NTI Boilers · Series

NTI Boilers Trinity FTVN

The Trinity FTVN is NTI's wall-hung residential condensing boiler family, sold in heating-only and combi versions from 85 to 199 MBH. Series I and Series II share the same hardware family; Series II adds a new user interface and its own model codes, and both generations' display codes are documented on Boilers.ca.

Current seriesSold in CanadaNatural gasPropaneresidential

Series facts

Type
condensing
Efficiency
96% AFUE
Fuel
Natural gas or propane; NTI publishes separate LP conversion instructions for the FTVN series.
Venting
2" or 3" PVC/PPs venting: 2" runs up to 100 ft and 3" runs up to 150 ft per the I&O manual (the 2" terms on the 199 models follow NTI technical bulletin 2022-10-26).
Models documented
7
Warranty
Not verified

96% AFUE on the FTVN085; 95% on the other models (page headline copy says "up to 96%").

About the Trinity FTVN

The FTVN is a wall-hung, fully condensing boiler built around a vertical, down-fired stainless steel heat exchanger, with 10:1 modulation, an integrated ECM pump and a DHW diverter on the combi versions. NTI's spec table lists the FTVN085, FTVN110, FTVN150 and FTVN199 heating-only models and the FTVN110C, FTVN150C and FTVN199C combis, with the same space-heating inputs on the C models as on their heating-only counterparts (11–110, 15–150 and 19.9–199 MBH respectively).

NTI sells the FTVN in two generations. The FTVN Series I uses the earlier display and the Series II adds a new user interface with an easy setup wizard plus new model codes (3314309–3314315), while the published inputs, AFUE ratings, weights and venting terms are the same on both pages. Both generations' manuals are cited on Boilers.ca, and their numeric display codes are documented per manual generation because the two controls group codes slightly differently.

Efficiency across the family is 96% AFUE on the FTVN085 and 95% on the other models, although the page headline copy says "up to 96%". The combi models deliver continuous DHW at a 77°F rise of 2.7 GPM (FTVN110C), 3.6 GPM (FTVN150C) and 4.8 GPM (FTVN199C), which is how a BC installer decides between a combi and a heating-only FTVN paired with an indirect tank.

Highlights

  • Wall-hung residential condensing boiler family, 85 to 199 MBH input
  • Heating-only models plus FTVN110C / FTVN150C / FTVN199C combis
  • Vertical down-fired stainless steel heat exchanger with 10:1 modulation
  • 96% AFUE on the FTVN085; 95% on the other models (per the spec table)
  • Series II: new user interface, setup wizard and model codes 3314309–3314315
  • 2" venting to 100 ft or 3" to 150 ft; restricted 2" terms on the 199 models

Models

Trinity FTVN models

One canonical page per model with input, output and efficiency kept separate.

CurrentSold in Canada
Input
8.5–85 MBH
Output (max)
AFUE
96 %

The NTI Trinity FTVN085 is the entry point of the FTVN wall-hung condensing family: 8.5 to 85 MBH input at 96% AFUE — the only FTVN rated 96% — in a 107 lb heating-only boiler that also accepts 2" venting to 100 ft for retrofit-friendly runs.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
11–110 MBH
Output (max)
AFUE
95 %

The NTI Trinity FTVN110 is the 95% AFUE mid-size heating-only member of the FTVN wall-hung family, firing 11 to 110 MBH in the same 107 lb cabinet as the FTVN085, with 2" venting to 100 ft or 3" to 150 ft per side.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
15–150 MBH
Output (max)
AFUE
95 %

The NTI Trinity FTVN150 is the 95% AFUE heating-only FTVN for homes between the 110 and 199 sizes: it fires 15 to 150 MBH, weighs 122 lb, and keeps 2" venting to 100 ft or 3" to 150 ft per side.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
AFUE
95 %

The NTI Trinity FTVN199 is the largest heating-only FTVN: 19.9 to 199 MBH input at 95% AFUE in a 139.5 lb wall-hung boiler. Its 2" venting terms follow NTI technical bulletin 2022-10-26, so most installations run 3" to the 150 ft limit.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
11–110 MBH
Output (max)
AFUE
95 %

The NTI Trinity FTVN110C is the smallest FTVN combi: it heats at 11 to 110 MBH input and delivers 2.7 GPM of continuous domestic hot water at a 77°F rise, all in the same 107 lb wall-hung cabinet as the heating-only FTVN110.

Natural gasPropaneCombi
CurrentSold in Canada
Input
15–150 MBH
Output (max)
AFUE
95 %

The NTI Trinity FTVN150C is the mid-size FTVN combi: space heating from 15 to 150 MBH input plus 3.6 GPM of continuous DHW at a 77°F rise, at 95% AFUE, in a 128.5 lb wall-hung unit.

Natural gasPropaneCombi
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
AFUE
95 %

The NTI Trinity FTVN199C is the largest FTVN combi: heating at 19.9 to 199 MBH input with 4.8 GPM continuous DHW at a 77°F rise, rated 95% AFUE. Its 2" venting terms follow NTI technical bulletin 2022-10-26, so plan on 3" pipe.

Natural gasPropaneCombi

Compare models in this series

Comparison of NTI Trinity FTVN085 and NTI Trinity FTVN110 and NTI Trinity FTVN150 and NTI Trinity FTVN199 and NTI Trinity FTVN110C and NTI Trinity FTVN150C and NTI Trinity FTVN199C
SpecificationNTI Trinity FTVN085NTI Trinity FTVN110NTI Trinity FTVN150NTI Trinity FTVN199NTI Trinity FTVN110CNTI Trinity FTVN150CNTI Trinity FTVN199C
Input, minimum8.5 MBH11 MBH15 MBH19.9 MBH11 MBH15 MBH19.9 MBH
Input, maximum85 MBH110 MBH150 MBH199 MBH110 MBH150 MBH199 MBH
output-max
Efficiency (AFUE)96 %95 %95 %95 %95 %95 %95 %
Turndown ratioup to 10:1up to 10:1up to 10:1up to 10:1up to 10:1up to 10:1up to 10:1
Max. equivalent vent length, 3"150 ft150 ft150 ft150 ft150 ft150 ft150 ft
Max. equivalent vent length, 2"100 ft100 ft100 ft100 ft100 ft100 ft100 ft
Weight107 lb107 lb122 lb139.5 lb107 lb128.5 lb140.5 lb

Read the full comparison: NTI Trinity FTVN085 vs FTVN110

Read the full comparison: NTI Trinity FTVN110 vs FTVN150

Read the full comparison: NTI Trinity FTVN150 vs FTVN199

Read the full comparison: NTI Trinity FTVN110C vs FTVN150C

Read the full comparison: NTI Trinity FTVN150C vs FTVN199C

Read the full comparison: IBC SL 14-115 G3 vs NTI Trinity FTVN150

Read the full comparison: IBC SFC 99-1 Superflow vs NTI Trinity FTVN110C

Read the full comparison: Navien NCB-240/110H vs NTI Trinity FTVN110C

Error codes and alerts

Trinity FTVN alerts

  • 1 01FTVN Series I control
  • 1 03FTVN Series I control
  • 1 04FTVN Series I control
  • 1 05FTVN Series I control
  • 1 06FTVN Series I control
  • 1 07FTVN Series I control
  • 1 08FTVN Series I control
  • 1 10FTVN Series I control
  • 1 12FTVN Series I control
  • 1 14FTVN Series I control
  • 1 15FTVN Series I control
  • 1 16FTVN Series I control
  • 1 50FTVN Series I control
  • 1 P1FTVN Series I control
  • 1 P2FTVN Series I control
  • 1 P3FTVN Series I control
  • 2 01FTVN Series I control
  • 2 03FTVN Series I control
  • 2 05FTVN Series I control
  • 2 09FTVN Series I control
  • 2 P2FTVN Series I control
  • 3 01FTVN Series I control
  • 3 02FTVN Series I control
  • 3 03FTVN Series I control
  • 3 04FTVN Series I control
  • 3 05FTVN Series I control
  • 3 06FTVN Series I control
  • 3 07FTVN Series I control
  • 3 09FTVN Series I control
  • 3 P9FTVN Series I control
  • 4 11FTVN Series I control
  • 4 12FTVN Series I control
  • 4 13FTVN Series I control
  • 4 30FTVN Series I control
  • 4 31FTVN Series I control
  • 4 40FTVN Series I control
  • 4 41FTVN Series I control
  • 5 01FTVN Series I control
  • 5 02FTVN Series I control
  • 5 04FTVN Series I control
  • 5 P1FTVN Series I control
  • 5 P2FTVN Series I control
  • 5 P6FTVN Series I control
  • 5 P3FTVN Series I control
  • 6 02FTVN Series I control
  • 6 03FTVN Series I control
  • 6 05FTVN Series I control
  • 6 12FTVN Series I control
  • 6 19FTVN Series I control
  • NOAVLFTVN Series I control
  • EMERGFTVN Series I control
  • CONFLFTVN Series I control
  • 1 01FTVN Series II control
  • 1 02FTVN Series II control
  • 1 03FTVN Series II control
  • 1 04FTVN Series II control
  • 1 05FTVN Series II control
  • 1 06FTVN Series II control
  • 1 07FTVN Series II control
  • 1 08FTVN Series II control
  • 1 10FTVN Series II control
  • 1 12FTVN Series II control
  • 1 14FTVN Series II control
  • 1 15FTVN Series II control
  • 1 16FTVN Series II control
  • 1 50FTVN Series II control
  • 1 P1FTVN Series II control
  • 1 P2FTVN Series II control
  • 1 P3FTVN Series II control
  • 2 01FTVN Series II control
  • 2 03FTVN Series II control
  • 2 05FTVN Series II control
  • 2 09FTVN Series II control
  • 2 P2FTVN Series II control
  • 3 01FTVN Series II control
  • 3 02FTVN Series II control
  • 3 03FTVN Series II control
  • 3 04FTVN Series II control
  • 3 05FTVN Series II control
  • 3 06FTVN Series II control
  • 3 07FTVN Series II control
  • 3 09FTVN Series II control
  • 3 11FTVN Series II control
  • 3 P9FTVN Series II control
  • 4 11FTVN Series II control
  • 4 12FTVN Series II control
  • 4 13FTVN Series II control
  • 4 30FTVN Series II control
  • 4 31FTVN Series II control
  • 4 40FTVN Series II control
  • 4 41FTVN Series II control
  • 5 01FTVN Series II control
  • 5 02FTVN Series II control
  • 5 04FTVN Series II control
  • 5 P1FTVN Series II control
  • 5 P2FTVN Series II control
  • 5 P6FTVN Series II control
  • 5 P3FTVN Series II control
  • 6 02FTVN Series II control
  • 6 03FTVN Series II control
  • 6 05FTVN Series II control
  • 6 12FTVN Series II control
  • 6 19FTVN Series II control
  • NOAVLFTVN Series II control
  • EMERGFTVN Series II control
  • CONFLFTVN Series II control

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What changed between the FTVN Series I and Series II?

NTI describes the Series II as the same hardware family with a new user interface and easy setup wizard, plus new model codes (3314309–3314315). Published inputs, AFUE, weights and venting terms are identical on the two pages, and each generation has its own I&O manual.

Which FTVN models provide domestic hot water?

The FTVN110C, FTVN150C and FTVN199C are combis with an integrated DHW plate in the appliance. NTI rates their continuous DHW capacity at 2.7, 3.6 and 4.8 GPM at a 77°F rise respectively.

What do the numeric codes on an FTVN display mean?

NTI groups codes by circuit: 1xx covers the primary (central heat) circuit, 2xx the DHW circuit, 3xx internal electronics, 4xx external electronics, 5xx ignition and detection, 6xx air and flue, and 7xx multi-zone. Boilers.ca documents each generation's table from its own manual.