Viessmann · Vitogas 050 (ECD / ECV / RS)
Viessmann Vitogas 050 ECV-100
The Vitogas 050 ECV-100 is a four-section ECV boiler: 100 MBH input (29 kW), 84 MBH output and 83.1% AFUE with a 3 in. vent collar.
Key figures
- Max input
- —
- Max CSA output
- —
- AFUE
- 83.1 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Viessmann Vitogas 050 ECV-100 in practice
The ECV-100 is rated 100 MBH (29 kW) input and 84 MBH (25 kW) output at 83.1% AFUE. It moves to four cast-iron sections and three burners, with 3.5 USG of boiler water and a 293 lb (133 kg) weight.
The cabinet widens to 432 mm (17 in) at the series' 502 mm depth and 1030 mm height. The 3 in. vent collar and 20 ft maximum equivalent vent run apply, with 50 psig maximum operating pressure.
Best suited to
- Existing ECV-100 installations needing printed ratings
- Residential loads between the ECV-80 and ECV-115
- Documentation for four-section ECV builds
Applicability and support
- Model number
- ECV-100
- Canadian availability
- historical
- Production status
- discontinued
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| CSA input (natural gas) | 100 MBH | 29 kW, per the technical data manual |
| Output | ||
| CSA output / DOE output | 84 MBH | 25 kW |
| Efficiency | ||
| Efficiency (AFUE) | 83.1 % | Printed as 83.1% AFUE on all eight ECV sizes. |
| Venting and air | ||
| Vent pipe collar | 3 in | Maximum equivalent vent run 20 ft (6 m) with 3 in. vent pipe. |
| Physical and connections | ||
| Weight (with insulation, burners and packaging) | 293 lb | 133 kg |
| Overall width | 432 mm | Printed as 17 in |
| Overall depth | 502 mm | 19¾ in |
| Overall height | 1,030 mm | Printed as 41½ in |
| Operating limits and other | ||
| Fuel | Natural gas or propane | 3.5 in. w.c. manifold pressure NG; 10 in. w.c. propane. |
| Cast iron sections | 4 | 3 burners. |
| Boiler water content | 3.5 USG | Per the technical data manual. |
| Maximum operating pressure | 50 psig | 345 kPa. |
| Boiler supply / return | 1¼ in. male thread | Gas supply ½ in. male thread. |
Manuals
- Technical Data Manual — Vitogas 050 ECD Series, doc 5167 444 v1.45167 444 v1.4 · 2008-01
- Technical Data Sheet — Vitogas 050 ECD-S Series
- Technical Data Manual — Vitogas 050 ECV Series, doc 5167 449 v1.35167 449 v1.3 · 2008-01
- Technical Data Manual — Vitogas 050 RS Series, rev 1.21.2 · 2004-01
Alerts documented for this model
None documented yet.
Frequently asked questions
What is the ECV-100 rated at?
100 MBH (29 kW) input, 84 MBH (25 kW) output and 83.1% AFUE, with four cast-iron sections and three burners.
How much does the ECV-100 weigh?
293 lb (133 kg) with insulation, burners and packaging, with 3.5 USG of boiler water content.
Does the ECV-100 need a chimney?
No. The ECV is the power-vent variant of the Vitogas 050, using a 3 in. vent collar rather than a chimney; the ECD and ECD-S variants are the chimney-vented models.
Questions about the Viessmann Vitogas 050 ECV-100?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Viessmann Vitogas 050 ECD-65Same series
- Viessmann Vitogas 050 ECD-80Same series
- Viessmann Vitogas 050 ECD-100Same series
- Viessmann Vitogas 050 ECD-115Same series
- Viessmann Vitogas 050 ECD-140Same series
- Viessmann Vitogas 050 ECD-155Same series
- Viessmann Vitogas 050 ECD-180Same series
- Viessmann Vitogas 050 ECD-200Same series
- Viessmann Vitogas 050 ECV-65Same series
- Viessmann Vitogas 050 ECV-80Same series
- Viessmann Vitogas 050 ECV-115Same series
- Viessmann Vitogas 050 ECV-140Same series
- Viessmann Vitogas 050 ECV-155Same series
- Viessmann Vitogas 050 ECV-180Same series
- Viessmann Vitogas 050 ECV-200Same series
- Viessmann Vitogas 050 RS-8Same series
- Viessmann Vitogas 050 RS-11Same series
- Viessmann Vitogas 050 RS-14Same series
- Vitogas 050 (ECD / ECV / RS) series hub
- Buying guide
Sources and verification
- Technical Data Manual — Vitogas 050 ECV Series, doc 5167 449 v1.3 · 5167 449 v1.3 · accessed September 9, 2026
- Viessmann Canada — Historic manuals · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.