Lochinvar Crest FBN1251

The Crest FBN1251 fires 62.5 to 1250 MBH with 1203 MBH gross output and a 1043 MBH AHRI net rating at 20:1 turndown, stepping the gas inlet to 1-1/2" and the vent to 8".

CurrentSold in Canada

Key figures

Max input
1,250 MBH
Max CSA output
AFUE
Min input
62.5 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar Crest FBN1251 in practice

The FBN1251 carries the Crest FB line past the million-BTU mark: the I&O ratings table lists 62.5 to 1250 MBH input with 1203 MBH gross output and a 1043 MBH AHRI net water rating, at 20:1 turndown per the manual (matching the 62.5 MBH minimum). Its 87-gallon water content keeps the 3" pipe outlet and inlet of the smaller sizes.

The 1251 is the first Crest size whose vent steps to 8" (air stays 6"), and the gas inlet grows to 1-1/2". Venting is in stainless steel, polypropylene, PVC or CPVC to 100 equivalent feet per the page feature list, and weight with water is 1,975 lb per the ratings table. The family platform — wave fire-tube heat exchanger, SMART TOUCH control with CON·X·US — carries through, with the 10-year heat exchanger warranty printed on the family product page.

Best suited to

  • Commercial loads between 1,000 and 1,250 MBH on a design day
  • Projects stepping to 1-1/2" gas supply at the boiler
  • Systems planned around an 8" vent with 6" air intake

Applicability and support

Model number
FBN1251
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar Crest FBN1251 specifications
SpecificationValueNote
Input
Heating input, minimum62.5 MBHPer the I&O ratings table.
Heating input, maximum1,250 MBHPer the I&O ratings table.
Output
Gross output1,203 MBHPer the I&O ratings table.
Net AHRI water rating1,043 MBHPer the I&O ratings table.
Venting and air
Air size6"Per the I&O ratings table.
Vent size8"Per the I&O ratings table.
VentingCategory IV sealed combustion; stainless steel, polypropylene, PVC or CPVC ventingUp to 100 equivalent feet per the Crest product-page feature list.
Physical and connections
Water content87 galPer the I&O ratings table.
Pipe outlet connection3"Per the I&O ratings table.
Pipe inlet connection3"Per the I&O ratings table.
Gas connection1-1/2"Per the I&O ratings table.
Weight with water1,975 lbPer the I&O ratings table.

Frequently asked questions

What are the FBN1251's ratings?

62.5 to 1250 MBH of input with 1203 MBH gross output and a 1043 MBH AHRI net water rating per the I&O ratings table, at 20:1 turndown.

What changes at the FBN1251 versus the FBN1001?

Maximum input rises from 999 to 1250 MBH, the gas inlet steps from 1-1/4" to 1-1/2", the vent from 6" to 8", and water content from 77 to 87 gallons; the pipe connections stay 3".

Questions about the Lochinvar Crest FBN1251?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate