NTI Trinity FTVN 6 02 — Exhaust Temperature Exceeded 204f (the Error Can Only Be Cleared when the Flue Temperature Drops Below 149f)

6 02

Needs attentionNTI Trinity FTVN Series II boilers and combis (Series II control, I&O 420012001400)

Exhaust Temperature exceeded 204F (the error can only be cleared when the flue temperature drops below 149F). The exhaust temperature exceeded 204F and the error only clears once the flue temperature drops below 149F; likely causes are inadequate water flow, a dirty combustion chamber, water scaling, faulty wiring, a faulty sensor, missing or damaged refractory, and a clogged condensate drain. The table classifies it as Blocking (Manual Reset).

Applies to

This venting or air-supply fault code is displayed by the FTVN Series II control on FTVN Series II models (FTVN085, FTVN110, FTVN150, FTVN199 and combis FTVN110C, FTVN150C, FTVN199C), as documented in FTVN Series II Installation Startup Maintenance Instructions, doc 420012001400 Rev 10, Part 13-B Boiler Error Codes (420012001400 Rev 10). Codes can differ between controller generations, so always check the manual that matches your unit.

Controller: FTVN Series II control. Source manual: 420012001400 Rev 10 (2024-06-15).

Why a code is not a diagnosis

A venting or air-supply code points at the combustion-air path: a blocked terminal, a restricted flue, a failed fan, or a condensate restriction. It does not say which, and running an appliance with a blocked flue is unsafe.

Safe things to observe

  • If a carbon-monoxide alarm sounds anywhere in the building, leave immediately and call 911 from outside.
  • From a safe distance, check that the vent terminal and combustion-air inlet are not blocked.
  • Do not run the appliance while a blockage is suspected.

Do not

  • Do not put anything into the vent or air-intake openings.
  • Do not remove or modify vent pipe.

How professional service helps

  1. A technician inspects the full vent and combustion-air path, clears blockages and checks the fan.
  2. Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Parts and service

Parts commonly involved

These parts appear in the documented text for this alert. A code reports a condition, not a failed part — a technician confirms the cause by testing before anything is replaced.

Service for this alert

  • Gas Boiler Repair

    Licensed gas technicians from ROMA Heating & Cooling diagnose and repair residential and light-commercial gas boilers across…

Every boiler part explained — what it does, how it fails and what a technician checks.

Documented for NTI Boilers Trinity FTVN.

Frequently asked questions

Is this code a carbon-monoxide danger?

The code relates to combustion or venting, so treat any CO alarm as an emergency and call 911 from outside. The appliance itself should be checked by a technician before it runs again.

Can I clear this code myself?

Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.

Boiler locked out? Call with the alert text ready.

The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate