Viessmann Vitogas 050 ECD-200

The Vitogas 050 ECD-200 is the largest ECD boiler: 200 MBH input (59 kW), 166 MBH output and 83.0% AFUE — the lowest printed figure in the range.

DiscontinuedHistorically in Canada

Key figures

Max input
—
Max CSA output
—
AFUE
83 %
Min input
—
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitogas 050 ECD-200 in practice

The ECD-200 tops the ECD range at 200 MBH (59 kW) input with 166 MBH (49 kW) output and 83.0% AFUE. It shares the six-section, five-burner chassis with the ECD-180, including the 7.1 USG water content, 423 lb (192 kg) weight and 635 x 502 mm footprint.

The 7 in. vent collar and 50 psig maximum operating pressure are unchanged. Together with the ECD-S and ECV variants, the ECD-200 is part of the discontinued Vitogas 050 line documented under Viessmann Canada's historic manuals.

Best suited to

  • Existing ECD-200 installations needing printed ratings
  • The largest ECD loads at 200 MBH input
  • Comparing the ECD range against the higher-output ECV variants

Applicability and support

Model number
ECD-200
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitogas 050 ECD-200 specifications
SpecificationValueNote
Input
CSA input (natural gas)200 MBH59 kW, per the technical data manual
Output
CSA output / DOE output166 MBH49 kW
Efficiency
Efficiency (AFUE)83 %With intermittent pilot electronic ignition system and vent damper.
Venting and air
Vent pipe collar7 inChimney-vented with draft hood; each ECD ships with a vent damper.
Physical and connections
Weight (with insulation, burners and packaging)423 lb192 kg
Overall width635 mmPrinted as 25 in
Overall depth502 mm19¾ in
Overall height1,035 mmPrinted as 40¾ in
Operating limits and other
FuelNatural gas or propane3.5 in. w.c. manifold pressure NG; 10 in. w.c. propane.
Cast iron sections65 burners.
Boiler water content7.1 USGPer the technical data manual.
Maximum operating pressure50 psig345 kPa.
Boiler supply / return1¼ in. male threadGas supply ½ in. male thread.

Frequently asked questions

What is the ECD-200 rated at?

200 MBH (59 kW) input, 166 MBH (49 kW) output and 83.0% AFUE, with six cast-iron sections and five burners.

What is the difference between the ECD-200 and ECV-200?

The ECV variant prints a slightly higher 168 MBH output, a uniform 83.1% AFUE, a 430 lb (195 kg) weight and a 3 in. power-vent collar instead of the ECD's 7 in. chimney vent.

Is the ECD-200 still available?

No. The Vitogas 050 line is discontinued; documentation remains in Viessmann Canada's historic manuals downloads.

Questions about the Viessmann Vitogas 050 ECD-200?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.