Skip to content
Boilers.caby ROMA Heating & Cooling

Lochinvar · Copper-Fin (CBN/CHN)

Lochinvar Copper-Fin Atmospheric CBN360

The Copper-Fin Atmospheric CBN360 covers 180 to 360 MBH input with 295 MBH gross output and a 257 MBH AHRI net rating at 82.0% thermal efficiency — the size whose page anchors Lochinvar's current atmospheric Copper-Fin listing.

CurrentSold in Canada

Key figures

Max input
360 MBH
Max CSA output
AFUE
Min input
180 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar Copper-Fin Atmospheric CBN360 in practice

The CBN360 is the second atmospheric Copper-Fin size and the one whose model page represents the line on lochinvar.com. The I&O ratings table lists 180 to 360 MBH input, 295 MBH gross output and a 257 MBH AHRI net water rating at 82.0% thermal efficiency, with 1.2 gallons of water content; the CBA-Sub-08 submittal adds a 255 lb shipping weight and a 9" vent on a 1" gas connection.

The line's product page prints "Copper-Fin atmospheric commercial boilers deliver dependable 82% thermal efficiency" over a 315,000–500,000 BTU/hr range, with the heavy-duty gasketless heat exchanger, built-in draft diverter and 2-stage electronic temperature control as the headline features. Firing is two-stage high/low with intermittent electronic ignition (M9 standard), and venting is Category I Type B double-wall with the built-in draft diverter. The submittal prints a 10-year limited heat-exchanger warranty.

Best suited to

  • Mid-range commercial heating loads near 360 MBH
  • Replacement projects that keep a Category I Type B vent system
  • Buildings that want two-stage firing with a draft-diverter boiler

Applicability and support

Model number
CBN360
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar Copper-Fin Atmospheric CBN360 specifications
SpecificationValueNote
Input
Heating input, minimum180 MBHPer the I&O ratings table.
Heating input, maximum360 MBHPer the submittal sheet and the I&O ratings table.
Output
Gross output295 MBHGross output per the submittal sheet ratings table.
Net AHRI water rating257 MBHNet AHRI rating based on a piping and pickup allowance of 1.15, per the submittal and I&O ratings-table notes.
Efficiency
Efficiency (thermal)82 %82.0% thermal efficiency printed in the CBA-Sub-08 submittal and on the product page; no AFUE is published.
Venting and air
Vent size9"Per the submittal and I&O ratings tables.
VentingConventional negative draft (Category I) with built-in draft diverter; Type B double-wall ventThe I&O describes a conventional negative-draft system where the built-in draft diverter means no additional external draft hood is required; the product summary prints Category I, B-VENT material and -0.02 to -0.05 in. w.c. draft.
Physical and connections
Water content1.2 galPer the I&O ratings table.
Space-heating water connections2"2" NPT on 6-1/4" centers per the CBA-Sub-08 submittal.
Gas connection1"Per the submittal and I&O ratings tables.
Shipping weight255 lbShipping weight per the submittal sheet ratings table.
Dimension A29-1/2"As labeled on the CBA-Sub-08 dimension drawing; dimensions are approximate per the submittal.
Dimension B35-1/4"As labeled on the CBA-Sub-08 dimension drawing; dimensions are approximate per the submittal.
Dimension C21-1/2"As labeled on the CBA-Sub-08 dimension drawing; dimensions are approximate per the submittal.
Dimension D17-3/4"As labeled on the CBA-Sub-08 dimension drawing; dimensions are approximate per the submittal.
Operating limits and other
FiringTwo-stage (high/low fire)Two-stage intermittent electronic ignition and two-stage solid state temperature control per the CBA-Sub-08 standard features (firing code M9 standard).

Manuals

    Alerts documented for this model

    None documented yet.

    Services

    Frequently asked questions

    What are the CBN360's ratings?

    180 to 360 MBH input, 295 MBH gross output and a 257 MBH AHRI net water rating at 82.0% thermal efficiency, per the CBA-Sub-08 submittal and the I&O ratings table.

    Which page documents the CBN360?

    The CBN360 model page is the current lochinvar.com page for the atmospheric Copper-Fin line; it prints the 315,000–500,000 BTU/hr range, 82% thermal efficiency, built-in draft diverter and 2-stage electronic temperature control.

    Questions about the Lochinvar Copper-Fin Atmospheric CBN360?

    Describe what the boiler is doing and get a straight answer about the next step.

    On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

    Sources and verification

    Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

    CallEmailEstimate