Crown Phantom II PHTM2080H
The Crown Phantom II PHTM2080H is the smallest Phantom II heat-only boiler: 8 to 80 MBH input at 95.0% AFUE with 10:1 modulation, 75 MBH DOE heating capacity and a 65 MBH net AHRI rating, in the shared 16.3 × 17.8 × 29.8 inch cabinet.
Key figures
- Max input
- 80 MBH
- Max CSA output
- —
- AFUE
- 95 %
- Min input
- 8 MBH
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Crown Phantom II PHTM2080H in practice
The PHTM2080H opens the Phantom II heat-only range at 8–80 MBH input with 75 MBH DOE heating capacity and a 65 MBH net AHRI water rating at 95.0% AFUE (product ratings table; I&O manual 110332-07, 9/25). It is a stainless steel, modulating, direct-vent condensing boiler with direct spark ignition and a gas-adaptive 'PHTM II' control whose rate-based temperature reset needs no outdoor sensor. Above 2,000 ft its minimum input rises to 10 MBH; units with an H part number are listed to 10,100 ft.
The boiler weighs 107 lb shipping with 0.5 gal of water content, measures 16.3 × 17.8 × 29.8 inches (D × W × H), and connects on 1" sweat supply/return with 1/2" MPT gas at 50 psig MAWP. Venting is 2" standard to 70 ft or 3" with increaser to 135 ft maximum equivalent (2.5 ft minimum, derates at maximum length), and the electrical load is 120 VAC/60 Hz/1-phase at 1.8 A. It is heating-only — domestic hot water comes from a separate tank — and the product page prints the model number as PHNTM2080H while the manual prints PHTM2080H.
Best suited to
- Compact homes with low calculated heat loss within the 80 MBH input ceiling
- Buyers wanting the Phantom II family's lowest minimum fire (8 MBH at sea level)
- Projects where rate-based reset (no outdoor sensor) simplifies controls
Applicability and support
- Model number
- PHTM2080H
- Canadian availability
- unknown
- Production status
- current
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Crown Boiler Co.. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| Input, minimum | 8 MBH | Minimum input per the space-heating ratings table; above 2,000 ft the PHTM2080H minimum input rises to 10 MBH (manual note). |
| Input, maximum | 80 MBH | Maximum input per the space-heating ratings table (product page; Table 3-1). |
| Output | ||
| DOE heating capacity | 75 MBH | DOE heating capacity per the product ratings table. |
| Net AHRI water rating | 65 MBH | Net AHRI water rating based on a piping and pickup allowance of 1.15, per the product ratings table. |
| Efficiency | ||
| Efficiency (AFUE) | 95 % | 95.0% AFUE per the product ratings table. |
| Domestic hot water | ||
| Domestic hot water | Heating-only boiler — domestic hot water comes from a separate indirect tank or water heater | |
| Venting and air | ||
| Max. equivalent vent length, 2" | 70 ft | 2" standard venting, 2.5 ft minimum; derated 6–9% at maximum length. See I&O manual Table 3-3. |
| Max. equivalent vent length, 3" | 135 ft | 3" venting with increaser, 2.5 ft minimum; derated 1–5% at maximum length. See I&O manual Table 3-3. |
| Physical and connections | ||
| Boiler water content | 0.5 gal | Water content per the I&O manual specifications. |
| Shipping weight | 107 lb | Approximate shipping weight per the product ratings table. |
| Dimensions (D × W × H) | 16.3" × 17.8" × 29.8" | Depth × width × height per the product dimensions table and the I&O manual (Table 3-2). |
| Heating water connections | 1" sweat | Supply and return 1" sweat per the product page and I&O manual (Table 3-2). |
| Gas connection | 1/2" MPT | Gas connection 1/2" MPT per the product page. |
| Electrical | ||
| Electrical | 120 VAC, 60 Hz, 1-phase, 1.8 A | Boiler and pump draw per the I&O manual electrical requirements. |
| Operating limits and other | ||
| Turndown ratio | 10:1 | Product-page copy: modulating burner with 10:1 turndown ratio. |
| Maximum allowable working pressure (MAWP) | 50 psig | 50 psig maximum allowable working pressure per the I&O manual (Table 3-2). |
| Control | Gas-adaptive 'PHTM II' control with rate-based temperature reset | Rate-based reset needs no outdoor sensor; PAT gas-adaptive technology; H/E-code diagnostics per the I&O manual. |
| Fuel | Natural gas or LP | Ships as a natural gas boiler, field convertible to LP with no conversion kit required (product page). NG inlet 2.5–14" w.c.; LP inlet 8–14" w.c. |
Manuals
Alerts documented for this model
Frequently asked questions
What are the PHTM2080H's ratings?
8–80 MBH input, 75 MBH DOE heating capacity, a 65 MBH net AHRI water rating and 95.0% AFUE per the product ratings table.
Is the PHTM2080H a combi boiler?
No — it is heat-only. Domestic hot water comes from a separate indirect tank or water heater; the combi models are PHTM2136C and PHTM2200C.
Why does the manual print PHTM2080H when the page says PHNTM2080H?
The product page prints PHNTM2xxxH-style numbers while the I&O manual (110332-07) prints PHTM2080H for the same units; the model number used here follows the manual/ratings data.
Questions about the Crown Phantom II PHTM2080H?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.