Skip to content
Boilers.caby ROMA Heating & Cooling

Lochinvar · Copper-Fin (CBN/CHN)

Lochinvar Copper-Fin Fan Assisted CBN1437

The Copper-Fin Fan Assisted CBN1437 reaches 720 to 1,435 MBH input with 1,205 MBH gross output and a 1,048 MBH AHRI net rating at 84% thermal efficiency.

CurrentSold in Canada

Key figures

Max input
1,435 MBH
Max CSA output
—
AFUE
—
Min input
720 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar Copper-Fin Fan Assisted CBN1437 in practice

The CBN1437 is the sixth of the eight fan-assisted sizes: 720 to 1,435 MBH input, 1,205 MBH gross output and a 1,048 MBH AHRI net water rating at 84% thermal efficiency, with 3.7 gallons of water content. The CB-Sub-14 submittal prints a 1,050 lb shipping weight and the same 12" vent as the CBN1257, on 2-1/2" NPT water and 2" gas connections.

It uses the larger cabinet with a 68-3/4" B dimension and the 36" A / 33-1/2" C / 15-3/4" D group. The fan-assisted Category I design carries the sealed combustion chamber, hot surface ignition, two-stage electronic temperature control, combustion air filter and 8.4 A total fan/control draw, with a 10-year limited heat-exchanger warranty in the submittal.

Best suited to

  • Loads between the 1,255 and 1,795 MBH fan-assisted sizes
  • Plants that need more than 1,000 MBH of AHRI net output
  • Replacement projects keeping the 12" vent and 2-1/2" water connections

Applicability and support

Model number
CBN1437
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar Copper-Fin Fan Assisted CBN1437 specifications
SpecificationValueNote
Input
Heating input, minimum720 MBHPer the I&O ratings table.
Heating input, maximum1,435 MBHPer the submittal sheet and the I&O ratings table.
Output
Gross output1,205 MBHGross output per the submittal sheet ratings table.
Net AHRI water rating1,048 MBHNet AHRI rating based on a piping and pickup allowance of 1.15, per the submittal and I&O ratings-table notes.
Efficiency
Efficiency (thermal)84 %84% thermal efficiency printed in the CB-Sub-14 submittal and on the product page; no AFUE is published.
Venting and air
Vent size12"Per the submittal and I&O ratings tables.
VentingFan-assisted Category I; conventional negative draft or outdoor installation ventingThe CBX I&O calls it a "fan-assisted Category 1 unit" with two venting options (conventional negative-draft vertical or outdoor installation); the sealed combustion chamber and combustion air filter are standard.
Physical and connections
Water content3.7 galPer the I&O ratings table.
Space-heating water connections2-1/2"2-1/2" NPT on 11-1/4" centers per the CB-Sub-14 submittal.
Gas connection2"Per the submittal and I&O ratings tables.
Shipping weight1,050 lbShipping weight per the submittal sheet ratings table.
Dimension A36"As labeled on the CB-Sub-14 dimension drawing; dimensions are approximate per the submittal.
Dimension B68-3/4"As labeled on the CB-Sub-14 dimension drawing; dimensions are approximate per the submittal.
Dimension C33-1/2"As labeled on the CB-Sub-14 dimension drawing; dimensions are approximate per the submittal.
Dimension D15-3/4"As labeled on the CB-Sub-14 dimension drawing; dimensions are approximate per the submittal.
Dimension E10-1/2"As labeled on the CB-Sub-14 dimension drawing; dimensions are approximate per the submittal.
Dimension F10-1/2"As labeled on the CB-Sub-14 dimension drawing; dimensions are approximate per the submittal.
Dimension G33-3/4"As labeled on the CB-Sub-14 dimension drawing; dimensions are approximate per the submittal.
Operating limits and other
FiringTwo-stage (high/low fire)Two-stage electronic temperature control with hot surface ignition per the CB-Sub-14 standard features (M9 hot surface ignition with electronic supervision standard).

Manuals

    Alerts documented for this model

    None documented yet.

    Services

    Frequently asked questions

    What are the CBN1437's ratings?

    720 to 1,435 MBH input, 1,205 MBH gross output and a 1,048 MBH AHRI net water rating at 84% thermal efficiency, per the CB-Sub-14 submittal and the I&O ratings table.

    Does the CBN1437 share the CBN1257's connections?

    Yes. Both use 2-1/2" NPT water connections on 11-1/4" centers, a 2" gas connection and a 12" vent per the CB-Sub-14 submittal.

    Questions about the Lochinvar Copper-Fin Fan Assisted CBN1437?

    Describe what the boiler is doing and get a straight answer about the next step.

    On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

    Sources and verification

    Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

    CallEmailEstimate