Crown Boiler Co. Phantom II

The Phantom II is Crown's current condensing stainless steel gas boiler line (built and sold under the Velocity Boiler Works catalogue): heat-only sizes PHTM2080H to PHTM2180H (80–180 MBH input) and combi sizes PHTM2136C and PHTM2200C, all rated 95.0% AFUE with 10:1 modulation, direct spark ignition and the gas-adaptive 'PHTM II' control.

Current seriesunknownNatural gasPropaneresidential

Series facts

Type
condensing
Efficiency
95% AFUE
Fuel
Natural gas or LP gas: the product page states the Phantom II is field convertible to LP with no conversion kit required; NG inlet gas pressure 2.5–14" w.c., LP 8–14" w.c.
Venting
Direct vent: 2" standard or 3" with increaser; minimum length 2.5 ft, maximum equivalent 70 ft in 2" (derated 6–9% at maximum length) or 135 ft in 3" (derated 1–5% at maximum length). The 150/180 heat-only sizes and the 200 combi on LP above 8,000 ft are limited to 50 ft equivalent.
Models documented
6
Warranty
Not verified

95.0% AFUE printed for every Phantom II model (heat-only PHTM2080H–2180H and combi PHTM2136C/2200C) in the product ratings tables and I&O manuals 110332-07 / 110331-10.

About the Phantom II

The Phantom II is the current-generation Crown gas condensing boiler, sold under Velocity Boiler Works (crownboiler.com redirects to velocityboilerworks.com) and listed on the current residential gas menu as 'Phantom II Heat Only' and, under Residential Combi, 'Phantom II Combi'. The heat-only menu covers four sizes — PHTM2080H, PHTM2120H, PHTM2150H and PHTM2180H (8–80 to 20–180 MBH input) — and the combi menu adds PHTM2136C and PHTM2200C, all printing 95.0% AFUE and direct-spark ignition with 10:1 modulation per the product pages.

Every Phantom II model is a stainless steel, modulating, direct-vent boiler on the gas-adaptive 'PHTM II' control (H/E-code diagnostics), with rate-based temperature reset that needs no outdoor sensor and field conversion to LP without a conversion kit. Venting is 2" standard to 70 ft or 3" with increaser to 135 ft maximum equivalent (2.5 ft minimum), with derates at maximum length and LP altitude restrictions on the largest sizes; units with an H part number are listed from 0 to 10,100 ft.

Boilers.ca documents the Phantom II at model level: heat-only models PHTM2080H, PHTM2120H, PHTM2150H and PHTM2180H, plus combi models PHTM2136C and PHTM2200C, from the official product pages and I&O manuals 110332-07 (heat only, 9/25) and 110331-10 (combi, 9/25). No official Canadian-sales statement was found, so canadianStatus stays 'unknown'; installation, gas and venting work belongs with a licensed contractor.

Highlights

  • Current Crown gas condensing line: heat-only PHTM2080H–PHTM2180H (80–180 MBH) and combi PHTM2136C / PHTM2200C
  • 95.0% AFUE across the line; modulating burner with 10:1 turndown (site copy); direct spark ignition
  • Gas-adaptive 'PHTM II' control with rate-based temperature reset (no outdoor sensor required)
  • Field convertible to LP with no conversion kit required (product page)
  • Direct vent: 2" to 70 ft or 3" with increaser to 135 ft maximum equivalent
  • Model-level pages published on Boilers.ca; I&O manuals 110332-07 and 110331-10 linked here

Models

Phantom II models

One canonical page per model with input, output and efficiency kept separate.

CurrentCanadian status unknown
Input
8–80 MBH
Output (max)
AFUE
95 %

The Crown Phantom II PHTM2080H is the smallest Phantom II heat-only boiler: 8 to 80 MBH input at 95.0% AFUE with 10:1 modulation, 75 MBH DOE heating capacity and a 65 MBH net AHRI rating, in the shared 16.3 × 17.8 × 29.8 inch cabinet.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
13.6–120 MBH
Output (max)
AFUE
95 %

The Crown Phantom II PHTM2120H fires 13.6 to 120 MBH at 95.0% AFUE with 112 MBH DOE heating capacity and a 97 MBH net AHRI rating, keeping the same 16.3 × 17.8 × 29.8 inch cabinet as the 2080H at 112 lb shipping.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
20–150 MBH
Output (max)
AFUE
95 %

The Crown Phantom II PHTM2150H fires 20 to 150 MBH at 95.0% AFUE with 141 MBH DOE heating capacity and a 123 MBH net AHRI rating, stepping to the deeper 20.4-inch cabinet at 132 lb shipping.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
20–180 MBH
Output (max)
AFUE
95 %

The Crown Phantom II PHTM2180H is the largest Phantom II heat-only boiler: 20 to 180 MBH input at 95.0% AFUE with 169 MBH DOE heating capacity and a 147 MBH net AHRI rating, in the same 132 lb large cabinet as the 2150H.

Natural gasPropaneHeating-only
CurrentCanadian status unknown
Input
13.6–120 MBH
Output (max)
AFUE
95 %

The Crown Phantom II Combi PHTM2136C heats at 13.6 to 120 MBH input and fires 13.6 to 136 MBH for domestic hot water at 95.0% AFUE, drawing up to 3.7/3.4/2.9 GPM at 70/77/90°F rises from the small 112 lb cabinet.

Natural gasPropaneCombi
CurrentCanadian status unknown
Input
20–150 MBH
Output (max)
AFUE
95 %

The Crown Phantom II Combi PHTM2200C is the largest Phantom II combi: space heating at 20 to 150 MBH input plus a DHW side firing 20 to 200 MBH, drawing up to 5.2/4.7/4.0 GPM at 70/77/90°F rises, in the 135 lb large cabinet.

Natural gasPropaneCombi

Compare models in this series

Comparison of Crown Phantom II PHTM2080H and Crown Phantom II PHTM2120H and Crown Phantom II PHTM2150H and Crown Phantom II PHTM2180H and Crown Phantom II Combi PHTM2136C and Crown Phantom II Combi PHTM2200C
SpecificationCrown Phantom II PHTM2080HCrown Phantom II PHTM2120HCrown Phantom II PHTM2150HCrown Phantom II PHTM2180HCrown Phantom II Combi PHTM2136CCrown Phantom II Combi PHTM2200C
Input, minimum8 MBH13.6 MBH20 MBH20 MBH13.6 MBH20 MBH
Input, maximum80 MBH120 MBH150 MBH180 MBH120 MBH150 MBH
output-max
Efficiency (AFUE)95 %95 %95 %95 %95 %95 %
Turndown ratio10:110:110:110:1
Max. equivalent vent length, 3"135 ft135 ft135 ft135 ft135 ft135 ft
Max. equivalent vent length, 2"70 ft70 ft70 ft70 ft70 ft70 ft
Shipping weight107 lb112 lb132 lb132 lb112 lb135 lb

Read the full comparison: Crown Phantom II PHTM2080H vs PHTM2120H

Read the full comparison: Crown Phantom II PHTM2120H vs PHTM2150H

Read the full comparison: Crown Phantom II PHTM2150H vs PHTM2180H

Read the full comparison: Crown Phantom II Combi PHTM2136C vs PHTM2200C

Read the full comparison: Crown Phantom II PHTM2180H vs HTP UFT-199W

Error codes and alerts

Phantom II alerts

  • H01Phantom II control (H01–H32 / E04–E29 codes)
  • H02Phantom II control (H01–H32 / E04–E29 codes)
  • H04Phantom II control (H01–H32 / E04–E29 codes)
  • E04Phantom II control (H01–H32 / E04–E29 codes)
  • H05Phantom II control (H01–H32 / E04–E29 codes)
  • E05Phantom II control (H01–H32 / E04–E29 codes)
  • H06Phantom II control (H01–H32 / E04–E29 codes)
  • E06Phantom II control (H01–H32 / E04–E29 codes)
  • H07Phantom II control (H01–H32 / E04–E29 codes)
  • E07Phantom II control (H01–H32 / E04–E29 codes)
  • H08Phantom II control (H01–H32 / E04–E29 codes)
  • H09Phantom II control (H01–H32 / E04–E29 codes)
  • E09Phantom II control (H01–H32 / E04–E29 codes)
  • H11Phantom II control (H01–H32 / E04–E29 codes)
  • E11Phantom II control (H01–H32 / E04–E29 codes)
  • H12Phantom II control (H01–H32 / E04–E29 codes)
  • H13Phantom II control (H01–H32 / E04–E29 codes)
  • H14Phantom II control (H01–H32 / E04–E29 codes)
  • E15Phantom II control (H01–H32 / E04–E29 codes)
  • H16Phantom II control (H01–H32 / E04–E29 codes)
  • E16Phantom II control (H01–H32 / E04–E29 codes)
  • H17Phantom II control (H01–H32 / E04–E29 codes)
  • E17Phantom II control (H01–H32 / E04–E29 codes)
  • H18Phantom II control (H01–H32 / E04–E29 codes)
  • E18Phantom II control (H01–H32 / E04–E29 codes)
  • E19Phantom II control (H01–H32 / E04–E29 codes)
  • H20Phantom II control (H01–H32 / E04–E29 codes)
  • E20Phantom II control (H01–H32 / E04–E29 codes)
  • H21Phantom II control (H01–H32 / E04–E29 codes)
  • E21Phantom II control (H01–H32 / E04–E29 codes)
  • H22Phantom II control (H01–H32 / E04–E29 codes)
  • E22Phantom II control (H01–H32 / E04–E29 codes)
  • H23Phantom II control (H01–H32 / E04–E29 codes)
  • E23Phantom II control (H01–H32 / E04–E29 codes)
  • H24Phantom II control (H01–H32 / E04–E29 codes)
  • E24Phantom II control (H01–H32 / E04–E29 codes)
  • H25Phantom II control (H01–H32 / E04–E29 codes)
  • E25Phantom II control (H01–H32 / E04–E29 codes)
  • H26Phantom II control (H01–H32 / E04–E29 codes)
  • E26Phantom II control (H01–H32 / E04–E29 codes)
  • H27Phantom II control (H01–H32 / E04–E29 codes)
  • H28Phantom II control (H01–H32 / E04–E29 codes)
  • E29Phantom II control (H01–H32 / E04–E29 codes)
  • H30Phantom II control (H01–H32 / E04–E29 codes)
  • H31Phantom II control (H01–H32 / E04–E29 codes)
  • H32Phantom II control (H01–H32 / E04–E29 codes)
  • H10Phantom II control (H01–H32 / E04–E29 codes)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the Phantom II available in Canada?

No official Canadian-sales statement was found on the official pages, so canadianStatus is recorded as 'unknown'. Boilers.ca documents the series for information and service planning; confirm supply through a licensed distributor.

What is the difference between the Phantom II heat-only and combi models?

The heat-only models (PHTM2080H–PHTM2180H) produce space heating only; the combi models (PHTM2136C, PHTM2200C) add an integrated domestic hot water function with DHW draw ratings and a minimum 0.5 GPM flow to initiate DHW demand, per the ratings tables.

Does the Phantom II replace the original Phantom?

Yes. The original Phantom generations are documented as legacy on the official manuals page, and the current catalogue lists the family as Phantom II Heat Only and Phantom II Combi (plus Phantom-X 210-285) — the generations Boilers.ca documents at model level.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 8, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate