Skip to content
Boilers.caby ROMA Heating & Cooling

IBC Technologies · Series

IBC Technologies Superflow SFC-1 Combi

The IBC Superflow SFC-1 is a wall-hung condensing combi boiler sold in Canada as the SFC 99-1, SFC 125-1 and SFC 199-1, combining space heating with on-demand domestic hot water in one cast-aluminium heat exchanger with copper waterways.

Current seriesSold in CanadaNatural gasPropaneresidential

Series facts

Type
combi
Efficiency
95% AFUE
Fuel
Natural gas or propane; IBC states a fuel conversion kit is included with each unit.
Venting
2" or 3" Schedule 40 PVC, CPVC or polypropylene (PPs) direct-vent; 2" to 65 equivalent feet and 3" to 120 equivalent feet per side on the Canadian SFC-1 models.
Models documented
3
Warranty
Not verified

IBC lists 96% AFUE for the SFC 99-1 and 95% for the SFC 125-1 and SFC 199-1.

About the Superflow SFC-1 Combi

The SFC-1 does both jobs in a single heat exchanger: two independent copper waterways cast into an aluminium block condense the flue gases whether the unit is heating rooms or heating tap water. There is no secondary plate heat exchanger and no three-way valve, and IBC counts five moving parts in total (fan, pump, bypass valve, gas valve and damper). The SFC 199-1 also carries a built-in bypass valve to steady DHW temperatures.

A useful quirk of the SFC line is that the space-heating input is capped below the DHW input. The SFC 125-1 fires to 99 MBH for heating but to 125 MBH for hot water, and the SFC 199-1 fires to 125 MBH for heating but to 199 MBH for hot water. A home whose heating load is met at 99 MBH can still get the larger DHW reserve of a 199.

Venting is 2" or 3" Schedule 40 PVC, CPVC or PPs, which suits retrofit jobs where an old chimney is not reusable. The numeric touch-panel control shows fault codes such as F004 (no flame during four ignition trials) rather than text messages, so Boilers.ca documents the full code table against the manual version.

Highlights

  • Space heating and DHW from one heat exchanger (no plate heat exchanger or three-way valve)
  • DHW input exceeds heating input: up to 199 MBH on the SFC 199-1
  • 2" or 3" PVC / CPVC / PPs venting, direct-vent only
  • 96% AFUE on the SFC 99-1; 95% on the SFC 125-1 and SFC 199-1
  • Wireless cascade of up to eight units on the SFC 199-1
  • Numeric-display control with documented F-code fault table

Models

Superflow SFC-1 Combi models

One canonical page per model with input, output and efficiency kept separate.

IBC Technologies

IBC SFC 99-1 Superflow

CurrentSold in Canada
Input
15.5–99 MBH
Output (max)
89 MBH
AFUE
96 %

The IBC SFC 99-1 is the smallest Superflow SFC combi boiler: up to 99 MBH input for space heating and DHW, 96% AFUE, wall-hung, with 2" or 3" PVC/CPVC/PPs venting. It is a fit for townhouses and smaller homes wanting one appliance for heat and hot water.

Natural gasPropaneCombi

IBC Technologies

IBC SFC 125-1 Superflow

CurrentSold in Canada
Input
16.5–99 MBH
Output (max)
89 MBH
AFUE
95 %

The IBC SFC 125-1 Superflow is a wall-hung condensing combi boiler rated 95% AFUE: up to 99 MBH for space heating and 125 MBH for domestic hot water, with 3.2 GPM continuous DHW delivery at a 67°F rise.

Natural gasPropaneCombi

IBC Technologies

IBC SFC 199-1 Superflow

CurrentSold in Canada
Input
28.5–125 MBH
Output (max)
111 MBH
AFUE
95 %

The IBC SFC 199-1 is the largest Superflow combi: 95% AFUE, up to 125 MBH for space heating and 199 MBH for hot water, 5 GPM continuous DHW at a 67°F rise, with wireless cascade of up to eight units on the SFC 199-1.

Natural gasPropaneCombi

Compare models in this series

Comparison of IBC SFC 99-1 Superflow and IBC SFC 125-1 Superflow and IBC SFC 199-1 Superflow
SpecificationIBC SFC 99-1 SuperflowIBC SFC 125-1 SuperflowIBC SFC 199-1 Superflow
Heating input, minimum15.5 MBH16.5 MBH28.5 MBH
Heating input, maximum99 MBH99 MBH125 MBH
CSA output, maximum89 MBH89 MBH111 MBH
Efficiency (AFUE)96 %95 %95 %
turndown———
Max. equivalent vent length, 3"120 ft120 ft120 ft
Max. equivalent vent length, 2"65 ft65 ft65 ft
Weight (empty)85 lb85 lb84 lb

Read the full comparison: IBC SFC 99-1 vs SFC 125-1 →

Read the full comparison: IBC SFC 125-1 vs SFC 199-1 →

Read the full comparison: IBC SFC 99-1 Superflow vs IBC SFC 199-1 Superflow →

Read the full comparison: IBC SFC 99-1 Superflow vs NTI Trinity FTVN110C →

Read the full comparison: IBC SFC 199-1 Superflow vs NTI Trinity TRX199C →

Read the full comparison: IBC SFC 199-1 Superflow vs Lochinvar Noble NKC199 →

Error codes and alerts

Superflow SFC-1 Combi alerts

  • F000numeric-display touch panel control
  • F001numeric-display touch panel control
  • F002numeric-display touch panel control
  • F003numeric-display touch panel control
  • F004numeric-display touch panel control
  • F005numeric-display touch panel control
  • F006numeric-display touch panel control
  • F007numeric-display touch panel control
  • F008numeric-display touch panel control
  • F009numeric-display touch panel control
  • F010numeric-display touch panel control
  • F011numeric-display touch panel control
  • F012numeric-display touch panel control
  • F013numeric-display touch panel control
  • F014numeric-display touch panel control
  • F015numeric-display touch panel control
  • F016numeric-display touch panel control
  • F017numeric-display touch panel control
  • F018numeric-display touch panel control
  • F019numeric-display touch panel control
  • F021numeric-display touch panel control
  • F027numeric-display touch panel control
  • F028numeric-display touch panel control
  • F029numeric-display touch panel control
  • F031numeric-display touch panel control
  • F040numeric-display touch panel control
  • F041numeric-display touch panel control
  • F042numeric-display touch panel control
  • --numeric-display touch panel control
  • Enumeric-display touch panel control
  • n030numeric-display touch panel control
  • n040numeric-display touch panel control
  • n041numeric-display touch panel control
  • n120numeric-display touch panel control
  • n121numeric-display touch panel control
  • n122numeric-display touch panel control
  • n150numeric-display touch panel control
  • n151numeric-display touch panel control
  • n152numeric-display touch panel control
  • n201numeric-display touch panel control
  • n202numeric-display touch panel control
  • n245numeric-display touch panel control

Manuals

Official documents

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Frequently asked questions

Is the SFC-1 a boiler or a water heater?

It is a combi boiler: one appliance provides space heating through its central-heating coil and on-demand domestic hot water through a second integrated coil.

Why is the heating input lower than the DHW input on the SFC-1?

IBC rates the SFC 125-1 to 99 MBH and the SFC 199-1 to 125 MBH for space heating, while DHW input reaches 125 or 199 MBH. That is how the manufacturer publishes the CSA input figures on its Canadian pages and in the installation manual.

What venting does the SFC-1 use?

2" or 3" Schedule 40 PVC, CPVC or PPs, direct-vent only, up to 65 equivalent feet in 2" or 120 equivalent feet in 3" per side on the Canadian models.

Talk to a boiler technician

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate