Lochinvar Crest Too Many Resets - Try Later — Too Many Manual Resets Occurred during a 15 Minute Period
Too Many Resets - Try Later
Too many manual resets occurred during a 15 minute period. Too many manual resets have occurred during a 15 minute period, so wait 15 minutes and try again, or turn power off to the unit, wait 30 seconds, and turn the power back on.
Applies to
This fault code is displayed by the Crest control (text faults) on Crest with Hellcat models (FCB1000 through FCB6000), as documented in Crest with Hellcat (FCB) Service Manual, 100343237 Rev D — Table 3G fault codes (100343237 Rev D). Codes can differ between controller generations, so always check the manual that matches your unit.
- Lochinvar Crest (FB / Hellcat FCB)
- Lochinvar Crest FBN0751
- Lochinvar Crest FBN1001
- Lochinvar Crest FBN1251
- Lochinvar Crest FBN1501
- Lochinvar Crest FBN1751
- Lochinvar Crest FBN2001
- Lochinvar Crest FBN2501
- Lochinvar Crest FBN3001
- Lochinvar Crest FBN3501
- Lochinvar Crest FBN4001
- Lochinvar Crest FBN5001
- Lochinvar Crest FBN6001
- Lochinvar Crest FCB1000
- Lochinvar Crest FCB1500
- Lochinvar Crest FCB2000
- Lochinvar Crest FCB2500
- Lochinvar Crest FCB3000
- Lochinvar Crest FCB4000
- Lochinvar Crest FCB5000
- Lochinvar Crest FCB6000
Controller: Crest control (text faults). Source manual: 100343237 Rev D (2025-07).
Why a code is not a diagnosis
The code reports the condition the control detected; the underlying cause must be confirmed on site by a licensed technician using the manufacturer's procedure.
Safe things to observe
- Note the exact code, when it appears and what the appliance was doing.
- If the appliance has stopped, call a technician rather than repeatedly restarting it.
- If you smell gas, stop, go outside and call your gas utility's emergency line or 911 before anything else.
Do not
- Do not ignore a code that returns after a reset.
How professional service helps
- A licensed technician diagnoses the cause with the manufacturer's test procedure.
- Combustion and safety devices are verified with an analyser and the manufacturer's procedure after any repair.
Where ROMA provides on-site service
On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.
Frequently asked questions
Can I clear this code myself?
Clearing a code without fixing its cause usually just brings it back. Note the code, check the safe items on this page, then call a licensed technician. If your appliance manual describes a user reset for this exact code and it stays away, no call may be needed.
Boiler locked out? Call with the alert text ready.
The brand, model and this alert are passed along when you request service online, so the technician arrives prepared.
On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.
Sources and verification
- Crest with Hellcat (FCB) Service Manual, 100343237 Rev D — Table 3G fault codes · 100343237 Rev D · accessed September 7, 2026
Facts checked September 7, 2026. Last updated September 7, 2026. Technical reviewer: not yet assigned.