Skip to content
Boilers.caby ROMA Heating & Cooling

NTI Boilers · Series

NTI Boilers Trinity TFTN

The Trinity TFTN is NTI's next-generation flagship boiler line: wall-hung condensing models from the TFTN085 to the TFTN399 with a full-colour touchscreen, built-in Wi-Fi, low-water cut-off and zone control, with floor-mounted TFTN500–850 sizes in the same family. Boilers.ca documents the wall-hung 085–399 and the floor-mounted 500–850 sizes as model records.

Current seriesSold in CanadaNatural gasPropaneresidentialcommercial

Series facts

Type
condensing
Efficiency
95% AFUE
Fuel
Natural gas or propane; NTI publishes LP conversion instructions for the TFTN085–199, TFTN285–399 and TFTN500–850 size groups.
Venting
2" or 3" venting on the 085–199 wall models (100 ft and 150 ft respectively); 3" only to 150 ft on the TFTN285; 4" to 150 ft on the TFTN340 and TFTN399.
Models documented
11
Warranty
Not verified

96% AFUE on the TFTN085, 95% on the 110 / 150 / 199 / 285, and 95.4% thermal efficiency on the 340 and 399 (per the NTI product page).

About the Trinity TFTN

NTI positions the TFTN as the next generation of its flagship TFT line, built on the same platform with a redesigned touchscreen control. The wall-hung models run from the TFTN085 to the TFTN399 — inputs of 8.5–85 through 39.9–399 MBH — with a full-colour graphics display, remote monitoring and diagnostics over Wi-Fi, a built-in low-water cut-off, a 120V convenience outlet and built-in control for up to three heating zones plus DHW.

The page's wall-mount spec table lists efficiency as 96% AFUE on the TFTN085, 95% on the 110 through 285, and 95.4% thermal efficiency on the TFTN340 and TFTN399, whose published rating is thermal rather than AFUE. Weights run from 107 lb (with water) on the 085 to 250 lb on the 340 and 399, and the water connections step from 1 1/4" NPT up to 1 1/2" NPT on the two largest wall models.

The same product page lists the floor-mounted TFTN500, TFTN600, TFTN725 and TFTN850 (50–500 through 85–850 MBH input) for larger plants. Boilers.ca documents all four floor sizes as model records beside the wall-hung 085–399 models; NTI covers them in the separate TFTN500–850 I&O manual (99987545), and rates them by thermal efficiency (98% down to 97.6%) rather than AFUE.

Highlights

  • Wall-hung flagship line: TFTN085, 110, 150, 199, 285, 340 and 399
  • Full-colour touchscreen with setup wizard, Wi-Fi and built-in low-water cut-off
  • 96% AFUE (TFTN085), 95% (110–285), 95.4% thermal (340 / 399)
  • Floor-mounted TFTN500–850 siblings in the same family
  • Built-in control for up to three heating zones plus DHW
  • Weights with water from 107 lb (TFTN085) to 250 lb (TFTN340 / 399)

Models

Trinity TFTN models

One canonical page per model with input, output and efficiency kept separate.

CurrentSold in Canada
Input
8.5–85 MBH
Output (max)
AFUE
96 %

The NTI Trinity TFTN085 is the smallest wall-hung TFTN: 8.5 to 85 MBH input, the only TFTN wall model rated 96% AFUE, weighing 107 lb with water and standing 34 1/8 inches tall with a 2" venting option to 100 ft.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
11–110 MBH
Output (max)
AFUE
95 %

The NTI Trinity TFTN110 is the 95% AFUE wall-hung TFTN between the 085 and the 150: 11 to 110 MBH input in the same 107 lb cabinet as the TFTN085, with 2" venting to 100 ft or 3" to 150 ft.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
15–150 MBH
Output (max)
AFUE
95 %

The NTI Trinity TFTN150 is the 95% AFUE wall-hung TFTN for mid-to-larger homes: 15 to 150 MBH input, 122 lb with water, on 1 1/4" NPT CH connections with 2" venting to 100 ft or 3" to 150 ft.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
19.9–199 MBH
Output (max)
AFUE
95 %

The NTI Trinity TFTN199 is the 95% AFUE wall-hung TFTN at the classic 199 MBH mark: 19.9 to 199 MBH input, 140 lb with water, still on 1 1/4" NPT CH connections with 2" venting to 100 ft or 3" to 150 ft.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
28.5–285 MBH
Output (max)
AFUE
95 %

The NTI Trinity TFTN285 is the 95% AFUE wall-hung TFTN for big houses and light-commercial plants: 28.5 to 285 MBH input, 180 lb with water, in a wider 21 3/8 inch cabinet with 3"-only venting to 150 ft.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
39.9–340 MBH
Output (max)
AFUE

The NTI Trinity TFTN340 is the first of the two largest TFTN wall models: 39.9 to 340 MBH input, rated 95.4% thermal efficiency rather than AFUE, at 250 lb with water in a 25 1/4 inch-wide cabinet with 4" venting to 150 ft.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
39.9–399 MBH
Output (max)
AFUE

The NTI Trinity TFTN399 is the largest TFTN wall model: 39.9 to 399 MBH input at 95.4% thermal efficiency, 250 lb with water, on 1 1/2" NPT CH connections with 4" venting to 150 ft — the wall-hung option NTI positions against its floor-mounted 500–850 sizes.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
50–500 MBH
Output (max)
AFUE

The NTI Trinity TFTN500 is the smallest floor-mounted TFTN: 50 to 500 MBH input at 98% thermal efficiency, with a 489 MBH heating capacity and a 425 MBH Net AHRI rating, weighing 575 lb with water on 2" NPT water connections with 4" venting to 150 ft.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
60–600 MBH
Output (max)
AFUE

The NTI Trinity TFTN600 lifts the floor-mounted TFTN to a 600 MBH ceiling: 60 to 600 MBH input at 97.8% thermal efficiency, a 585 MBH heating capacity and a 509 MBH Net AHRI rating, sharing the 575 lb with-water weight and 2" water connections of the TFTN500.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
72.5–725 MBH
Output (max)
AFUE

The NTI Trinity TFTN725 is the second-largest floor-mounted TFTN: 72.5 to 725 MBH input at 97.7% thermal efficiency, a 705 MBH heating capacity and a 613 MBH Net AHRI rating, stepping to 685 lb with water, 2 1/2" NPT water connections and 6" venting.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
85–850 MBH
Output (max)
AFUE

The NTI Trinity TFTN850 is the largest floor-mounted TFTN: 85 to 850 MBH input at 97.6% thermal efficiency, with an 825 MBH heating capacity and a 717 MBH Net AHRI rating, weighing 690 lb with water on 2 1/2" NPT water connections with 6" venting.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of NTI Trinity TFTN085 and NTI Trinity TFTN110 and NTI Trinity TFTN150 and NTI Trinity TFTN199 and NTI Trinity TFTN285 and NTI Trinity TFTN340 and NTI Trinity TFTN399 and NTI Trinity TFTN500 and NTI Trinity TFTN600 and NTI Trinity TFTN725 and NTI Trinity TFTN850
SpecificationNTI Trinity TFTN085NTI Trinity TFTN110NTI Trinity TFTN150NTI Trinity TFTN199NTI Trinity TFTN285NTI Trinity TFTN340NTI Trinity TFTN399NTI Trinity TFTN500NTI Trinity TFTN600NTI Trinity TFTN725NTI Trinity TFTN850
Input, minimum8.5 MBH11 MBH15 MBH19.9 MBH28.5 MBH39.9 MBH39.9 MBH50 MBH60 MBH72.5 MBH85 MBH
Input, maximum85 MBH110 MBH150 MBH199 MBH285 MBH340 MBH399 MBH500 MBH600 MBH725 MBH850 MBH
output-max
Efficiency (AFUE)96 %95 %95 %95 %95 %
turndown
Max. equivalent vent length150 ft150 ft150 ft150 ft150 ft150 ft150 ft
Max. equivalent vent length, 2"100 ft100 ft100 ft100 ft
Weight107 lb107 lb122 lb140 lb180 lb250 lb250 lb575 lb575 lb685 lb690 lb

Read the full comparison: NTI Trinity TFTN085 vs TFTN110

Read the full comparison: NTI Trinity TFTN110 vs TFTN150

Read the full comparison: NTI Trinity TFTN150 vs TFTN199

Read the full comparison: NTI Trinity TFTN199 vs TFTN285

Read the full comparison: NTI Trinity TFTN285 vs TFTN340

Read the full comparison: NTI Trinity TFTN340 vs TFTN399

Read the full comparison: NTI Trinity TFTN500 vs TFTN600

Read the full comparison: NTI Trinity TFTN600 vs TFTN725

Read the full comparison: NTI Trinity TFTN725 vs TFTN850

Read the full comparison: IBC SL 30-199 G3 vs NTI Trinity TFTN199

Read the full comparison: Navien NFB-200H vs NTI Trinity TFTN199

Read the full comparison: NTI Trinity TFTN150 vs Weil-McLain ECO Tec 150-H

Error codes and alerts

Trinity TFTN alerts

  • 101 1NTI HMI control (R30)
  • 102NTI HMI control (R30)
  • 103 1NTI HMI control (R30)
  • 104 1NTI HMI control (R30)
  • 105 1NTI HMI control (R30)
  • 106 1NTI HMI control (R30)
  • 109NTI HMI control (R30)
  • 110 1NTI HMI control (R30)
  • 112 1NTI HMI control (R30)
  • 113NTI HMI control (R30)
  • 114NTI HMI control (R30)
  • 115NTI HMI control (R30)
  • 117 1NTI HMI control (R30)
  • 118 1NTI HMI control (R30)
  • 150NTI HMI control (R30)
  • 1P1 1NTI HMI control (R30)
  • 1P2 1NTI HMI control (R30)
  • 1P3 1NTI HMI control (R30)
  • 1P4NTI HMI control (R30)
  • 203NTI HMI control (R30)
  • 209NTI HMI control (R30)
  • 2P2NTI HMI control (R30)
  • 303NTI HMI control (R30)
  • 304NTI HMI control (R30)
  • 306NTI HMI control (R30)
  • 309NTI HMI control (R30)
  • 3P9NTI HMI control (R30)
  • 411NTI HMI control (R30)
  • 412NTI HMI control (R30)
  • 413NTI HMI control (R30)
  • 441NTI HMI control (R30)
  • 460NTI HMI control (R30)
  • 501 1NTI HMI control (R30)
  • 502NTI HMI control (R30)
  • 504 1NTI HMI control (R30)
  • 5P1NTI HMI control (R30)
  • 5P2NTI HMI control (R30)
  • 5P6NTI HMI control (R30)
  • 5P3NTI HMI control (R30)
  • 5P5NTI HMI control (R30)
  • 602NTI HMI control (R30)
  • 603 1NTI HMI control (R30)
  • 605NTI HMI control (R30)
  • 608NTI HMI control (R30)
  • 612 1NTI HMI control (R30)
  • 730NTI HMI control (R30)
  • UnconfiguredNTI HMI control (R30)
  • ConflictNTI HMI control (R30)
  • 101 1NTI HMI control (R30)
  • 102NTI HMI control (R30)
  • 103 1NTI HMI control (R30)
  • 104 1NTI HMI control (R30)
  • 105 1NTI HMI control (R30)
  • 106 1NTI HMI control (R30)
  • 109NTI HMI control (R30)
  • 110 1NTI HMI control (R30)
  • 112 1NTI HMI control (R30)
  • 113NTI HMI control (R30)
  • 114NTI HMI control (R30)
  • 115NTI HMI control (R30)
  • 117 1NTI HMI control (R30)
  • 118 1NTI HMI control (R30)
  • 150NTI HMI control (R30)
  • 1P1 1NTI HMI control (R30)
  • 1P2 1NTI HMI control (R30)
  • 1P3 1NTI HMI control (R30)
  • 1P4NTI HMI control (R30)
  • 203NTI HMI control (R30)
  • 209NTI HMI control (R30)
  • 2P2NTI HMI control (R30)
  • 303NTI HMI control (R30)
  • 304NTI HMI control (R30)
  • 306NTI HMI control (R30)
  • 309NTI HMI control (R30)
  • 3P9NTI HMI control (R30)
  • 411/412/413NTI HMI control (R30)
  • 441NTI HMI control (R30)
  • 460NTI HMI control (R30)
  • 501 1NTI HMI control (R30)
  • 502NTI HMI control (R30)
  • 504 1NTI HMI control (R30)
  • 5P1NTI HMI control (R30)
  • 5P2NTI HMI control (R30)
  • 5P6NTI HMI control (R30)
  • 5P3NTI HMI control (R30)
  • 5P5NTI HMI control (R30)
  • 602NTI HMI control (R30)
  • 603 1NTI HMI control (R30)
  • 605NTI HMI control (R30)
  • 608NTI HMI control (R30)
  • 612 1NTI HMI control (R30)
  • 730NTI HMI control (R30)
  • UnconfiguredNTI HMI control (R30)
  • ConflictNTI HMI control (R30)

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

What is the difference between the TFTN and the TFT?

The TFT is the earlier NTI line and is listed as discontinued. NTI says the TFTN is built on the same platform as the TFT with a redesigned, easier control, onboard Wi-Fi and touchscreen.

Is the TFTN available as a floor-standing boiler?

The TFTN family includes floor-mounted TFTN500, TFTN600, TFTN725 and TFTN850 models documented in the separate 500–850 manual (99987545), sold for commercial applications. Boilers.ca documents the wall-hung 085–399 and the floor-mounted 500–850 sizes as separate model records.

How is the TFTN340 or TFTN399 rated if not by AFUE?

NTI publishes 95.4% thermal efficiency for the TFTN340 and TFTN399 in the AFUE/thermal-efficiency column of its product page. The 085 is rated 96% AFUE and the 110 through 285 models 95%.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 8, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate