Skip to content
Boilers.caby ROMA Heating & Cooling

Crown Boiler Co. · Phantom II

Crown Phantom II Combi PHTM2136C

The Crown Phantom II Combi PHTM2136C heats at 13.6 to 120 MBH input and fires 13.6 to 136 MBH for domestic hot water at 95.0% AFUE, drawing up to 3.7/3.4/2.9 GPM at 70/77/90°F rises from the small 112 lb cabinet.

CurrentCanadian status unknown

Key figures

Max input
120 MBH
Max CSA output
AFUE
95 %
Min input
13.6 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Crown Phantom II Combi PHTM2136C in practice

The PHTM2136C is the smaller Phantom II combi: space heating at 13.6–120 MBH input with a domestic hot water side firing 13.6–136 MBH, at 95.0% AFUE with 112 MBH DOE heating capacity and a 97 MBH net AHRI water rating (product ratings table; I&O manual 110331-10, 9/25). The DHW ratings table prints maximum draws of 3.7 GPM at a 70°F rise, 3.4 GPM at 77°F and 2.9 GPM at 90°F, with a 0.5 GPM minimum flow to initiate DHW demand; DHW ratings are not AHRI certified.

The combi carries the same stainless steel condensing platform and gas-adaptive 'PHTM II' control as the heat-only models (with the H10 DHW sensor fault in the diagnostics), and a low-loss header is included with the unit. It measures 16.3 × 17.8 × 29.8 inches at 112 lb shipping, connects on 1-1/4" sweat CH and 3/4" sweat DHW with 1/2" MPT gas, and vents in 2" to 70 ft or 3" with increaser to 135 ft. The DHW delivery figures decide the fit: 3.4 GPM at a 77°F rise is steady single-shower territory — a household with heavier simultaneous draws should size up to the PHTM2200C or add a tank.

Best suited to

  • Homes replacing boiler and tank with one compact 112 lb appliance
  • Households whose DHW peaks fit within the 3.4 GPM (77°F rise) continuous draw
  • Low-to-mid heat-loss homes within the 120 MBH space-heating input

Applicability and support

Model number
PHTM2136C
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Crown Boiler Co.. Units are shown with every value; notes flag conflicting sources or missing figures.

Crown Phantom II Combi PHTM2136C specifications
SpecificationValueNote
Input
Space-heating input, minimum13.6 MBHMinimum space-heating input per the ratings table (Table 3-1).
Space-heating input, maximum120 MBHMaximum space-heating input per the ratings table (Table 3-1).
DHW input, minimum13.6 MBHMinimum DHW input per the DHW ratings table.
DHW input, maximum136 MBHMaximum DHW input per the ratings table (Table 3-1, I&O manual 110331-10).
Output
DOE heating capacity112 MBHDOE heating capacity per the product ratings table.
Net AHRI water rating97 MBHNet AHRI water rating (piping and pickup allowance 1.15) per the product ratings table.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE per the product ratings table.
Domestic hot water
DHW draw at 70°F rise3.7 GPMMaximum DHW draw at a 70°F rise per the DHW ratings table (DHW ratings not AHRI certified).
DHW draw at 77°F rise3.4 GPMMaximum DHW draw at a 77°F rise per the DHW ratings table.
DHW draw at 90°F rise2.9 GPMMaximum DHW draw at a 90°F rise per the DHW ratings table.
Minimum DHW flow to initiate demand0.5 GPMMinimum DHW flow rate through the boiler to initiate DHW demand per the ratings table notes.
Domestic hot waterIntegrated combi boiler: space heating plus on-demand domestic hot water from the same applianceA low-loss header is included with the combi models; DHW ratings are not AHRI certified per the ratings table.
Venting and air
Max. equivalent vent length, 2"70 ft2" standard venting, 2.5 ft minimum; derated at maximum length per the I&O manual.
Max. equivalent vent length, 3"135 ft3" venting with increaser, 2.5 ft minimum; derated at maximum length per the I&O manual.
Physical and connections
Shipping weight112 lbApproximate shipping weight per the product ratings table.
Dimensions (D × W × H)16.3" × 17.8" × 29.8"Depth × width × height per the product dimensions table and the I&O manual (Table 3-2).
CH water connections1-1/4" sweatHeating supply/return 1-1/4" sweat per the I&O manual; the product page lists 1-1/4" MPT.
DHW connections3/4" sweatDomestic hot water connections 3/4" sweat per the I&O manual; relief valve 3/4".
Gas connection1/2" MPTGas connection 1/2" MPT per the product page.
Operating limits and other
ControlGas-adaptive 'PHTM II' controlRate-based temperature reset, PAT gas-adaptive technology and H/E-code diagnostics per the I&O manual.
FuelNatural gas or LPShips as a natural gas boiler, field convertible to LP with no conversion kit required (product page).

Frequently asked questions

How much hot water does the PHTM2136C deliver?

Up to 3.7 GPM at a 70°F rise, 3.4 GPM at 77°F and 2.9 GPM at 90°F per the DHW ratings table; real delivery falls as incoming water cools.

What is the difference between PHTM2136C and the heat-only PHTM2120H?

The combi shares the heat-only model's 13.6–120 MBH space-heating input but adds a DHW side firing 13.6–136 MBH with a low-loss header included; the heat-only model makes no domestic hot water.

Is the DHW rating AHRI certified?

No — the ratings table notes that DHW ratings are not AHRI certified, and the Net AHRI figures apply to the water (space-heating) ratings.

Questions about the Crown Phantom II Combi PHTM2136C?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate