- Input
- 157.5–315 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Atmospheric CBN315 is the entry size of the line: 157.5 to 315 MBH input with 258 MBH gross output and a 224 MBH AHRI net rating at 82.0% thermal efficiency, on 2" water and 3/4" gas connections with an 8" Category I vent.
Natural gasPropaneHeating-only
- Input
- 180–360 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Atmospheric CBN360 covers 180 to 360 MBH input with 295 MBH gross output and a 257 MBH AHRI net rating at 82.0% thermal efficiency — the size whose page anchors Lochinvar's current atmospheric Copper-Fin listing.
Natural gasPropaneHeating-only
- Input
- 199.5–399 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Atmospheric CBN399 runs 199.5 to 399 MBH input with 328 MBH gross output and a 285 MBH AHRI net rating at 82.0% thermal efficiency, stepping up to a 10" vent and a 1" gas connection.
Natural gasPropaneHeating-only
- Input
- 250–500 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Atmospheric CBN500 tops the atmospheric line at 250 to 500 MBH input with 410 MBH gross output and a 357 MBH AHRI net rating at 82.0% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 250–495 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN0497 opens the eight-size line at 250 to 495 MBH input with 416 MBH gross output and a 362 MBH AHRI net rating at 84% thermal efficiency, on a 6" vent.
Natural gasPropaneHeating-only
- Input
- 350–645 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN0647 steps to 350 to 645 MBH input with 542 MBH gross output and a 471 MBH AHRI net rating at 84% thermal efficiency and an 8" vent.
Natural gasPropaneHeating-only
- Input
- 350–745 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN0747 reaches 350 to 745 MBH input with 626 MBH gross output and a 544 MBH AHRI net rating at 84% thermal efficiency, closing the 2" water-connection group.
Natural gasPropaneHeating-only
- Input
- 360–985 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN0987 moves into the larger cabinet: 360 to 985 MBH input with 827 MBH gross output and a 719 MBH AHRI net rating at 84% thermal efficiency, on 2-1/2" water and 2" gas connections.
Natural gasPropaneHeating-only
- Input
- 720–1255 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN1257 covers 720 to 1,255 MBH input with 1,054 MBH gross output and a 917 MBH AHRI net rating at 84% thermal efficiency, moving to a 12" vent.
Natural gasPropaneHeating-only
- Input
- 720–1435 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN1437 reaches 720 to 1,435 MBH input with 1,205 MBH gross output and a 1,048 MBH AHRI net rating at 84% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 720–1795 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN1797 covers 720 to 1,795 MBH input with 1,508 MBH gross output and a 1,311 MBH AHRI net rating at 84% thermal efficiency, stepping up to a 14" vent.
Natural gasPropaneHeating-only
- Input
- 990–2065 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin Fan Assisted CBN2067 tops the line at 990 to 2,065 MBH input with 1,735 MBH gross output and a 1,508 MBH AHRI net rating at 84% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 250–399 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN0402 opens the line at 250 to 399 MBH input with 339 MBH gross output and a 295 MBH AHRI net rating at 85% thermal efficiency, with the SMART SYSTEM control and up to 4:1 proportional firing.
Natural gasPropaneHeating-only
- Input
- 250–500 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN0502 covers 250 to 500 MBH input with 425 MBH gross output and a 370 MBH AHRI net rating at 85% thermal efficiency on a 6" vent.
Natural gasPropaneHeating-only
- Input
- 250–650 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN0652 covers 250 to 650 MBH input with 553 MBH gross output and a 481 MBH AHRI net rating at 85% thermal efficiency, moving to an 8" vent and air inlet.
Natural gasPropaneHeating-only
- Input
- 250–750 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN0752 reaches 250 to 750 MBH input with 638 MBH gross output and a 555 MBH AHRI net rating at 85% thermal efficiency, closing the 2" water-connection group.
Natural gasPropaneHeating-only
- Input
- 360–990 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN0992 moves to the larger cabinet and 2-1/2" water connections: 360 to 990 MBH input with 842 MBH gross output and a 732 MBH AHRI net rating at 85% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 360–1260 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN1262 covers 360 to 1,260 MBH input with 1,071 MBH gross output and a 931 MBH AHRI net rating at 85% thermal efficiency on a 12" vent.
Natural gasPropaneHeating-only
- Input
- 360–1440 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN1442 reaches 360 to 1,440 MBH input with 1,224 MBH gross output and a 1,064 MBH AHRI net rating at 85% thermal efficiency.
Natural gasPropaneHeating-only
- Input
- 360–1800 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN1802 covers 360 to 1,800 MBH input with 1,530 MBH gross output and a 1,330 MBH AHRI net rating at 85% thermal efficiency, with a 14" vent and 12" air inlet.
Natural gasPropaneHeating-only
- Input
- 630–2070 MBH
- Output (max)
- —
- AFUE
- —
The Copper-Fin II CHN2072 tops the line at 630 to 2,070 MBH input with 1,760 MBH gross output and a 1,530 MBH AHRI net rating at 85% thermal efficiency.
Natural gasPropaneHeating-only