection. The DHW side is rated for a 150 °F maximum flow temperature with a 0.5 GPM minimum flow and 150 psi maximum operating pressure, and venting is 3" to 100 ft with no 2" run listed. Triangle Tube ceased operations November 3, 2025; this model is documented for the installed base.

Best suited to

  • Larger homes wanting one wall-hung combi with 199 MBH of heating headroom
  • Households whose hot-water draws benefit from the 5.3 GPM DHW rating at 70°F
  • Projects replacing boiler-plus-tank systems at the top of the wall-combi range

Applicability and support

Model number
INS199C
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Triangle Tube. Units are shown with every value; notes flag conflicting sources or missing figures.

Triangle Tube Instinct 199C (wall combi) specifications
SpecificationValueNote
Input
Heating input, minimum24.875 MBH24,875 to 199,000 BTU/h as printed.
Heating input, maximum199 MBH24,875 to 199,000 BTU/h as printed.
Output
DOE heating capacity184 MBHPer the product-page spec table.
Net AHRI rating159 MBHPer the product-page spec table.
Efficiency
Efficiency (AFUE)95 %95% AFUE per the product-page spec table.
Domestic hot water
Maximum DHW flow temperature150 °F (65 °C)Per the product page.
DHW output at 70°F rise5.3 GPMPer the product page.
DHW output at 75°F rise4.9 GPMPer the product page.
DHW output at 80°F rise4.6 GPMPer the product page.
DHW minimum flow0.5 GPM
DHW maximum operating pressure150 psi
Venting and air
Maximum vent length, 3"100 ftPer the product page and vent supplement 241576; the combi page prints no 2" run.
Vent/air diameter3" connection; 3-in-1 adapter accepts PVC, polypropylene or stainless steelPer the product-page spec table.
Physical and connections
Water volume4 gal
Weight130 lb
Width21.75 inThe combi cabinet is 7" taller than the wall solo.
Height33 in
Depth16.5 in
Supply/return connections1" MNPT
Gas connection3/4" MNPT
Operating limits and other
FuelNatural gas or propane
Turndown ratio8:1
Maximum CH flow temperature185 °FPer the product page.

Frequently asked questions

What DHW delivery does the Instinct 199C publish?

5.3 GPM at a 70°F temperature rise, 4.9 GPM at 75°F and 4.6 GPM at 80°F, with a 0.5 GPM minimum flow and 150 psi maximum DHW operating pressure, per the product page.

How does the 199C differ from the 155C?

The firing range tops out at 199,000 BTU/h against 155,000 BTU/h, the heating ratings rise from 142 to 184 MBH DOE capacity and 123 to 159 MBH net AHRI, and DHW delivery at a 70°F rise steps from 4.0 to 5.3 GPM. The 199C weighs 130 lb against 110 lb.

Questions about the Triangle Tube Instinct 199C (wall combi)?