Skip to content
Boilers.caby ROMA Heating & Cooling

Lochinvar · Copper-Fin (CBN/CHN)

Lochinvar Copper-Fin II CHN1262

The Copper-Fin II CHN1262 covers 360 to 1,260 MBH input with 1,071 MBH gross output and a 931 MBH AHRI net rating at 85% thermal efficiency on a 12" vent.

CurrentSold in Canada

Key figures

Max input
1,260 MBH
Max CSA output
—
AFUE
—
Min input
360 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar Copper-Fin II CHN1262 in practice

The CHN1262 crosses 1,000 MBH of gross output: the CHX I&O ratings table lists 360 to 1,260 MBH input, 1,071 MBH gross output and a 931 MBH AHRI net water rating at 85% thermal efficiency, with 3.5 gallons of water content. The CHE-Sub-11 submittal prints an 863 lb shipping weight and 12" vent and air-inlet sizes on 2-1/2" NPT water and a 2" gas connection.

It keeps the 36" A / 33-1/2" C cabinet and grows the B dimension to 58-1/2". The full Copper-Fin II control package — SMART SYSTEM with 8-boiler cascade, front-end loading with Crest or Knight, 0-10 VDC rate output, BMS integration — and the Category I/IV venting options carry over, with 85% AHRI-certified thermal efficiency, a 10-year limited warranty and 1-year parts printed in the submittal.

Best suited to

  • Commercial loads above 1,000 MBH of gross output
  • Plants with a 12" flue and 2-1/2" water piping
  • Cascades replacing two smaller boilers with one larger CHN1262

Applicability and support

Model number
CHN1262
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar Copper-Fin II CHN1262 specifications
SpecificationValueNote
Input
Heating input, minimum360 MBHPer the I&O ratings table.
Heating input, maximum1,260 MBHPer the submittal sheet and the I&O ratings table.
Output
Gross output1,071 MBHGross output per the submittal sheet ratings table.
Net AHRI water rating931 MBHNet AHRI rating based on a piping and pickup allowance of 1.15, per the submittal and I&O ratings-table notes.
Efficiency
Efficiency (thermal)85 %85% thermal efficiency (AHRI certified) printed in the CHE-Sub-11 submittal and on the product page; no AFUE is published.
Venting and air
Vent size12"Per the submittal and I&O ratings tables.
Air inlet size12"Per the CHE-Sub-11 submittal ratings table.
VentingCategory I (Type B double-wall) or Category IV (AL29-4C stainless steel); vertical or horizontalPer the CHE-Sub-11 standard features and the CHX I&O venting section; DirectAire and powered sidewall options are listed in the submittal.
Physical and connections
Water content3.5 galPer the I&O ratings table.
Space-heating water connections2-1/2"2-1/2" NPT on 11-1/4" centers per the CHE-Sub-11 submittal.
Gas connection2"Per the submittal and I&O ratings tables.
Shipping weight863 lbShipping weight per the submittal sheet ratings table.
Dimension A36"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension B58-1/2"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension C33-1/2"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension D15-3/4"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension E10-1/2"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension F9-1/2"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension G33-3/4"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Dimension H8-3/4"As labeled on the CHE-Sub-11 dimension drawing; dimensions are approximate per the submittal.
Operating limits and other
FiringProportional, up to 4:1 turndownProportional firing up to 4:1 turndown per the CHE-Sub-11 standard features; the CHX I&O ratings table prints minimum inputs of 250/360/630 MBH by size.

Manuals

    Alerts documented for this model

    None documented yet.

    Services

    Frequently asked questions

    What are the CHN1262's ratings?

    360 to 1,260 MBH input, 1,071 MBH gross output and a 931 MBH AHRI net water rating at 85% thermal efficiency, per the CHE-Sub-11 submittal and the CHX I&O ratings table.

    What vent size does the CHN1262 use?

    12" vent and 12" air inlet per the CHE-Sub-11 submittal, in Category I Type B or Category IV AL29-4C stainless steel.

    Questions about the Lochinvar Copper-Fin II CHN1262?

    Describe what the boiler is doing and get a straight answer about the next step.

    On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

    Sources and verification

    Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

    CallEmailEstimate