Lochinvar · Crest (FB / Hellcat FCB)

Lochinvar Crest FCB1500

The Crest with Hellcat FCB1500 fires 60 to 1500 MBH with 1443 MBH gross output and a 1252 MBH AHRI net rating, stepping the Hellcat line to 4" pipe and 8" air and vent.

CurrentSold in Canada

Key figures

Max input
1,500 MBH
Max CSA output
AFUE
Min input
60 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar Crest FCB1500 in practice

The FCB1500 is the second rung of the Crest with Hellcat range: the I&O ratings table lists 60 to 1500 MBH input with 1443 MBH gross output and a 1252 MBH AHRI net water rating, matching the Crest FB1501 ratings row. It is the first FCB size on 4" pipe outlet and inlet, with the gas inlet at 1-1/2" and air and vent both 8".

Water content is 94 gallons and weight with water 2,307 lb per the ratings table. The Hellcat combustion system with RealTime O2 Trim and the 10" capacitive touchscreen control distinguish the line, and venting is room air/direct vent or common vent in stainless steel, polypropylene, PVC or CPVC to 150 equivalent feet per the page feature list.

Best suited to

  • Commercial loads between 1,000 and 1,500 MBH on the Hellcat platform
  • Projects stepping to 4" boiler piping with an 8" air/vent envelope
  • Plants that want the Hellcat's O2 trim across a 1.5 million BTU/hr ceiling

Applicability and support

Model number
FCB1500
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar Crest FCB1500 specifications
SpecificationValueNote
Input
Heating input, minimum60 MBHPer the I&O ratings table.
Heating input, maximum1,500 MBHPer the I&O ratings table.
Output
Gross output1,443 MBHPer the I&O ratings table.
Net AHRI water rating1,252 MBHPer the I&O ratings table.
Venting and air
Air size8"Per the I&O ratings table.
Vent size8"Per the I&O ratings table.
VentingCategory IV sealed combustion; room air/direct vent/common vent in stainless steel, polypropylene, PVC or CPVCUp to 150 equivalent feet per the Crest with Hellcat product-page feature list.
Physical and connections
Water content94 galPer the I&O ratings table.
Pipe outlet connection4"Per the I&O ratings table.
Pipe inlet connection4"Per the I&O ratings table.
Gas connection1-1/2"Per the I&O ratings table.
Weight with water2,307 lbPer the I&O ratings table.

Frequently asked questions

What are the FCB1500's ratings?

60 to 1500 MBH of input with 1443 MBH gross output and a 1252 MBH AHRI net water rating per the I&O ratings table.

What connections does the FCB1500 use?

4" pipe outlet and inlet, a 1-1/2" gas inlet and 8" air and vent sizes, with a 94-gallon water content and 2,307 lb weight with water per the ratings table.

Questions about the Lochinvar Crest FCB1500?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate