Crown Boiler Co. · Phantom II

Crown Phantom II Combi PHTM2200C

The Crown Phantom II Combi PHTM2200C is the largest Phantom II combi: space heating at 20 to 150 MBH input plus a DHW side firing 20 to 200 MBH, drawing up to 5.2/4.7/4.0 GPM at 70/77/90°F rises, in the 135 lb large cabinet.

CurrentCanadian status unknown

Key figures

Max input
150 MBH
Max CSA output
AFUE
95 %
Min input
20 MBH
Natural gasPropaneCombiresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Crown Phantom II Combi PHTM2200C in practice

The PHTM2200C tops the Phantom II combi range: space heating at 20–150 MBH input with a domestic hot water side firing 20–200 MBH (I&O manual Table 3-1), at 95.0% AFUE with 141 MBH DOE heating capacity and a 123 MBH net AHRI water rating (product ratings table). Its DHW ratings print the strongest draws in the line — 5.2 GPM at a 70°F rise, 4.7 GPM at 77°F and 4.0 GPM at 90°F — with a 0.5 GPM minimum flow to initiate DHW demand.

The combi sits in the large 20.4 × 17.8 × 29.8 inch cabinet at 135 lb shipping, connects on 1-1/4" sweat CH and 3/4" sweat DHW with 1/2" MPT gas, includes a low-loss header, and vents in 2" to 70 ft or 3" with increaser to 135 ft (on LP above 8,000 ft this 200-size combi is limited to 50 ft equivalent). Note: the product page's DHW input row prints '13.6-136' for the PHTM2200C, but the I&O manual's Table 3-1 prints 20–200 — the manual value is used here. With a 20 MBH minimum fire it belongs in larger homes that genuinely need the heating capacity as well as the DHW volume.

Best suited to

  • Larger homes wanting one appliance for heat and high-volume hot water
  • Households whose simultaneous draws exceed the 2136C's 3.4 GPM (77°F rise) figure
  • High heat-loss homes within the 150 MBH space-heating input

Applicability and support

Model number
PHTM2200C
Canadian availability
unknown
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Crown Boiler Co.. Units are shown with every value; notes flag conflicting sources or missing figures.

Crown Phantom II Combi PHTM2200C specifications
SpecificationValueNote
Input
Space-heating input, minimum20 MBHMinimum space-heating input per the ratings table (Table 3-1).
Space-heating input, maximum150 MBHMaximum space-heating input per the ratings table (Table 3-1).
DHW input, minimum20 MBHMinimum DHW input per the ratings table (Table 3-1, I&O manual 110331-10): 20 MBH — the product page's DHW row prints '13.6-136' for this model, which the manual's Table 3-1 prints as 20–200.
DHW input, maximum200 MBHMaximum DHW input per the ratings table (Table 3-1, I&O manual 110331-10).
Output
DOE heating capacity141 MBHDOE heating capacity per the product ratings table.
Net AHRI water rating123 MBHNet AHRI water rating (piping and pickup allowance 1.15) per the product ratings table.
Efficiency
Efficiency (AFUE)95 %95.0% AFUE per the product ratings table.
Domestic hot water
DHW draw at 70°F rise5.2 GPMMaximum DHW draw at a 70°F rise per the DHW ratings table (DHW ratings not AHRI certified).
DHW draw at 77°F rise4.7 GPMMaximum DHW draw at a 77°F rise per the DHW ratings table.
DHW draw at 90°F rise4 GPMMaximum DHW draw at a 90°F rise per the DHW ratings table.
Minimum DHW flow to initiate demand0.5 GPMMinimum DHW flow rate through the boiler to initiate DHW demand per the ratings table notes.
Domestic hot waterIntegrated combi boiler: space heating plus on-demand domestic hot water from the same applianceA low-loss header is included with the combi models; DHW ratings are not AHRI certified per the ratings table.
Venting and air
Max. equivalent vent length, 2"70 ft2" standard venting, 2.5 ft minimum; derated at maximum length per the I&O manual.
Max. equivalent vent length, 3"135 ft3" venting with increaser, 2.5 ft minimum; derated at maximum length per the I&O manual.
Physical and connections
Shipping weight135 lbApproximate shipping weight per the product ratings table.
Dimensions (D × W × H)20.4" × 17.8" × 29.8"Depth × width × height per the product dimensions table and the I&O manual (Table 3-2).
CH water connections1-1/4" sweatHeating supply/return 1-1/4" sweat per the I&O manual; the product page lists 1-1/4" MPT.
DHW connections3/4" sweatDomestic hot water connections 3/4" sweat per the I&O manual; relief valve 3/4".
Gas connection1/2" MPTGas connection 1/2" MPT per the product page.
Operating limits and other
ControlGas-adaptive 'PHTM II' controlRate-based temperature reset, PAT gas-adaptive technology and H/E-code diagnostics per the I&O manual.
FuelNatural gas or LPShips as a natural gas boiler, field convertible to LP with no conversion kit required (product page).

Frequently asked questions

How much hot water does the PHTM2200C deliver?

Up to 5.2 GPM at a 70°F rise, 4.7 GPM at 77°F and 4.0 GPM at 90°F per the DHW ratings table.

Why does the product page show a different DHW input?

The product page prints '13.6-136' in the PHTM2200C DHW input row, but the I&O manual's Table 3-1 prints 20–200 for this model; Boilers.ca uses the manual value.

How does the PHTM2200C compare with the PHTM2136C?

Space heating rises from 120 to 150 MBH maximum input, DHW input from 136 to 200 MBH, and draws from 3.4 to 4.7 GPM at a 77°F rise — in the larger 20.4-inch cabinet at 135 lb against 112 lb.

Questions about the Crown Phantom II Combi PHTM2200C?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate