Viessmann · Vitogas 050 (ECD / ECV / RS)
Viessmann Vitogas 050 ECV-115
The Vitogas 050 ECV-115 is the larger four-section ECV size: 115 MBH input (34 kW), 97 MBH output and 83.1% AFUE.
Key figures
- Max input
- —
- Max CSA output
- —
- AFUE
- 83.1 %
- Min input
- —
Input is gas energy consumed; output is heat delivered. Never size from input alone.
Viessmann Vitogas 050 ECV-115 in practice
The ECV-115 fires at 115 MBH (34 kW) input with 97 MBH (28 kW) output at 83.1% AFUE, sharing the four-section, three-burner chassis, 3.5 USG water content and 293 lb (133 kg) weight with the ECV-100.
The 3 in. vent collar, 20 ft maximum equivalent vent run and 50 psig maximum operating pressure are unchanged. The ECV line is documented in Viessmann Canada's historic manuals with its own technical data manual (doc 5167 449 v1.3).
Best suited to
- Existing ECV-115 installations needing printed ratings
- Residential loads between the ECV-100 and ECV-140
- Comparing the two four-section ECV sizes
Applicability and support
- Model number
- ECV-115
- Canadian availability
- historical
- Production status
- discontinued
- ROMA supplies
- Confirmed at consultation
- ROMA services
- Confirmed at consultation
- Warranty
- Not verified
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Specifications
Published specifications
Values as published by Viessmann. Units are shown with every value; notes flag conflicting sources or missing figures.
| Specification | Value | Note |
|---|---|---|
| Input | ||
| CSA input (natural gas) | 115 MBH | 34 kW, per the technical data manual |
| Output | ||
| CSA output / DOE output | 97 MBH | 28 kW |
| Efficiency | ||
| Efficiency (AFUE) | 83.1 % | Printed as 83.1% AFUE on all eight ECV sizes. |
| Venting and air | ||
| Vent pipe collar | 3 in | Maximum equivalent vent run 20 ft (6 m) with 3 in. vent pipe. |
| Physical and connections | ||
| Weight (with insulation, burners and packaging) | 293 lb | 133 kg |
| Overall width | 432 mm | Printed as 17 in |
| Overall depth | 502 mm | 19¾ in |
| Overall height | 1,030 mm | Printed as 41½ in |
| Operating limits and other | ||
| Fuel | Natural gas or propane | 3.5 in. w.c. manifold pressure NG; 10 in. w.c. propane. |
| Cast iron sections | 4 | 3 burners. |
| Boiler water content | 3.5 USG | Per the technical data manual. |
| Maximum operating pressure | 50 psig | 345 kPa. |
| Boiler supply / return | 1¼ in. male thread | Gas supply ½ in. male thread. |
Manuals
- Technical Data Manual — Vitogas 050 ECD Series, doc 5167 444 v1.45167 444 v1.4 · 2008-01
- Technical Data Sheet — Vitogas 050 ECD-S Series
- Technical Data Manual — Vitogas 050 ECV Series, doc 5167 449 v1.35167 449 v1.3 · 2008-01
- Technical Data Manual — Vitogas 050 RS Series, rev 1.21.2 · 2004-01
Alerts documented for this model
None documented yet.
Frequently asked questions
What is the ECV-115 rated at?
115 MBH (34 kW) input, 97 MBH (28 kW) output and 83.1% AFUE, with four cast-iron sections and three burners.
How does the ECV-115 differ from the ECV-100?
Only the firing rate: 115 vs 100 MBH input and 97 vs 84 MBH output, in the same chassis and weight.
Does the ECV-115 have its own manual?
Yes — the Vitogas 050 ECV technical data manual (doc 5167 449 v1.3, 01/2008) covers all eight ECV sizes and is linked on this record.
Questions about the Viessmann Vitogas 050 ECV-115?
Describe what the boiler is doing and get a straight answer about the next step.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Compare and explore
- Viessmann Vitogas 050 ECD-65Same series
- Viessmann Vitogas 050 ECD-80Same series
- Viessmann Vitogas 050 ECD-100Same series
- Viessmann Vitogas 050 ECD-115Same series
- Viessmann Vitogas 050 ECD-140Same series
- Viessmann Vitogas 050 ECD-155Same series
- Viessmann Vitogas 050 ECD-180Same series
- Viessmann Vitogas 050 ECD-200Same series
- Viessmann Vitogas 050 ECV-65Same series
- Viessmann Vitogas 050 ECV-80Same series
- Viessmann Vitogas 050 ECV-100Same series
- Viessmann Vitogas 050 ECV-140Same series
- Viessmann Vitogas 050 ECV-155Same series
- Viessmann Vitogas 050 ECV-180Same series
- Viessmann Vitogas 050 ECV-200Same series
- Viessmann Vitogas 050 RS-8Same series
- Viessmann Vitogas 050 RS-11Same series
- Viessmann Vitogas 050 RS-14Same series
- Vitogas 050 (ECD / ECV / RS) series hub
- Buying guide
Sources and verification
- Technical Data Manual — Vitogas 050 ECV Series, doc 5167 449 v1.3 · 5167 449 v1.3 · accessed September 9, 2026
- Viessmann Canada — Historic manuals · accessed September 9, 2026
Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.