Skip to content
Boilers.caby ROMA Heating & Cooling

Lochinvar · Series

Lochinvar Knight Wall Mount (WHB)

The Knight Wall Mount (WHB) is Lochinvar's wall-hung stainless steel fire-tube condensing boiler: seven models from WHB055 to WHB399 firing as low as 8.3 MBH, rated 95% AFUE (thermal efficiency on the 399) and controlled by the text-fault SMART SYSTEM.

Current seriesSold in CanadaNatural gasPropaneresidentialcommercial

Series facts

Type
condensing
Efficiency
95% AFUE
Fuel
Natural gas or propane; the ratings tables name natural gas with "N" and propane with "L" (Knight and Noble) or with an N-to-L change (Noble NKB).
Venting
Category IV sealed combustion; PVC, CPVC, polypropylene or stainless steel per the I&O manual — 055-110 sizes use 2" or 3" pipe, the 155/199 use 3", the 285 uses 3" or 4" and the 399 uses 4", each to its own maximum equivalent length. In Canada, plastic venting must be a ULC S636-certified system.
Models documented
7

95% AFUE published for the 055-285 sizes; the WHB399 is rated by thermal efficiency (94.4%) rather than AFUE.

About the Knight Wall Mount (WHB)

The Knight Wall Mount (WHB) is one half of Lochinvar's current residential Knight fire-tube line, alongside the floor-standing KHB: both use a stainless steel fire tube heat exchanger, an ECM variable-speed boiler pump, a 110 V convenience outlet and the SMART SYSTEM operating control with CON·X·US remote capability. Seven wall models span WHB055 through WHB399, with the I&O ratings table printing minimum inputs from 8.3 MBH (WHB055) to 39.9 MBH (WHB399, Series 120/121) and maximums from 55 to 399 MBH.

Efficiency is 95% AFUE across the 055-285 sizes; the WHB399 is rated by thermal efficiency (94.4%) rather than AFUE, per the same ratings table. The SMART SYSTEM reports faults as text names on the display — messages such as Flame Fail Ign, Gas Pressure SW and Outlet ARHL — rather than numeric codes, and Boilers.ca documents each fault name against the WHB service manual. Because the Knight is a heating boiler, domestic hot water comes from an indirect tank such as Lochinvar's Squire, which the residential boilers page pairs with the Knight.

Highlights

  • Wall-hung stainless steel fire-tube condensing boiler, WHB055-399
  • SMART SYSTEM control with CON·X·US; faults shown as text names, not numeric codes
  • 95% AFUE on the 055-285 sizes; WHB399 rated by 94.4% thermal efficiency
  • ECM variable-speed boiler pump and 110 V convenience outlet
  • 2"-4" venting per model; ULC S636-required plastic venting in Canada
  • 15-yr heat exchanger and 5-yr parts warranty printed on the product page

Lochinvar's product page prints a 15-year heat exchanger warranty and a 5-year parts warranty for the Knight fire tube boiler.

Models

Knight Wall Mount (WHB) models

One canonical page per model with input, output and efficiency kept separate.

CurrentSold in Canada
Input
8.3–55 MBH
Output (max)
—
AFUE
95 %

The Knight WHB055 is the entry size of Lochinvar's wall-hung fire-tube Knight: 8.3 to 55 MBH input at 95% AFUE, with 1" water connections and 2" venting to 80 equivalent feet.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
8.5–85 MBH
Output (max)
—
AFUE
95 %

The Knight WHB085 steps the wall-hung Knight to 8.5 to 85 MBH input at 95% AFUE, with 79 MBH DOE capacity and a 2.2-gallon water content in the same 1"-connection cabinet family.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
11–110 MBH
Output (max)
—
AFUE
95 %

The Knight WHB110 is the mid-size wall-hung Knight: 11 to 110 MBH input at 95% AFUE with 102 MBH DOE heating capacity, and 2" venting limited to 40 equivalent feet.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
15.5–155 MBH
Output (max)
—
AFUE
95 %

The Knight WHB155 reaches 15.5 to 155 MBH input at 95% AFUE with 144 MBH DOE capacity, and from this size upward the Knight vents in 3" pipe only.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
—
AFUE
95 %

The Knight WHB199 is the 199 MBH wall-hung Knight: 19.9 to 199 MBH input at 95% AFUE, stepping up to 1 1/4" water connections and 3" venting to 100 equivalent feet.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
28.5–285 MBH
Output (max)
—
AFUE
95 %

The Knight WHB285 is the 285 MBH wall-hung Knight: 28.5 to 285 MBH input at 95% AFUE with 264 MBH DOE capacity, 4" venting available to 100 equivalent feet and 1-1/4" connections.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
39.9–399 MBH
Output (max)
—
AFUE
—

The Knight WHB399 tops the wall-hung Knight line at 399 MBH of input and 377 MBH DOE capacity, rated by 94.4% thermal efficiency rather than AFUE, with 1-1/2" connections and 4" venting.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Lochinvar Knight WHB055 and Lochinvar Knight WHB085 and Lochinvar Knight WHB110 and Lochinvar Knight WHB155 and Lochinvar Knight WHB199 and Lochinvar Knight WHB285 and Lochinvar Knight WHB399
SpecificationLochinvar Knight WHB055Lochinvar Knight WHB085Lochinvar Knight WHB110Lochinvar Knight WHB155Lochinvar Knight WHB199Lochinvar Knight WHB285Lochinvar Knight WHB399
Heating input, minimum8.3 MBH8.5 MBH11 MBH15.5 MBH19.9 MBH28.5 MBH39.9 MBH
Heating input, maximum55 MBH85 MBH110 MBH155 MBH199 MBH285 MBH399 MBH
output-max———————
Efficiency (AFUE)95 %95 %95 %95 %95 %95 %—
turndown———————
Max. equivalent vent/air length, 3"100 ft100 ft100 ft100 ft100 ft50 ft—
Max. equivalent vent/air length, 2"80 ft50 ft40 ft————
Shipping weight169 lb——————

Read the full comparison: Lochinvar Knight WHB055 vs WHB085 →

Read the full comparison: Lochinvar Knight WHB085 vs WHB110 →

Read the full comparison: Lochinvar Knight WHB110 vs WHB155 →

Read the full comparison: Lochinvar Knight WHB155 vs WHB199 →

Read the full comparison: Lochinvar Knight WHB199 vs WHB285 →

Read the full comparison: IBC SL 14-115 G3 vs Lochinvar Knight WHB110 →

Read the full comparison: IBC SL 30-199 G3 vs Lochinvar Knight WHB199 →

Read the full comparison: Weil-McLain ECO Tec 150-H vs Lochinvar Knight WHB155 →

Error codes and alerts

Knight Wall Mount (WHB) alerts

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What is the difference between the Knight WHB and KHB?

They share the same fire-tube heat exchanger, ratings and SMART SYSTEM control: the WHB models hang on a wall and span WHB055-399, while the KHB models stand on the floor and span KHB055-285. Ratings for the shared sizes are the same in the two installation manuals.

How does the WHB show fault information?

The SMART SYSTEM display shows text-name fault messages such as Flame Fail Ign, Gas Pressure SW, Outlet ARHL or Delta T High instead of numeric error codes. Boilers.ca documents each fault name against the WHB service manual's fault tables.

Does the Knight WHB produce domestic hot water?

No. It is a heating-only boiler, and Lochinvar's residential boilers page packages it with the Squire indirect water heater. Domestic hot water is stored in that tank and reheated by the boiler on demand.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate