Skip to content
Boilers.caby ROMA Heating & Cooling

Viessmann · Vitogas 050 (ECD / ECV / RS)

Viessmann Vitogas 050 RS-11

The Vitogas 050 RS-11 is the mid-size commercial RS boiler: 800 MBH full-load input (234 kW), 680 MBH output and 85% combustion efficiency with an 11-section block.

DiscontinuedHistorically in Canada

Key figures

Max input
—
Max CSA output
—
AFUE
—
Min input
—
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitogas 050 RS-11 in practice

The RS-11 is rated 800 MBH (234 kW) full-load input, 541 MBH (158 kW) at partial load and 680 MBH (199 kW) full-load output at 85% combustion efficiency. It uses 11 cast-iron sections and 10 burners with 28 USG of boiler water at 60 psig maximum operating pressure.

Weight is 1,709 lb (777 kg) and width grows to 1,255 mm (49½ in) at the series' 883 mm depth and 1366 mm height. Connections are 2 in. supply and return, 1¼ in. gas and a 12 in. vent pipe collar.

Best suited to

  • Existing RS-11 installations needing printed ratings
  • Commercial loads between the RS-8 and RS-14
  • Documentation for 11-section RS builds

Applicability and support

Model number
RS-11
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitogas 050 RS-11 specifications
SpecificationValueNote
Input
CSA input, full load800 MBH234 kW, per the technical data manual
CSA input, partial load541 MBH158 kW; two-stage boilers only.
Output
CSA output, full load680 MBH199 kW; supply 167°F / return 140°F.
CSA output, partial load460 MBH135 kW; two-stage boilers only.
Efficiency
Combustion efficiency85 %Printed for all three RS sizes.
Venting and air
Vent pipe collar12 inOutside diameter per the technical data manual.
Physical and connections
Weight (with insulation, burners and packaging)1,709 lb777 kg
Depth883 mm34¾ in; total depth with controls 1195 mm (47 in).
Width1,255 mmTotal width per the technical data manual.
Height1,366 mm53¾ in; 1531 mm with control in operating position, 1867 mm for servicing.
Operating limits and other
FuelNatural gas or propane3.5 in. w.c. manifold pressure NG at full load; propane not available in two-stage configuration.
Cast iron sections1110 burners.
Boiler water content28 USG
Maximum operating pressure60 psig414 kPa.
Boiler supply / return2 in. male threadGas supply 1¼ in.; boiler drain ¾ in.

Frequently asked questions

What is the RS-11 rated at?

800 MBH (234 kW) full-load input, 541 MBH partial load, 680 MBH (199 kW) full-load output and 85% combustion efficiency, with 11 sections and 10 burners.

How wide is the RS-11?

1,255 mm (49½ in) overall, 883 mm (34¾ in) deep and 1366 mm (53¾ in) high, weighing 1,709 lb (777 kg).

What vent collar does the RS-11 use?

A 12 in. vent pipe collar, per the Vitogas 050 RS technical data manual.

Questions about the Viessmann Vitogas 050 RS-11?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate