Viessmann · Vitogas 050 (ECD / ECV / RS)

Viessmann Vitogas 050 ECD-115

The Vitogas 050 ECD-115 is the larger of the two four-section ECD sizes: 115 MBH input (34 kW), 95 MBH output and 83.5% AFUE.

DiscontinuedHistorically in Canada

Key figures

Max input
—
Max CSA output
—
AFUE
83.5 %
Min input
—
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitogas 050 ECD-115 in practice

The ECD-115 fires at 115 MBH (34 kW) input with 95 MBH (28 kW) output at 83.5% AFUE. It shares the four-section, three-burner chassis, 3.5 USG water content, 285 lb (130 kg) weight and 432 x 502 mm footprint with the ECD-100.

The 6 in. vent collar and 50 psig maximum operating pressure are unchanged, and the boiler runs on natural gas or propane as an atmospheric, chimney-vented cast-iron unit.

Best suited to

  • Existing ECD-115 installations needing printed ratings
  • Residential loads between the ECD-100 and ECD-140
  • Comparing the two four-section ECD sizes

Applicability and support

Model number
ECD-115
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitogas 050 ECD-115 specifications
SpecificationValueNote
Input
CSA input (natural gas)115 MBH34 kW, per the technical data manual
Output
CSA output / DOE output95 MBH28 kW
Efficiency
Efficiency (AFUE)83.5 %With intermittent pilot electronic ignition system and vent damper.
Venting and air
Vent pipe collar6 inChimney-vented with draft hood; each ECD ships with a vent damper.
Physical and connections
Weight (with insulation, burners and packaging)285 lb130 kg
Overall width432 mmPrinted as 17 in
Overall depth502 mm19¾ in
Overall height1,035 mmPrinted as 40¾ in
Operating limits and other
FuelNatural gas or propane3.5 in. w.c. manifold pressure NG; 10 in. w.c. propane.
Cast iron sections43 burners.
Boiler water content3.5 USGPer the technical data manual.
Maximum operating pressure50 psig345 kPa.
Boiler supply / return1¼ in. male threadGas supply ½ in. male thread.

Frequently asked questions

What is the ECD-115 rated at?

115 MBH (34 kW) input, 95 MBH (28 kW) output and 83.5% AFUE, with four cast-iron sections and three burners.

How does the ECD-115 differ from the ECD-100?

Only the firing rate: 115 vs 100 MBH input and 95 vs 83 MBH output. Chassis, burners, weight and dimensions are identical.

Is the ECD-115 approved for propane?

Yes. The ECD technical data manual prints manifold pressures for both natural gas (3.5 in. w.c.) and propane (10 in. w.c.).

Questions about the Viessmann Vitogas 050 ECD-115?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.