Lochinvar Crest FBN4001

The Crest FBN4001 fires 333.3 to 3999 MBH with 3843 MBH gross output and a 3342 MBH AHRI net rating at 12:1 turndown, stepping air and vent to 12" with a 2-1/2" gas inlet.

CurrentSold in Canada

Key figures

Max input
3,999 MBH
Max CSA output
AFUE
Min input
333.3 MBH
Natural gasPropaneHeating-onlycommercial

Input is gas energy consumed; output is heat delivered. Never size from input alone.

Lochinvar Crest FBN4001 in practice

The FBN4001 is the first Crest FB size whose turndown tightens to 12:1 per the I&O: the ratings table lists 333.3 to 3999 MBH input with 3843 MBH gross output and a 3342 MBH AHRI net water rating. Water content is 201 gallons on the 4" pipe outlet and inlet, with the gas inlet stepping to 2-1/2" and air and vent both growing to 12".

The wave fire-tube boiler carries the SMART TOUCH control with CON·X·US and vents in stainless steel, polypropylene, PVC or CPVC to 100 equivalent feet per the page feature list. Weight with water reaches 5,200 lb per the ratings table — the first size past the 2-tonne mark — and the family page prints the 10-year heat exchanger warranty.

Best suited to

  • Central plants whose load approaches 4.0 million BTU/hr
  • Projects planned around 12" air and vent openings
  • Designs that accept the 333.3 MBH minimum fire at 12:1 turndown

Applicability and support

Model number
FBN4001
Canadian availability
available
Production status
current
ROMA supplies
Confirmed at consultation
ROMA services
Confirmed at consultation
Warranty
Series terms

Where ROMA provides on-site service

On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

See all service areas

Specifications

Published specifications

Values as published by Lochinvar. Units are shown with every value; notes flag conflicting sources or missing figures.

Lochinvar Crest FBN4001 specifications
SpecificationValueNote
Input
Heating input, minimum333.3 MBHPer the I&O ratings table.
Heating input, maximum3,999 MBHPer the I&O ratings table.
Output
Gross output3,843 MBHPer the I&O ratings table.
Net AHRI water rating3,342 MBHPer the I&O ratings table.
Venting and air
Air size12"Per the I&O ratings table.
Vent size12"Per the I&O ratings table.
VentingCategory IV sealed combustion; stainless steel, polypropylene, PVC or CPVC ventingUp to 100 equivalent feet per the Crest product-page feature list.
Physical and connections
Water content201 galPer the I&O ratings table.
Pipe outlet connection4"Per the I&O ratings table.
Pipe inlet connection4"Per the I&O ratings table.
Gas connection2-1/2"Per the I&O ratings table.
Weight with water5,200 lbPer the I&O ratings table.

Frequently asked questions

What are the FBN4001's ratings?

333.3 to 3999 MBH of input with 3843 MBH gross output and a 3342 MBH AHRI net water rating per the I&O ratings table, at 12:1 turndown.

How does turndown change at the FBN4001?

The I&O assigns 12:1 turndown to the 4001 (against 20:1 on the 2501-3501), which matches the 333.3 MBH minimum input against the 3999 MBH maximum.

Questions about the Lochinvar Crest FBN4001?

Describe what the boiler is doing and get a straight answer about the next step.

On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

Sources and verification

Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

CallEmailEstimate