Viessmann Vitogas 050 ECD-155

The Vitogas 050 ECD-155 is the larger five-section ECD size: 155 MBH input (45 kW), 129 MBH output and 83.4% AFUE.

DiscontinuedHistorically in Canada

Key figures

Max input
—
Max CSA output
—
AFUE
83.4 %
Min input
—
Natural gasPropaneHeating-onlyresidential

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitogas 050 ECD-155 in practice

The ECD-155 fires at 155 MBH (45 kW) input with 129 MBH (38 kW) output and prints 83.4% AFUE — a tenth below the smaller ECD sizes. It shares the five-section, four-burner chassis, 4.3 USG water content, 345 lb (157 kg) weight and 533 x 502 mm footprint with the ECD-140.

The 7 in. vent collar, 50 psig maximum operating pressure and atmospheric cast-iron design are unchanged, with natural gas or propane firing per the ECD technical data manual.

Best suited to

  • Existing ECD-155 installations needing printed ratings
  • Residential loads between the ECD-140 and ECD-180
  • Comparing the two five-section ECD sizes

Applicability and support

Model number
ECD-155
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitogas 050 ECD-155 specifications
SpecificationValueNote
Input
CSA input (natural gas)155 MBH45 kW, per the technical data manual
Output
CSA output / DOE output129 MBH38 kW
Efficiency
Efficiency (AFUE)83.4 %With intermittent pilot electronic ignition system and vent damper.
Venting and air
Vent pipe collar7 inChimney-vented with draft hood; each ECD ships with a vent damper.
Physical and connections
Weight (with insulation, burners and packaging)345 lb157 kg
Overall width533 mmPrinted as 21 in
Overall depth502 mm19¾ in
Overall height1,035 mmPrinted as 40¾ in
Operating limits and other
FuelNatural gas or propane3.5 in. w.c. manifold pressure NG; 10 in. w.c. propane.
Cast iron sections54 burners.
Boiler water content4.3 USGPer the technical data manual.
Maximum operating pressure50 psig345 kPa.
Boiler supply / return1¼ in. male threadGas supply ½ in. male thread.

Frequently asked questions

What is the ECD-155 rated at?

155 MBH (45 kW) input, 129 MBH (38 kW) output and 83.4% AFUE, with five cast-iron sections and four burners.

Why is the ECD-155's AFUE lower than the ECD-140's?

The technical data manual prints 83.4% for the ECD-155 against 83.5% for the ECD-140 — the figures as printed, both with intermittent pilot ignition and a vent damper.

How does the ECD-155 differ from the ECD-140?

Only the firing rate: 155 vs 140 MBH input and 129 vs 116 MBH output, in the same chassis.

Questions about the Viessmann Vitogas 050 ECD-155?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate