Skip to content
Boilers.caby ROMA Heating & Cooling

Viessmann · Vitogas 050 (ECD / ECV / RS)

Viessmann Vitogas 050 ECD-180

The Vitogas 050 ECD-180 opens the largest ECD chassis: 180 MBH input (53 kW), 149 MBH output and 83.2% AFUE with six sections.

DiscontinuedHistorically in Canada

Key figures

Max input
—
Max CSA output
—
AFUE
83.2 %
Min input
—
Natural gasPropaneHeating-onlyresidentialcommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Viessmann Vitogas 050 ECD-180 in practice

The ECD-180 is rated 180 MBH (53 kW) input and 149 MBH (44 kW) output at 83.2% AFUE. It is the first ECD size with six cast-iron sections and five burners, holding 7.1 USG of boiler water.

Weight steps up to 423 lb (192 kg) and the cabinet widens to 635 mm (25 in) at the same 502 mm depth and 1035 mm height, with the 7 in. vent collar and 50 psig maximum operating pressure of the range.

Best suited to

  • Existing ECD-180 installations needing printed ratings
  • Larger residential loads between 155 and 200 MBH
  • Documentation for the six-section ECD chassis

Applicability and support

Model number
ECD-180
Canadian availability
historical
Production status
discontinued
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Not verified

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.

Viessmann Vitogas 050 ECD-180 specifications
SpecificationValueNote
Input
CSA input (natural gas)180 MBH53 kW, per the technical data manual
Output
CSA output / DOE output149 MBH44 kW
Efficiency
Efficiency (AFUE)83.2 %With intermittent pilot electronic ignition system and vent damper.
Venting and air
Vent pipe collar7 inChimney-vented with draft hood; each ECD ships with a vent damper.
Physical and connections
Weight (with insulation, burners and packaging)423 lb192 kg
Overall width635 mmPrinted as 25 in
Overall depth502 mm19¾ in
Overall height1,035 mmPrinted as 40¾ in
Operating limits and other
FuelNatural gas or propane3.5 in. w.c. manifold pressure NG; 10 in. w.c. propane.
Cast iron sections65 burners.
Boiler water content7.1 USGPer the technical data manual.
Maximum operating pressure50 psig345 kPa.
Boiler supply / return1¼ in. male threadGas supply ½ in. male thread.

Frequently asked questions

What is the ECD-180 rated at?

180 MBH (53 kW) input, 149 MBH (44 kW) output and 83.2% AFUE, with six cast-iron sections and five burners.

How wide is the ECD-180?

635 mm (25 in) overall, with a 502 mm (19¾ in) depth and 1035 mm (40¾ in) height at 423 lb (192 kg).

Does the ECD-180 share a chassis with the ECD-200?

Yes — both use the six-section chassis; the ECD-200 differs only in firing rate and water content.

Questions about the Viessmann Vitogas 050 ECD-180?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate