Skip to content
Boilers.caby ROMA Heating & Cooling

Lochinvar · Series

Lochinvar Crest (FB / Hellcat FCB)

The Crest is Lochinvar's large commercial condensing fire-tube line in two families: the Crest FB(N,L)0751-6001 boilers (750,000 to 6.0 million BTU/hr, wave fire-tube design) and the Crest with Hellcat FCB1000-6000 boilers with RealTime O2 Trim combustion.

Current seriesSold in CanadaNatural gasPropanecommercial

Series facts

Type
condensing
Efficiency
Unknown
Fuel
Lochinvar prints the model codes with a fuel letter — "N" for natural gas and "L" for propane — on the ratings plates and in the I&O ratings tables (KBX0400(N,L) through KBX1000(N,L), FTX400(N,L) through FTX1000(N,L), FB(N,L)0751-FB(N,L)6001 and FCB1000(N,L)-FCB6000(N,L)); a separate FBD dual-fuel variant exists in the Crest FB line.
Venting
Category IV sealed combustion. Crest FB product-page literature lists stainless steel, polypropylene, PVC and CPVC vent materials with up to 100 equivalent feet of venting per the page feature list, while the Crest with Hellcat FCB4000N page lists the vent type as "Room Air/Direct Vent/ Common Vent" with the same materials and up to 150 equivalent feet per the page feature list.
Models documented
20

About the Crest (FB / Hellcat FCB)

The Crest is Lochinvar's commercial condensing fire-tube boiler family above the FTXL, listed on the current commercial boilers page as "Crest® Boiler with Hellcat Technology" and "Crest®". The Crest FB(N,L)0751-FB(N,L)6001 covers twelve sizes from 750,000 to 6.0 million BTU/hr with Lochinvar's exclusive wave fire-tube design, an 8" LCD touchscreen, the SMART TOUCH control with CON·X·US and a RealTime O2 Feedback option; the FBN1001 page headlines 96.2% thermal efficiency with an ENERGY STAR rating, an ASME H stamp and a 10-year heat exchanger warranty. Lochinvar's product codes split natural gas (N), propane (L) and an FBD dual-fuel variant; no "FBK" code appears anywhere on lochinvar.com (checked against the product sitemap, product pages and manuals), so Boilers.ca uses the official FB family codes only. Turndown per the I&O (Rev BA) is 15:1 on the 0751, 20:1 on the 1001/1251 and 2501-3501, 25:1 on the 1501-2001, 12:1 on the 4001 and 10:1 on the 5001-6001, and standard builds are rated 0-4,500 ft (1.4% derate per 1,000 ft) with high-altitude builds for 0751-2001 to 12,000 ft and 2501-5001/6001 to 5,500 ft.

The Crest with Hellcat (FCB1000(N,L)-FCB6000(N,L)) shares the wave fire-tube boiler platform with the Hellcat combustion system: a full-color 10" capacitive touchscreen, RealTime O2 Trim combustion that uses feedforward and feedback data to hold a targeted O2 range, and up to 150 equivalent feet of venting. The I&O (Rev U) rating table for Models 1000-6000 is reproduced on each FCB model page here; the FCB4000N page prints a 96.0% thermal efficiency headline (96% spec block), 20:1 turndown for the FCB2500-6000 sizes per the page copy, an ASME H stamp, voltages to 480 and the same 10-year heat exchanger warranty. Lochinvar's Canada English pages are identical to the United States pages for both lines. No error-code scope is wired for Crest in this batch; the current Hellcat-generation fault set is documented in the Rev D Hellcat service manual.

Highlights

  • Two commercial condensing lines: Crest FB(N,L)0751-6001 and Crest with Hellcat FCB1000-6000
  • Wave fire-tube design from 750,000 to 6.0 million BTU/hr (FB) and 999,000 to 6.0 million (FCB)
  • FB turndown 15:1 to 10:1 by size per the I&O; FCB2500-6000 at 20:1 per the page copy
  • SMART TOUCH control with CON·X·US; RealTime O2 Feedback (FB) / O2 Trim (Hellcat)
  • Venting to 100 equivalent feet (FB) or 150 (Hellcat) in stainless, polypropylene, PVC or CPVC
  • 10-yr heat exchanger and 1-yr parts warranty printed on the product pages

The Crest FBN1001 and Crest with Hellcat FCB4000N product pages both print a 10-year limited heat exchanger warranty and a 1-year limited parts warranty.

Models

Crest (FB / Hellcat FCB) models

One canonical page per model with input, output and efficiency kept separate.

CurrentSold in Canada
Input
50–750 MBH
Output (max)
—
AFUE
—

The Crest FBN0751 opens the Crest FB line at 50 to 750 MBH input with 722 MBH gross output and a 626 MBH AHRI net rating, on 3" pipe connections with 6" air and vent — 15:1 turndown.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
50–999 MBH
Output (max)
—
AFUE
—

The Crest FBN1001 fires 50 to 999 MBH with 961 MBH gross output and an 834 MBH AHRI net rating — the 96.2% thermal efficiency model whose page opens the Crest FB line, at 20:1 turndown.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
62.5–1250 MBH
Output (max)
—
AFUE
—

The Crest FBN1251 fires 62.5 to 1250 MBH with 1203 MBH gross output and a 1043 MBH AHRI net rating at 20:1 turndown, stepping the gas inlet to 1-1/2" and the vent to 8".

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
60–1500 MBH
Output (max)
—
AFUE
—

The Crest FBN1501 fires 60 to 1500 MBH with 1443 MBH gross output and a 1252 MBH AHRI net rating at 25:1 turndown, stepping the Crest to 4" pipe and 8" air and vent.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
70–1750 MBH
Output (max)
—
AFUE
—

The Crest FBN1751 fires 70 to 1750 MBH with 1684 MBH gross output and a 1461 MBH AHRI net rating at 25:1 turndown, keeping 4" pipe and 8" air and vent sizes.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
80–1999 MBH
Output (max)
—
AFUE
—

The Crest FBN2001 fires 80 to 1999 MBH with 1923 MBH gross output and a 1699 MBH AHRI net rating at 25:1 turndown, closing the 25:1 band of the FB line.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
125–2500 MBH
Output (max)
—
AFUE
—

The Crest FBN2501 fires 125 to 2500 MBH with 2400 MBH gross output and a 2087 MBH AHRI net rating at 20:1 turndown, stepping the gas inlet to 2" with a 9" vent.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
150–3000 MBH
Output (max)
—
AFUE
—

The Crest FBN3001 fires 150 to 3000 MBH with 2883 MBH gross output and a 2507 MBH AHRI net rating at 20:1 turndown, stepping air and vent to 10" at a 3.0 million BTU/hr ceiling.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
175–3500 MBH
Output (max)
—
AFUE
—

The Crest FBN3501 fires 175 to 3500 MBH with 3364 MBH gross output and a 2925 MBH AHRI net rating at 20:1 turndown, with a 202-gallon water content on 4" pipe.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
333.3–3999 MBH
Output (max)
—
AFUE
—

The Crest FBN4001 fires 333.3 to 3999 MBH with 3843 MBH gross output and a 3342 MBH AHRI net rating at 12:1 turndown, stepping air and vent to 12" with a 2-1/2" gas inlet.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
499.9–4999 MBH
Output (max)
—
AFUE
—

The Crest FBN5001 fires 499.9 to 4999 MBH with 4804 MBH gross output and a 4177 MBH AHRI net rating at 10:1 turndown, stepping the Crest to 6" pipe and 14" air and vent.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
600–6000 MBH
Output (max)
—
AFUE
—

The Crest FBN6001 tops the Crest FB line at 600 to 6000 MBH input with 5766 MBH gross output and a 5014 MBH AHRI net rating at 10:1 turndown, on 6" pipe with a 3" gas inlet.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
50–999 MBH
Output (max)
—
AFUE
—

The Crest with Hellcat FCB1000 opens the FCB line at 50 to 999 MBH input with 961 MBH gross output and an 834 MBH AHRI net rating, on 3" pipe with 6" air and vent.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
60–1500 MBH
Output (max)
—
AFUE
—

The Crest with Hellcat FCB1500 fires 60 to 1500 MBH with 1443 MBH gross output and a 1252 MBH AHRI net rating, stepping the Hellcat line to 4" pipe and 8" air and vent.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
80–1999 MBH
Output (max)
—
AFUE
—

The Crest with Hellcat FCB2000 fires 80 to 1999 MBH with 1923 MBH gross output and a 1699 MBH AHRI net rating, keeping 4" pipe and 8" air and vent at the top of the small FCB sizes.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
125–2500 MBH
Output (max)
—
AFUE
—

The Crest with Hellcat FCB2500 fires 125 to 2500 MBH with 2400 MBH gross output and a 2087 MBH AHRI net rating — the entry of the FCB sizes Lochinvar's page copy rates at 20:1 turndown.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
150–3000 MBH
Output (max)
—
AFUE
—

The Crest with Hellcat FCB3000 fires 150 to 3000 MBH with 2883 MBH gross output and a 2507 MBH AHRI net rating, stepping air and vent to 10" on the Hellcat platform.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
200–3999 MBH
Output (max)
—
AFUE
—

The Crest with Hellcat FCB4000 fires 200 to 3999 MBH with 3843 MBH gross output and a 3342 MBH AHRI net rating at 96% thermal efficiency per its product page, with 12" air and vent.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
250–4999 MBH
Output (max)
—
AFUE
—

The Crest with Hellcat FCB5000 fires 250 to 4999 MBH with 4804 MBH gross output and a 4177 MBH AHRI net rating, stepping the Hellcat line to 6" pipe and 14" air and vent.

Natural gasPropaneHeating-only
CurrentSold in Canada
Input
300–6000 MBH
Output (max)
—
AFUE
—

The Crest with Hellcat FCB6000 tops the FCB range at 300 to 6000 MBH input with 5766 MBH gross output and a 5014 MBH AHRI net rating, on 6" pipe with a 3" gas inlet.

Natural gasPropaneHeating-only

Compare models in this series

Comparison of Lochinvar Crest FBN0751 and Lochinvar Crest FBN1001 and Lochinvar Crest FBN1251 and Lochinvar Crest FBN1501 and Lochinvar Crest FBN1751 and Lochinvar Crest FBN2001 and Lochinvar Crest FBN2501 and Lochinvar Crest FBN3001 and Lochinvar Crest FBN3501 and Lochinvar Crest FBN4001 and Lochinvar Crest FBN5001 and Lochinvar Crest FBN6001 and Lochinvar Crest FCB1000 and Lochinvar Crest FCB1500 and Lochinvar Crest FCB2000 and Lochinvar Crest FCB2500 and Lochinvar Crest FCB3000 and Lochinvar Crest FCB4000 and Lochinvar Crest FCB5000 and Lochinvar Crest FCB6000
SpecificationLochinvar Crest FBN0751Lochinvar Crest FBN1001Lochinvar Crest FBN1251Lochinvar Crest FBN1501Lochinvar Crest FBN1751Lochinvar Crest FBN2001Lochinvar Crest FBN2501Lochinvar Crest FBN3001Lochinvar Crest FBN3501Lochinvar Crest FBN4001Lochinvar Crest FBN5001Lochinvar Crest FBN6001Lochinvar Crest FCB1000Lochinvar Crest FCB1500Lochinvar Crest FCB2000Lochinvar Crest FCB2500Lochinvar Crest FCB3000Lochinvar Crest FCB4000Lochinvar Crest FCB5000Lochinvar Crest FCB6000
Heating input, minimum50 MBH50 MBH62.5 MBH60 MBH70 MBH80 MBH125 MBH150 MBH175 MBH333.3 MBH499.9 MBH600 MBH50 MBH60 MBH80 MBH125 MBH150 MBH200 MBH250 MBH300 MBH
Heating input, maximum750 MBH999 MBH1,250 MBH1,500 MBH1,750 MBH1,999 MBH2,500 MBH3,000 MBH3,500 MBH3,999 MBH4,999 MBH6,000 MBH999 MBH1,500 MBH1,999 MBH2,500 MBH3,000 MBH3,999 MBH4,999 MBH6,000 MBH
output-max————————————————————
afue————————————————————
turndown————————————————————
vent-max-3————————————————————
vent-max-2————————————————————
Weight with water1,768 lb1,838 lb1,975 lb2,307 lb2,458 lb2,570 lb3,600 lb3,900 lb4,600 lb5,200 lb5,900 lb6,900 lb1,838 lb2,307 lb2,570 lb3,600 lb3,900 lb5,200 lb5,900 lb6,900 lb

Read the full comparison: Lochinvar Crest FBN0751 vs FBN1001 →

Read the full comparison: Lochinvar Crest FBN1001 vs FBN1251 →

Read the full comparison: Lochinvar Crest FBN1501 vs FBN1751 →

Read the full comparison: Lochinvar Crest FBN2001 vs FBN2501 →

Read the full comparison: Lochinvar Crest FBN2501 vs FBN3001 →

Read the full comparison: Lochinvar Crest FBN5001 vs FBN6001 →

Read the full comparison: Lochinvar Crest FCB1000 vs FCB1500 →

Read the full comparison: Lochinvar Crest FCB1500 vs FCB2000 →

Read the full comparison: Lochinvar Crest FCB2000 vs FCB2500 →

Read the full comparison: Lochinvar Crest FCB3000 vs FCB4000 →

Read the full comparison: Lochinvar Crest FCB5000 vs FCB6000 →

Error codes and alerts

Crest (FB / Hellcat FCB) alerts

Manuals

Official documents

    Where ROMA provides on-site service

    On-site service is currently offered in Greater Vancouver, BC, including Vancouver, Burnaby, Richmond, Surrey, Coquitlam, North Vancouver, West Vancouver, New Westminster, Port Coquitlam, Port Moody, Delta, Langley, Maple Ridge, Abbotsford, Chilliwack, White Rock, Pitt Meadows, Tsawwassen, Anmore, Lions Bay, Belcarra, Bowen Island, Mission. Everything else on this site is reference information you can use anywhere in Canada.

    See all service areas

    Frequently asked questions

    What is the difference between the Crest FB and the Crest with Hellcat FCB?

    The Crest FB(N,L)0751-6001 is the original wave fire-tube line (with a RealTime O2 Feedback option), while the Crest with Hellcat FCB1000-6000 adds the Hellcat combustion system with RealTime O2 Trim, a 10" capacitive touchscreen and up to 150 equivalent feet of venting.

    Does Lochinvar make a "Crest FBK"?

    No. Lochinvar's official pages and manuals print FB(N,L)0751-FB(N,L)6001 (natural gas, propane and the FBD dual-fuel variant) and the Hellcat FCB1000(N,L)-FCB6000(N,L); the string "FBK" appears nowhere on lochinvar.com.

    What turndown do the Crest boilers have?

    The Crest I&O prints 15:1 on the 0751, 20:1 on the 1001/1251 and 2501-3501, 25:1 on the 1501-2001, 12:1 on the 4001 and 10:1 on the 5001-6001. The Hellcat page copy states 20:1 turndown for the FCB2500-6000 sizes.

    Talk to a boiler technician

    Describe what the boiler is doing and get a straight answer about the next step.

    On-site service in Greater Vancouver, BC. ROMA lists “Open 7 days” on its site; call to confirm same-day availability.

    Sources and verification

    Facts checked September 9, 2026. Last updated September 9, 2026. Technical reviewer: not yet assigned.

    CallEmailEstimate